Differences between revisions 9 and 10
Revision 9 as of 2016-02-21 14:03:38
Size: 585
Editor: NaokoOhishi
Comment:
Revision 10 as of 2016-02-21 14:04:19
Size: 620
Editor: NaokoOhishi
Comment:
Deletions are marked like this. Additions are marked like this.
Line 6: Line 6:
Each iKAGRA ETM suspension has 4 coils and 4 pico-motors connected. Each iKAGRA ETM suspension has 4 coils and 4 pico-motors (pitch:1-6, yaw:2-7, z:3-8, y:4-9) connected.

Mode Cleaner Suspensions

Each MC suspension has 4 coils and 2 pico-motors (pitch, yaw).

ETM

Each iKAGRA ETM suspension has 4 coils and 4 pico-motors (pitch:1-6, yaw:2-7, z:3-8, y:4-9) connected.

If the coil-magnet actuator seems to have a problem, please check 2 things.

1. Coil drivers in particular for Y-end had a loose connection with power line (-18V, -15V).

Please check the LED on coil driver. If the LED is out, try to fasten the power line.

2. Sometimes watchdog? system stop the output current from the coil driver in order to protect mechanical system.

PR3

KAGRA/Observation/iKAGRA/Manual/VIS (last edited 2016-03-24 17:13:06 by AyakaShoda)