9588
Comment:
|
12619
|
Deletions are marked like this. | Additions are marked like this. |
Line 8: | Line 8: |
* Schematic Diagram: [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11179|JGW-G2011179]] === Observing Run with PRFPMI for O3. === ||<#C6D6FE style="text-align:center; ">'''Bit'''||<#C6D6FE style="text-align:center; ">'''Description'''||<#C6D6FE style="text-align:center; ">'''0''' ||<#C6D6FE style="text-align:center; ">'''1'''||<#C6D6FE style="text-align:center; ">'''Comment'''||<#C6D6FE style="text-align:center; "> '''CBC''' ||<#C6D6FE style="text-align:center; "> '''BURST''' ||<#C6D6FE style="text-align:center; "> '''CW''' ||<#C6D6FE style="text-align:center; "> '''STOCH''' || || 0 || Odd Parity || - || - || This is not a data quality information. It is used for checking validation of DQV. || || || || || || 1 || Lock flag || Unlocked || Locked || This bit checks K1:GRD-IFO_OK. || CAT1 || CAT1 || CAT1 || || || 2 || SDF flag || Not nominal || Nominal || This bit checks K1:GRD-SYS_SDF_OK<<BR>>the setting of the IFO control is nominal or not. || || CAT2 || || || || 3 || Science mode || Not Science mode || Science mode || Science mode flag should be turned ON by manually && --(1th bit)-- 1st and 2nd bit is OK|| || || || || || 4 || OMC DCPD overflow || Overflow || No overflow || This bit checks OMC PD overflow || || CAT2 || || || || 5 || ETMX overflow || Overflow || No overflow || This bit checks ETMX coil out overflow. || || CAT2 || || || || 6 || ETMY overflow || Overflow || No overflow || This bit checks ETMY coil out overflow. || || CAT2 || || || || 7 || NO Stoch injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || CAT4 || || || || 8 || NO CBC injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || CAT4 || || || || 9 || NO Burst injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || CAT4 || || || || 10 || NO DET injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || CAT4 || || || || 11 || NO CW injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || CAT4 || || || || 12 || not assigned yet || || || || || || || || || 13 || not assigned yet || || || || || || || || || 14 || not assigned yet || || || || || || || || || 15 || not assigned yet || || || || || || || || == Data Category == === CBC === * CAT1: under discussion === Burst === * CAT1: Segments containing unlock, 30 seconds after lock and 30 second before unlock segments. * CAT2: Segments containing known abnormal situation. * CAT3: Segments containing unknown abnormal situation. * CAT4: Segments containing some injection signal. === CW === * CAT1: Same as CBC_CAT1 in LIGO. === Stoch === == LV Data Quality Flags == * [[https://www.gw-openscience.org/archive/dataset/O2_16KHZ_R1/|LIGO O2 Category Flags]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=G1900629&version=|LV O3 Online DQ]] * [[https://wiki.ligo.org/DetChar/DataQuality/O3Flags|LV O3 Low-latency, Offline DQ]] == Related Documents == * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9228|JGW-G1809228]] How to use SDF * [[https://docs.ligo.org/detchar/data-quality-report/|Data Quality Report]] * [[https://gracedb.ligo.org|GraceDB]] * [[https://ldas-jobs.ligo.caltech.edu/~rfisher/dqsegdb_doc/|DQSEGDB]] = Old information = == Online Data Quality Vector == * Channel name: '''K1:DET-DQ_STATE_VECTOR''' * Sampling rate: 16 Hz * Data type: Unsigned 32bit integer (FR_VECT_4U) * Schematic Diagram: [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11179|JGW-G2011179]] |
|
Line 62: | Line 117: |
== Data Category == === CBC === * CAT1: under discussion === Burst === * CAT1: Segments containing unlock, 30 seconds after lock and 30 second before unlock segments. * CAT2: Segments containing known abnormal situation. * CAT3: Segments containing unknown abnormal situation. * CAT4: Segments containing some injection signal. === CW === * CAT1: Same as CBC_CAT1 in LIGO. === Stoch === == LV Data Quality Flags == * [[https://www.gw-openscience.org/archive/dataset/O2_16KHZ_R1/|LIGO O2 Category Flags]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=G1900629&version=|LV O3 Online DQ]] * [[https://wiki.ligo.org/DetChar/DataQuality/O3Flags|LV O3 Low-latency, Offline DQ]] == Related Documents == * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9228|JGW-G1809228]] How to use SDF * [[https://docs.ligo.org/detchar/data-quality-report/|Data Quality Report]] * [[https://gracedb.ligo.org|GraceDB]] * [[https://ldas-jobs.ligo.caltech.edu/~rfisher/dqsegdb_doc/|DQSEGDB]] |
Data flag information
Contents
Online Data Quality Vector
Channel name: K1:DET-DQ_STATE_VECTOR
- Sampling rate: 16 Hz
- Data type: Unsigned 32bit integer (FR_VECT_4U)
Schematic Diagram: JGW-G2011179
Observing Run with PRFPMI for O3.
Bit |
Description |
0 |
1 |
Comment |
CBC |
BURST |
CW |
STOCH |
0 |
Odd Parity |
- |
- |
This is not a data quality information. It is used for checking validation of DQV. |
|
|
|
|
1 |
Lock flag |
Unlocked |
Locked |
This bit checks K1:GRD-IFO_OK. |
CAT1 |
CAT1 |
CAT1 |
|
2 |
SDF flag |
Not nominal |
Nominal |
This bit checks K1:GRD-SYS_SDF_OK |
|
CAT2 |
|
|
3 |
Science mode |
Not Science mode |
Science mode |
Science mode flag should be turned ON by manually && 1th bit 1st and 2nd bit is OK |
|
|
|
|
4 |
OMC DCPD overflow |
Overflow |
No overflow |
This bit checks OMC PD overflow |
|
CAT2 |
|
|
5 |
ETMX overflow |
Overflow |
No overflow |
This bit checks ETMX coil out overflow. |
|
CAT2 |
|
|
6 |
ETMY overflow |
Overflow |
No overflow |
This bit checks ETMY coil out overflow. |
|
CAT2 |
|
|
7 |
NO Stoch injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
8 |
NO CBC injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
9 |
NO Burst injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
10 |
NO DET injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
11 |
NO CW injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
12 |
not assigned yet |
|
|
|
|
|
|
|
13 |
not assigned yet |
|
|
|
|
|
|
|
14 |
not assigned yet |
|
|
|
|
|
|
|
15 |
not assigned yet |
|
|
|
|
|
|
|
Data Category
CBC
- CAT1: under discussion
Burst
- CAT1: Segments containing unlock, 30 seconds after lock and 30 second before unlock segments.
- CAT2: Segments containing known abnormal situation.
- CAT3: Segments containing unknown abnormal situation.
- CAT4: Segments containing some injection signal.
CW
- CAT1: Same as CBC_CAT1 in LIGO.
Stoch
LV Data Quality Flags
Related Documents
JGW-G1809228 How to use SDF
Old information
Online Data Quality Vector
Channel name: K1:DET-DQ_STATE_VECTOR
- Sampling rate: 16 Hz
- Data type: Unsigned 32bit integer (FR_VECT_4U)
Schematic Diagram: JGW-G2011179
Engineering Run with FPMI from 17th to 23rd Dec.
Bit |
Description |
0 |
1 |
Comment |
CBC |
BURST |
CW |
STOCH |
0 |
Odd Parity |
- |
- |
This is not a data quality information. It is used for checking validation of DQV. |
|
|
|
|
1 |
Lock flag |
Unlocked |
Locked |
This bit checks K1:GRD-LSC_LOCK_OK. |
CAT1 |
CAT1 |
CAT1 |
|
2 |
SDF flag |
Not nominal |
Nominal |
This bit checks the setting of the IFO control is nominal or not |
|
CAT2 |
|
|
3 |
Science mode |
Not Science mode |
Science mode |
Science mode flag should be turned ON by manually after human check |
|
|
|
|
4 |
AS17I/Q overflow |
Overflow |
No overflow |
This bit checks AS17I/Q overflow. (This bit will check OMC PD overflow for O3.) |
|
CAT2 |
|
|
5 |
ETMX overflow |
Overflow |
No overflow |
This bit checks ETMX coil out overflow. |
|
CAT2 |
|
|
6 |
ETMY overflow |
Overflow |
No overflow |
This bit checks ETMY coil out overflow. |
|
CAT2 |
|
|
7 |
NO Stoch injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
8 |
NO CBC injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
9 |
NO Burst injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
10 |
NO DET injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
11 |
NO CW injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
12 |
not assigned yet |
|
|
|
|
|
|
|
13 |
not assigned yet |
|
|
|
|
|
|
|
14 |
not assigned yet |
|
|
|
|
|
|
|
15 |
not assigned yet |
|
|
|
|
|
|
|
Engineering Run with MICH on the 13th July
Bit |
Description |
0 |
1 |
Comment |
CBC |
BURST |
CW |
STOCH |
0 |
Odd Parity |
- |
- |
This is not a data quality information. It is used for checking validation of DQV. |
|
|
|
|
1 |
Lock flag |
Unlocked |
Locked |
This bit checks K1:GRD-LSC_LOCK_OK. |
CAT1 |
CAT1 |
CAT1 |
|
2 |
SDF flag |
Not nominal |
Nominal |
This bit checks the setting of the IFO control is nominal or not |
|
CAT2 |
|
|
3 |
Science mode |
Not Science mode |
Science mode |
Science mode flag should be turned ON by manually after human check |
|
|
|
|
4 |
not used |
- |
- |
(This bit will check OMC PD overflow for O3.) |
|
|
|
|
5 |
MCE overflow |
Overflow |
No overflow |
This bit checks MCE coil out overflow. (It will check ETMX for O3.) |
|
CAT2 |
|
|
6 |
BS overflow |
Overflow |
No overflow |
This bit checks BS coil out overflow. (It will check ETMY for O3.) |
|
CAT2 |
|
|
7 |
NO Stoch injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
8 |
NO CBC injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
9 |
NO Burst injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
10 |
NO DET injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
11 |
NO CW injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
12 |
not assigned yet |
|
|
|
|
|
|
|
13 |
not assigned yet |
|
|
|
|
|
|
|
14 |
not assigned yet |
|
|
|
|
|
|
|
15 |
not assigned yet |
|
|
|
|
|
|
|
Engineering Run with X-arm on the 8th June
Bit |
Description |
0 |
1 |
Comment |
CBC |
BURST |
CW |
STOCH |
0 |
Odd Parity |
- |
- |
This is not a data quality information. It is used for checking validation of DQV. |
|
|
|
|
1 |
Lock flag |
Unlocked |
Locked |
This bit checks K1:GRD-LSC_LOCK_STATE_N (When GRD channel shows 31415, arm cavity is locked). |
|
CAT1 |
|
|
2 |
SDF flag |
Not nominal |
Nominal |
This bit checks the setting of the IFO control is nominal or not |
|
CAT2 |
|
|
3 |
Science mode |
Not Science mode |
Science mode |
Science mode flag should be turned ON by manually after human check |
|
|
|
|
4 |
not used |
- |
- |
(This bit will check OMC PD overflow for O3.) |
|
CAT2 |
|
|
5 |
MCE overflow |
Overflow |
No overflow |
This bit checks MCE coil out overflow. (It will check ETMX for O3.) |
|
CAT2 |
|
|
6 |
not used |
- |
- |
(This bit will check ETMY coil out overflow.) |
|
CAT2 |
|
|
7 |
NO Stoch injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
8 |
NO CBC injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
9 |
NO Burst injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
10 |
NO DET injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
11 |
NO CW injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
|
CAT4 |
|
|
12 |
not assigned yet |
|
|
|
|
|
|
|
13 |
not assigned yet |
|
|
|
|
|
|
|
14 |
not assigned yet |
|
|
|
|
|
|
|
15 |
not assigned yet |
|
|
|
|
|
|
|