メモ:ここには、地震研のDAQの情報を載せる。


DAQ of ERI

Computer

IP address

Name

Memo

172.16.32.xxx

PXI

for PD of the strainmeter. MAx: 24-bit 50kS/s. 1

172.16.32.208

cRIO01

for the environment monitor. Max:24-bit 12.5kS/s

172.16.32.209

cRIO02

for the environment monitor. Max:24-bit 12.5kS/s

172.16.32.218

cRIO03

for the environment monitor. Max:24-bit 12.5kS/s

172.16.32.219

Pxi Sub

Buffer1 :

172.16.32.202

KAGRA-DATA

Buffer2 :

172.16.32.210

NAS

Data server

172.16.32.201

KAGRA-CM

DAQ monitor

Data File Location

All files are under the "/YYYY/MM/DD/" directory and filename format is "YYMMDDhhmm.xxx", where .xxx is file extension.

Data Location

data type

Sampling Rate [Hz]

Unit Conversion factor

File extension

Comment

/NAS/cRIO01_data/

4byte Integer

200

1.25e-6 [V/count]

.AD0[0-7]

for Env. signal

/NAS/cRIO02_data/

4byte Integer

200

1.25e-6 [V/count]

.AD0[0-7]

for Env. signal

/NAS/cRIO03_data/

4byte Integer

200

1.25e-6 [V/count]

.AD0[0-15]

for Env. signal

/NAS/PXI_data/5000Hz

4byte Integer

5000

5.525e-9 [V/count]

.AD0[0-3]

for Main strainmeter signal

/NAS/PXI_data/50000Hz

4byte Integer

50000

5.525e-9 [V/count]

.AD0[0-3]

for Main strainmeter signal

/data1/PHASE/50000Hz

8byte float

200

1 [strain]

.PHASE
.STRAIN
.ZOBUBN
.SQRT

these are for the calculation of strain signal from the 50kHz PXI signal

/data2/CLIO/LIN

8byte float

200

1 [strain]

.LIN

calculated strain signal

/data2/CLIO/SHR

8byte float

200

1 [strain]

.SHR

calculated strain signal

Channel Name

Update Nov 15 2018, Miyo

Location

DAQ Name

File Location

File Extension

Data Type

Sampling Rate

Signal 

Calibration

X500

cRIO01

/NAS/cRIO01_data/

.AD00

4 Byte
Integer

200Hz

Temperature 

1.25e-6 [V/count], [Degree/V]

.AD01

4 Byte
Integer

200Hz

Humidity 

1.25e-6 [V/count], [%/V]

.AD02

4 Byte
Integer

200Hz

Pressure 

1.25e-6 [V/count], [Pa/V]

.AD03

4 Byte
Integer

200Hz

Vaccum 

1.25e-6 [V/count], ??? [Pa/V]

.AD04

4 Byte
Integer

200Hz

PXI01 Power for 3.3V 

1.25e-6 [V/count]

.AD05

4 Byte
Integer

200Hz

PXI01 Power for 5.0V 

1.25e-6 [V/count]

.AD06

4 Byte
Integer

200Hz

PXI01 Power for +12V 

1.25e-6 [V/count]

.AD07

4 Byte
Integer

200Hz

PXI01 Power for -12V

1.25e-6 [V/count]

PXI01

/NAS/PXI_data/5000Hz
or
/NAS/PXI_data/50000Hz

CH0

PD1

CH1

PD2

CH2

Laser Amplitude

CH3

Laser Absorption

Location

DAQ Name

File Location

File Extension

Data Type

Sampling Rate

Signal 

Calibration

X2000

cRIO02

/NAS/cRIO02_data/

.AD00

4 Byte
Integer

200Hz

Temperature 

1.25e-6 [V/count], [Degree/V]

.AD01

4 Byte
Integer

200Hz

Humidity 

1.25e-6 [V/count], [%/V]

.AD02

4 Byte
Integer

200Hz

Pressure 

1.25e-6 [V/count], [Pa/V]

.AD03

4 Byte
Integer

200Hz

Vaccum 

1.25e-6 [V/count]

.AD04

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD05

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD06

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD07

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

Location

DAQ Name

File Location

File Extension

Data Type

Sampling Rate

Signal 

Calibration

X1500

cRIO03

/NAS/cRIO03_data/

.AD00

4 Byte
Integer

200Hz

Trillium240 velocity EW 

1.25e-6 [V/count]

.AD01

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD02

4 Byte
Integer

200Hz

Trillium240 velocity NS 

1.25e-6 [V/count]

.AD03

4 Byte
Integer

200Hz

Trillium240 velocity UD 

1.25e-6 [V/count]

.AD04

4 Byte
Integer

200Hz

Trillium240 position EW 

1.25e-6 [V/count]

.AD05

4 Byte
Integer

200Hz

Trillium240 position NS 

1.25e-6 [V/count]

.AD06

4 Byte
Integer

200Hz

Trillium240 position UD 

1.25e-6 [V/count]

.AD07

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

.AD08

4 Byte
Integer

200Hz

CMG3T velocity EW 

1.25e-6 [V/count]

.AD09

4 Byte
Integer

200Hz

CMG3T velocity NS 

1.25e-6 [V/count]

.AD10

4 Byte
Integer

200Hz

CMG3T velocity UD 

1.25e-6 [V/count]

.AD11

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

.AD12

4 Byte
Integer

200Hz

CMG3T position EW 

1.25e-6 [V/count]

.AD13

4 Byte
Integer

200Hz

CMG3T position NS 

1.25e-6 [V/count]

.AD14

4 Byte
Integer

200Hz

CMG3T position UD 

1.25e-6 [V/count]

.AD15

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]


UPS

場所

用途

本体型番(バッテリー)

交換日時

北部会館

データ処理計算機用

BY80S(BYB80S)

---

CLIO坑内

---

---

---

GIF坑内

---

---

---