Differences between revisions 64 and 89 (spanning 25 versions)
Revision 64 as of 2018-11-15 15:17:22
Size: 1999
Editor: KousekiMiyo
Comment:
Revision 89 as of 2018-11-20 07:43:38
Size: 1115
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
<<TableOfContents(3)>>
= Environmental Sensors =
== Overview ==
{*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。

== Sensors List ==
|| || '''Sensor''' || '''Use''' || '''Spec''' ||
'''DAQ<<FootNote(More detail information about cRIO is [[KAGRASubgroupsGIFDAQ|here]].)>> ''' || ''' Purpose ''' ||
||<|3> Air Environmental Sensor<<BR>>[[KAGRA/Subgroups/GIF/EM/AirEnvironmentalSensors|(Detail)]] ||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS ||
= Environment Sensors =
 * {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。
 * {*} 配置図を載せる。
||<#F0F0FF> ||<#F0F0FF>'''Sensor''' ||<#F0F0FF>'''Purpose''' ||<#F0F0FF>'''Noise Level''' ||<#F0F0FF>'''DAQ<<FootNote(More detail information about cRIO is [[KAGRA/Subgroups/GIF/DAQ|here]].)>> ''' ||
||<|3> '''[[KAGRA/Subgroups/GIF/EM/AirEnvironmentSensors|Air Environment Sensor]]''' ||<|2>HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS ||
Line 10: Line 7:
|| [[https://www.vaisala.com/sites/default/files/documents/PTB110%20User%20Guide%20in%20English.pdf|(Manual)]] PTB110(Vaisala) || Pressure || || cRIO, KAGRA CDS ||
||<|2> KAGRA Seismometer || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || || KAGRA CDS ||
|| [[https://www-iuem.univ-brest.fr/pops/attachments/1489|(Manual)]] Trillium Compact || seismic || || KAGRA CDS ||
||<|2> GIF Seismometer || [[https://www.passcal.nmt.edu/webfm_send/220|(Manual)]] Trillium 240 || seismic || || cRIO ||
|| [[https://www.guralp.com/documents/MAN-030-0001.pdf|(Manual)]] CMG3T || seismic || || cRIO ||

== Deployment ==

 {*} 配置図を載せる。

== Circuit ==

 {*} アンプの回路図、Dsubの配線図等のJGWのリンクを載せる。

== Calibration ==
cRIO01 500m, y[V]がADの電圧値。上からAD00,01,02,03
{{{
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=-y[V]/5*100/2
p[hPa]=-y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]
}}}
cRIO02 2000m
{{{
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=y[V]/5*100/2
p[hPa]=y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]
}}}

== Reference ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9269| Envrionmental Air Sensors]]
|| PTB110(Vaisala) || Pressure || || cRIO, KAGRA CDS ||
||<|2> '''[[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/PEM/Channels#Seismometer|KAGRA Seismometer]]'''|| Trillium 120QA|| seismic || || KAGRA CDS ||
|| Trillium Compact || seismic || || KAGRA CDS ||
||<|2> '''[[KAGRA/Subgroups/GIF/EM/GIFseismometer|GIF Seismometer ]]''' || Trillium 240 || seismic || || cRIO ||
|| CMG3T || seismic || || cRIO ||
== Scope ==
 1. ~+Characterization of __strainmeter__ and __KAGRA interferometer__ in terms of low frequency especially below 1Hz +~

Environment Sensors

  • {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。

  • {*} 配置図を載せる。

Sensor

Purpose

Noise Level

DAQ1

Air Environment Sensor

HMP155(Vaisala)

Temperature

cRIO, KAGRA CDS

Humidity

cRIO, KAGRA CDS

PTB110(Vaisala)

Pressure

cRIO, KAGRA CDS

KAGRA Seismometer

Trillium 120QA

seismic

KAGRA CDS

Trillium Compact

seismic

KAGRA CDS

GIF Seismometer

Trillium 240

seismic

cRIO

CMG3T

seismic

cRIO

Scope

  1. Characterization of strainmeter and KAGRA interferometer in terms of low frequency especially below 1Hz


  1. More detail information about cRIO is here. (1)

KAGRA/Subgroups/GIF/EM (last edited 2018-11-20 07:43:38 by KousekiMiyo)