Line 48: Line 48:
   * NoEMI    * NoEMi
Line 50: Line 50:
 * Visitors from LV  * Visitors from LVK
Line 55: Line 55:
   * Fujikawa, TNTanaka 11/24-12/3
Line 73: Line 74:
    * 週末のFPMIとPEMのcoherenceを見ていった。
    * 11HzのEXCにmagとの相関が見えたのですが、みに行った時間にはなかった、lockとの関係がある?
    * Pcal RxPD 1.3HzはETMYのgasが励起していて、それが影響していた可能性がある。->long oplevとして見えた。
    * 24Hzはrack noise
    * Calculated the coherence between DARM displacement and PEM channels for long locked data (>1h, 500average)
    * We can see the coherence between DARM and EXC MAG Y at 11Hz, but we couldn't see peak when he went to end station, coincidence with LOCK status?
    * Coherence with PCal RxPD at 1.3Hz, ETMY gas excitation made the large oscillation, Pcal detected as long oplev
    * 24Hz is serious rack noise
Line 79: Line 80:
    * 60Hz EXC magが大きい、GNDが汚れている可能性が高い
    * PSL acousticは複数micを置いて場所を見る。
    * ~110Hzはlaser amp
    * The 60Hz peak of the EXC MAG is larger than other MAG, this imply the dark GND at Xend station
    * It turned out acoustic noise search inside the PSL is difficult, we prepared the multiple microphone and see the data at the same time.
    * laser amp made the ~110Hz vibration and injected to the noise, similar path with 24V power supply vibration(white rack)
Line 83: Line 84:
    * Priorityを決める、Identifyとhuntingはちがう。     * We need to classify the Priority to the noises, it is different between identification and hunting
Line 88: Line 89:
     * 42Hzパイロンの共振
     * 44Hz 気まぐれcompressor
     * 42Hz is resonant frequency of the pylon
     * 44Hz Whimsical compressor -> checked by them
Line 91: Line 92:
     * 54.125Hz きまぐれcompressor
     * 58音?
     * acoustic injectionで盛り上がるpeakがある。散乱光の影響か?
     * IXCとDARMのcoherenceを取れるdataが木曜日の夜にすこしだけある。
     * center areaのmicとDARMに7Hz coherence、エンドには出ない
     * ITMX MN Pとcoherence <20Hz
     * TM oplev定盤に置いたACCとDARMにcoherenceがある、46Hz、いいヒント
     * MICとITMX PEMのcoherence、46Hzにmic vs TM oplev、lengthにあるかも
     * プシュー有り無しで比較したい。
     * compressor, 2分静か、30秒かたかた、10分、プシュー
     * 54.125Hz Whimsical compressor -> checked by them
     * 58 sound origin?
     * Some peaks were grow up by the acoustic injection, due to the scattered light?
     * There is data which can take coherence between DARM and accelerometers which were placed in the IXC chamber
     * There is some coherence between DARM and MIC at center area, there is no coherence with end mic
     * There is coherence with ITMX MN P <20Hz
     * There is coherence at 46Hz between DARM and ACC at the TM oplev table, this is some hint for 46Hz noise
     * Also MIC at 46Hz
     * We want to check the condition with various air compressor

Minute of PEM meeting (English)

  • Date: 2019/11/05 17:00-18:00(JST)
  • Attend:Yokozaqwa, TNTanaka, Fujikawa, Ohkawa, Washimi, Mori, Kozakai, Yamada, Akutsu, Kaihotsu

Agenda

  • General issue
    • Interferometer status
      • Now, we can lock the interferometer stably
      • ISS(Intensity Stabilization System) was implemented, better sensitivity
      • Long silent run at 2nd Nobember (klog11312)

      • See the detail in url

      • Silent run -> Some excitation(including calibration line) -> PEM injection -> Hardware injection

  • PTEP paper
    • [kagra 03133]
    • KAGRA Overview papers
    • Overview of KAGRA : (3) Detchar, calibration, physical environment, data quality
  • Next F2F meeting
    • RESCEU
    • 4th and 5th Dec., 2019
    • 1 slot Washimi-san will have a talk
    • If you plan to write master/doctor thesis, please let me know
      • Master thesis : TTanaka(ICRR)
  • Chrome Book project (Portable PEM researcher)
  • PEM injection
    • Shaker injection1 (TTanaka, Yokozawa)
    • Shaker injection2 (Okutomi, Fabian) -> After O3

    • acoustic injection (TTanaka, Yokozawa)
    • magnetic field injection (Niigata Tanaka, Fujikawa, Yokozawa)
    • RF injection (TTanaka, Washimi) -> After O3

  • Weekly PEM measurement
    • Friday is weekly PEM measurement
    • Understanding the effect of the instruments, search the origin of noise, and so on
    • Tentative : New vacuum pump, 18V DC noise(24Hz), Cryochamber vibration(46Hz), FFU, Noise search
  • Database for the KAGRA characteristic lines
  • Visitors from LVK
    • Anamaria from Livingston : 18 - 29 Nov.
    • Federico, Irene, Camilla (input optics) + Francesca from Virgo : 11/18-12/7 (2 weeks@KAGRA, 1 weeks@NAOJ)
      • We will ask them about the status talk of the commissioning break and reviewer
    • LVK PEM meeting (11/26)

    • Fujikawa, TNTanaka 11/24-12/3
  • Each progress
    • Yokozawa
      • Current serious noises
        • 24Hz noise (100V AC + AA?)
          • We connect/disconnect the GND JP in the AA chassis, but could not understand
        • MICH control noise
          • Add the noise projection of the MICH control noise
        • Coherent with ITMX MN YAW
          • Wait for the noise budget of the Type-A control
        • Coherence with ITMY TM PIT
          • Wait for the noise budget of the Type-A control
      • Daily summary page
        • Update PEM, VIS, FPMI part
    • Washimi
      • Summary of coherence study between PEMs and DARM displacement
        • Calculated the coherence between DARM displacement and PEM channels for long locked data (>1h, 500average)

        • We can see the coherence between DARM and EXC MAG Y at 11Hz, but we couldn't see peak when he went to end station, coincidence with LOCK status?
        • Coherence with PCal RxPD at 1.3Hz, ETMY gas excitation made the large oscillation, Pcal detected as long oplev
        • 24Hz is serious rack noise
        • 44,45Hz Compressor or FFU?
        • Compressor sound make44Hz, 46Hz and 56Hz -> stop during observation, check the coherence with FPMI signal

        • The 60Hz peak of the EXC MAG is larger than other MAG, this imply the dark GND at Xend station
        • It turned out acoustic noise search inside the PSL is difficult, we prepared the multiple microphone and see the data at the same time.
        • laser amp made the ~110Hz vibration and injected to the noise, similar path with 24V power supply vibration(white rack)
        • 840Hz IMC refl
        • We need to classify the Priority to the noises, it is different between identification and hunting
    • Washimi, Yamada, TTanaka
      • IXC vibration -> See the Yamada-san's slide

        • Identify the origin of the frequency noise
        • 42Hz is resonant frequency of the pylon
        • 44Hz Whimsical compressor -> checked by them

        • 46.125Hz
        • 54.125Hz Whimsical compressor -> checked by them

        • 58 sound origin?
        • Some peaks were grow up by the acoustic injection, due to the scattered light?
        • There is data which can take coherence between DARM and accelerometers which were placed in the IXC chamber
        • There is some coherence between DARM and MIC at center area, there is no coherence with end mic
        • There is coherence with ITMX MN P <20Hz

        • There is coherence at 46Hz between DARM and ACC at the TM oplev table, this is some hint for 46Hz noise
        • Also MIC at 46Hz
        • We want to check the condition with various air compressor
    • Kozakai
      • Trigger analysis with silent run
      • glitch plotがautoで走ったので、Yuzu summary pageを見てみてください。
      • glitch plot catalog
      • 磁束計で見えているのと地震計で見えているものがある、何処のsuspensionが影響が大きいかなどもわかると思う。
      • Fabianがコメントしていた、oplev jumpは影響あるか?->あとでみてみる

    • TTanaka(ICRR), Washimi, TTanaka(Niigata), Yamada
      • Acoustic injection with FPMI
    • Mori, Nakayama
      • Vacuum pump vibration
      • 6箇所のvacuum pump(dry、turbo)を止めた、ionは止めていない、観測中もionだけは着けておくと思われる。
      • turbo pump on/offでの振動の比較
      • Pressureは2倍になったが、影響はなさそう、outor gasは少ないと思われる。
      • 振動が少ないポンプ
      • ポンプ由来の振動ピークと音響ピークを同定できた
      • 200Hzがfloorがすこしちがう、OFFの方が多いから何かhintになると思う。214と216Hz。253Hzはonoff関係なく存在した。
      • chiller付きのpumpではない
    • Fujikawa, Mori
      • fujimopy PEMmtg_191105fmpy.pdf

        • 装置オンオフのpeak identification
        • diagguiからもできるようにした。
        • ICRR accountが来たのでhtmlを開始する。40Hz->11Hzか?

      • Line amplitude web page
    • Fujikawa, Washimi
      • Lock loss study
        • root histogram-> gauss fitting and check the significance->lock lossの原因を簡単に判明?

        • acoustic injectionのlock loss->pulse的なのか、振動が強くなって行ったのか?

        • FPMIのロックロス
    • TTanaka(Niigata)
      • Preparation of the coil
      • 24Hz noise situation
      • PEM injection用コイルドライバーの作成
      • 卒論の議論とMAG injection
    • etc