Differences between revisions 5 and 6
Revision 5 as of 2019-11-09 03:43:10
Size: 6993
Comment:
Revision 6 as of 2019-11-09 03:43:29
Size: 6998
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
== Minute of PEM meeting (English) == == Minute of PEM meeting (English ver.) ==

Minute of PEM meeting (English ver.)

  • Date: 2019/11/05 17:00-18:00(JST)
  • Attend:Yokozaqwa, TNTanaka, Fujikawa, Ohkawa, Washimi, Mori, Kozakai, Yamada, Akutsu, Kaihotsu

Agenda

  • General issue
    • Interferometer status
      • Now, we can lock the interferometer stably
      • ISS(Intensity Stabilization System) was implemented, better sensitivity
      • Long silent run at 2nd Nobember (klog11312)

      • See the detail in url

      • Silent run -> Some excitation(including calibration line) -> PEM injection -> Hardware injection

  • PTEP paper
    • [kagra 03133]
    • KAGRA Overview papers
    • Overview of KAGRA : (3) Detchar, calibration, physical environment, data quality
  • Next F2F meeting
    • RESCEU
    • 4th and 5th Dec., 2019
    • 1 slot Washimi-san will have a talk
    • If you plan to write master/doctor thesis, please let me know
      • Master thesis : TTanaka(ICRR)
  • Chrome Book project (Portable PEM researcher)
  • PEM injection
    • Shaker injection1 (TTanaka, Yokozawa)
    • Shaker injection2 (Okutomi, Fabian) -> After O3

    • acoustic injection (TTanaka, Yokozawa)
    • magnetic field injection (Niigata Tanaka, Fujikawa, Yokozawa)
    • RF injection (TTanaka, Washimi) -> After O3

  • Weekly PEM measurement
    • Friday is weekly PEM measurement
    • Understanding the effect of the instruments, search the origin of noise, and so on
    • Tentative : New vacuum pump, 18V DC noise(24Hz), Cryochamber vibration(46Hz), FFU, Noise search
  • Database for the KAGRA characteristic lines
  • Visitors from LVK
    • Anamaria from Livingston : 18 - 29 Nov.
    • Federico, Irene, Camilla (input optics) + Francesca from Virgo : 11/18-12/7 (2 weeks@KAGRA, 1 weeks@NAOJ)
      • We will ask them about the status talk of the commissioning break and reviewer
    • LVK PEM meeting (11/26)

    • Fujikawa, TNTanaka 11/24-12/3
  • Each progress
    • Yokozawa
      • Current serious noises
        • 24Hz noise (100V AC + AA?)
          • We connect/disconnect the GND JP in the AA chassis, but could not understand
        • MICH control noise
          • Add the noise projection of the MICH control noise
        • Coherent with ITMX MN YAW
          • Wait for the noise budget of the Type-A control
        • Coherence with ITMY TM PIT
          • Wait for the noise budget of the Type-A control
      • Daily summary page
        • Update PEM, VIS, FPMI part
    • Washimi
      • Summary of coherence study between PEMs and DARM displacement
        • Calculated the coherence between DARM displacement and PEM channels for long locked data (>1h, 500average)

        • We can see the coherence between DARM and EXC MAG Y at 11Hz, but we couldn't see peak when he went to end station, coincidence with LOCK status?
        • Coherence with PCal RxPD at 1.3Hz, ETMY gas excitation made the large oscillation, Pcal detected as long oplev
        • 24Hz is serious rack noise
        • 44,45Hz Compressor or FFU?
        • Compressor sound make44Hz, 46Hz and 56Hz -> stop during observation, check the coherence with FPMI signal

        • The 60Hz peak of the EXC MAG is larger than other MAG, this imply the dark GND at Xend station
        • It turned out acoustic noise search inside the PSL is difficult, we prepared the multiple microphone and see the data at the same time.
        • laser amp made the ~110Hz vibration and injected to the noise, similar path with 24V power supply vibration(white rack)
        • 840Hz IMC refl
        • We need to classify the Priority to the noises, it is different between identification and hunting
    • Washimi, Yamada, TTanaka
      • IXC vibration -> See the Yamada-san's slide

        • Identify the origin of the frequency noise
        • 42Hz is resonant frequency of the pylon
        • 44Hz Whimsical compressor -> checked by them

        • 46.125Hz
        • 54.125Hz Whimsical compressor -> checked by them

        • 58 sound origin?
        • Some peaks were grow up by the acoustic injection, due to the scattered light?
        • There is data which can take coherence between DARM and accelerometers which were placed in the IXC chamber
        • There is some coherence between DARM and MIC at center area, there is no coherence with end mic
        • There is coherence with ITMX MN P <20Hz

        • There is coherence at 46Hz between DARM and ACC at the TM oplev table, this is some hint for 46Hz noise
        • Also MIC at 46Hz
        • We want to check the condition with various air compressor
    • Kozakai
      • Trigger analysis with silent run
      • Auto process was run when we can take the silent run, the glitch plots were generated for the long silent run, please check the Yuzu summary page
      • glitch plot catalog
      • There is coincidence between large glitch and magnetometers and/or seismometers, suspension jump.
      • Fabian requested that there is coincidence between OL jump and glitch -> check later

    • TTanaka(ICRR), Washimi, TTanaka(Niigata), Yamada
      • Acoustic injection with FPMI
      • No report in this meeting
    • Mori, Nakayama
      • Vacuum pump vibration
      • They stopped six vacuum pump(dry、turbo) at the center area(BS) at last Friday, they didn't stop the ion pumps, ion pumps will not be stopped during observation.
      • Compared the vibration between turbo pump on and off
      • Pressure value became twice worse, but there is no serious problem, this imply the outer gas is not so large
      • New low vibration vacuum pump characterization
      • They summarized the vibration and sound from the vacuum pumps
      • The behavior of the noise floor at 200Hz is interested、the floor in case of the OFF is larger than in case of the ON, 214Hz and 216Hz
    • Fujikawa, Mori
      • fujimopy
        • Peak identification for the two cases (ex: pump on/off)
          • Average is important to reduce the statistical error
          • Available from the diaggui
        • html viewpage in the ICRR computer : change 40-50Hz to 7-11Hz?
      • Line amplitude web page
    • Fujikawa, Washimi
      • Lock loss study
        • root histogram-> gauss fitting and check the significance->Easy identification of the lock loss

        • Lock loss due to the IXC acoustic injection->pulse like injection or excitation?

        • Stat the investigation for the lock loss of the FPMI
    • TTanaka(Niigata)
      • Preparation of the coil
      • 24Hz noise situation
      • Made the coil driver for the PEM injection
      • Discussed about his thesis and MAG injection
    • etc

KAGRA/Subgroups/PEM/Meeting/191105/MinuteEN (last edited 2019-11-09 03:43:29 by TakaakiYokozawa)