== Weekly PEM meeting == * 2020/03/20(Tue) 14:00-(JST) * Regular meeting meeting (Japanese) * Web meeting with Zoom2 ([[https://zoom.us/j/6676627462|Zoom2]]) * member : Nagano, Ohkawa, Takano, RTakahashi, Washimi, Tomaru, Kozakai, Yokozawa ==== General issue ==== * Interferometer status * 3/10 - commissioning break started * Noise projection * Hammering test (Sat. and Sun. morning time) * DRFPMI lock trial * Noise budget was (almost) completed * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13600|klog13600]] * Below 70 Hz : Type-A control noise * 100 - 200 : Actuator DAC noise(?) * 200 - 400 : Acoustic noise around IMM area (?) * Above 400 Hz : Shot noise, Laser noise(Intensity, frequency) * PEM tasks in March * [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/PEM/MAR2020|task list]] * PRM booth MICを常設にしませんか? (IOO1 BNC ch11かch12で) ==== Each progress ==== * Discussion about the list of the general issue (Yokozawa) * Acoustic injection and hammering test result (Washimi) * Data and Results list : [[KAGRA/Subgroups/PEM/PEMinjection/O3]] * KAGRA Noise INJection Analizer; NINJA : [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11564|JGW-T2011564]] * Plan of the lock loss study (Fujikawa) ==== Minutes ==== * Yokozawa will make the todo list for Saturday and Sunday hammering test * Check again the IMC gate valve (Open and Close lock trial with close the gate valve, ...) * Discussed about the offline subtraction (including to online?) * Hammering test and acoustic injection to REFL table area * There is coherence with the DARM, PRCL. Not so in CARM, MICH * Laser fluctuation * The hammering effect is largest around IMC bellows. And effect became smaller when we hammered far from MCF chamber. * The effect of the hammering to MCF chamber itself is not so large * From the noise projection to the accelerometer, the dominant vibration source would come from acoustic * We turned out 500Hz may come from REFL table, but we didn't identify which optic may make * NINJA * Only work in the k1ctr7 (Environmental dependence) * Investigation the scattering light effect by injecting the low frequency fluctuation * So called shoulder noise * [[https://logbook.virgo-gw.eu/virgo/?r=38028|Virgo work by Nagano-san]] * Including to scheduling * camera setup inside the vacuum