Differences between revisions 4 and 5
Revision 4 as of 2023-08-18 10:04:51
Size: 5309
Comment:
Revision 5 as of 2023-08-18 10:06:49
Size: 5356
Comment:
Deletions are marked like this. Additions are marked like this.
Line 19: Line 19:
   * Deep Clean member
   * Kamiel and Anoop

Weekly PEM meeting

General announcement

  • New KSC chair and vice-chair
    • Masaki Ando
    • Ray-Kuang Lee and Sachiko Kuroyanagi
  • Open the registration LVK meeting@Toyama
    • Poster abstract submission
      • 27th August
    • 2023/09/11-15
    • Including the F2F meeting
    • url

    • Welcome the visitor
      • Deep Clean member
      • Kamiel and Anoop
  • KAGRA visiting plan
    • If you want to visit Kamioka, please contact to Yokozawa

Meeting and Conference issue

  • LVK meeting at Toyama
    • 11-14 September 2023
    • KAGRA F2F meeting on Sep. 15
  • JPS meeting (Tohoku U)
    • 16-19 September 2023
    • Presentation about PEM
      • Yokozawa (Status)
      • Washimi (Noise hunting)
      • Hoshino (Seismic forecast)
  • Other meetings url

If you have some presentation about PEM related, please contact to me.

Business travel (except for conferences)

  • To Kamioka
    • Hoshino(8/8 - 10)
  • From Kamioka
    • No

General issue

  • Cooling down
    • EX : Achieved 20 K in IM
      • Monitored the height by MNV oplev and TCam
        • The SUM value of MNV oplev decreased with temperature, that turned out the clipping by the viewport of radiation shield klog26232

        • Now recovered, but SUM decreasing continued
      • Serious frosting and finesse down detected
        • Turned on the heater at IM, after increasing 30 K, the finesse recovered
        • Still some frosting at AR side from picture klog26336 and oplev sumklog26308

        • During PRFPMI locked, the temperature of IM gradually increasedklog26358.

    • IX, IY, EY ongoing : about 110 K in IM (2023/08/18)
      • Temperature change url

  • Vacuum level trouble
    • EX : performance of one cryocooler became worse
      • No serious damage to the test mass
      • Plan to restart it around LVK meeting(September)
    • Yarm
      • Y-21 vacuum trouble
        • Now, by turning on the TMP, keep good vacuum level
  • New high power laser replacement
    • Temperature drift would be smaller by tuning the temperature control
    • But if we increased the output laser power from PSL room, IMC cannot be locked.
    • Now operating the current old laser
  • Alignment inside the PSL room
    • PMC alignment done(No so serious change)
    • GR alignment done (Increased the beam power)
  • Interferometer operation
    • After checking the POP and REFL table again, and found one BS flipped.
      • Then, PRFPMI RF became more stable (One night lock)
  • New IP control
    • Ongoing
  • PEM tasks
    • Outside magnetometer
      • DAQ system trouble? Washimi-san sent to company
    • Acoustic noise at OMC
      • Re-cabling for OMC speaker
    • AC power check at Yend
      • SUM value of the MNV oplev decreased
      • No problem in AC power supplying

Jurnal paper issue

Details are here!

  • Micro seismic analysis (Hoshino)
  • ICRC Proceedings
  • Acoustic reverberation time paper (Washimi+, Sato?)
    • Suspend
    • Re-measurement before O4?
  • TCam paper
    • Writing ongoing

Preparation for O4b

  • Check the seismic motion around mozumi area
    • Daytime ground motion
    • It may appeared in DARM sensitivity (SR3?)
  • Schumann resonance measurement
    • Ongoing
  • Investigation of the PEM injection
    • Magnetic injection
      • After O4a?
  • Voltmeter preparation
    • AC power monitor installation
    • DC power monitor installation
  • After O4
    • RF monitor with mokugo
    • Tiltmeter
    • RI detector
    • Newtonian noise
  • Discussion with DET members
    • Daily summary page PEM

Progress report

  • Yuzurihara
    • Pastavi
    • Data Quality Report slide

    • Data quality evaluation
  • Hoshino
    • Seismic motion analysis
  • Sato
    • Sound source analysid
  • Miyamoto
    • Weather analysis
  • Takatani
    • Applying the deepclean
    • Calculation of Schumann resonance
  • Kume
    • PR3 line injection klog25670

    • Noise subtraction
  • Nishizawa
    • Water newtonian noise
    • Magnetic field analysis
  • Washimi
    • Magnetometer DAQ status
  • Yokozawa
    • AC power monitor

Place for memo

KAGRA/Subgroups/PEM/Meeting/230818/Agenda (last edited 2023-08-18 10:06:49 by TakaakiYokozawa)