Differences between revisions 1 and 3 (spanning 2 versions)
Revision 1 as of 2018-05-24 12:04:27
Size: 472
Editor: EnzoTapia
Comment:
Revision 3 as of 2019-07-19 15:56:04
Size: 962
Editor: AyakaShoda
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
**AutoMeasurement data set.  This is just a proposal yet.
Line 3: Line 3:
The data set is stored in /users/VIS/(Suspension_Name)/AutoMeasurement
Example: /users/VIS/SR3/AutoMeasurement
= AutoMeasurement data set =
The data set is stored in /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/. <<BR>>
The directory structure is as following:
Line 6: Line 7:
The main measurement scripts are stored in ./script
The template files are stored in ./templates
The measured data is stored in ./data.
{{attachment:image.png|alt text|width=100 height=150}}
Line 10: Line 9:
* How to use
1. Go to a directory /users/VIS/SR2/AutoMeasurement/script.
2. run the command for IM TF measurement:
./run_measurement_IM
3. The measurement will start from IM Len.
{{{#!wiki caution
'''DO NOT STORE YOUR CUSTOMIZED DATA IN THE AUTO-MEASUREMENT DIRECTORY'''

The data in this directory should follow the template.
}}}


= How to use =
 1. Go to a directory /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/(Type)/scripts/(TF or Spectra)/
 2. run the command (Example: ./run_measurement_IM)
 3. The xml data is stored in the directory /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/(Type)/(OPTIC)/(TF or Spectra)/Measurements/(YYYYMMDD)/ together with the
 4. The xml data and summary plot are also copied in the directory /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/(Type)/(OPTIC)/(TF or Spectra)/Measurements/latest/ and the older data in the latest folder is deleted.
  • This is just a proposal yet.

AutoMeasurement data set

The data set is stored in /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/.
The directory structure is as following:

DO NOT STORE YOUR CUSTOMIZED DATA IN THE AUTO-MEASUREMENT DIRECTORY

The data in this directory should follow the template.

How to use

  1. Go to a directory /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/(Type)/scripts/(TF or Spectra)/
  2. run the command (Example: ./run_measurement_IM)
  3. The xml data is stored in the directory /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/(Type)/(OPTIC)/(TF or Spectra)/Measurements/(YYYYMMDD)/ together with the
  4. The xml data and summary plot are also copied in the directory /kagra/Dropbox/Subsystems/VIS/AutoMeasurement/(Type)/(OPTIC)/(TF or Spectra)/Measurements/latest/ and the older data in the latest folder is deleted.

KAGRA/Subgroups/VIS/OpsManual/AutoMeasurement (last edited 2019-08-08 10:12:18 by AyakaShoda)