Differences between revisions 25 and 26
Revision 25 as of 2019-11-12 18:07:06
Size: 1831
Comment:
Revision 26 as of 2019-11-12 18:18:53
Size: 1924
Comment:
Deletions are marked like this. Additions are marked like this.
Line 25: Line 25:

=== Other related entries ===
[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8082|8082]]

SR3

Describe KAGRA/Subgroups/VIS/OpsManual/FishingRods here.

This page describes the status of the fishing rods.

Beam splitter

Top filter

  • At 25 ºC it's possible to use the fishing rod to set the keystone at nominal position (8125).

  • at 24.5 ºC or lower it's not (8645, 11465).

  • Range: from -2500 µm to +4900 µm in the LVDT and from -1,400,000 to +1,400,000 steps in the stepper motor (7694). What was the temperature that day?

Standard Filter

  • It's been at its lowest position since the temperature was 25 ºC. We set the keystone to 488 µm and couldn't move it down more (8125, 8645).

  • Range: from -700 µm to +700 µm in the LVDT and from -870,000 to +835,000 steps in the stepper motor (3558). What was the temperature that day?

Bottom filter

  • This fishing rod didn't seem to have any problems before but we haven't tried to use it at every temperature condition we've had.
  • Range: from -1000 µm to +1800 µm in the LVDT and from -746,000 to +746,000 steps in the stepper motor (3280).What was the temperature that day?

SR2

Stardard filter

Range: from -750 µm to 1000 µm in the LVDT and from 300,000 to 1,000,00 steps in the stepper motor (4431).

Bottom filter

Range: from -500 µm to 600 µm in the LVDT and from -550,000 to -250,000 (4430).

8082

SR3

KAGRA/Subgroups/VIS/OpsManual/FishingRods (last edited 2020-09-18 10:45:40 by fabian.arellano)