Line 33: Line 33:
Range: ''' [ -1,700,000 , 1,500,000 ]'''  * '''Range:'''
  * '''LVDT:''' [ -1,700,000 , 1,500,000 ] µm
  * Stepper motor:
  * Temperature when measured:
 * Observations:
Line 36: Line 40:
Range: from -750 µm to 1000 µm in the LVDT and from 300,000 to 1,000,00 steps in the stepper motor ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4431|4431]]).  * '''Range:'''
  * '''LVDT:''' [ -750 , 1000 ] µm ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4431|4431]]).
  * '''Stepper motor:''' [ 300,000 , 1,000,00 ] steps ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4431|4431]]).
  * Temperature when measured:
 * Observations:

Describe KAGRA/Subgroups/VIS/OpsManual/FishingRods here.

This page describes the status of the fishing rods.

Beam splitter

Top filter

  • Range:

    • LVDT: [ -2500 , +4900 ] µm (7694).

    • Stepper motor: [ -1,400,000 , +1,400,000 ] steps (7694).

    • Temperature when measured:
  • Observations:

    • At 25 ºC it was possible to use the fishing rod to set the keystone at nominal position (8125).

    • at 24.5 ºC or colder it was not (8645, 11465).

Standard Filter

  • Range:

    • LVDT: [ -700 , +700 ] µm (3558).

    • Stepper motor: [ -870,000 to +835,000 ] steps (3558).

    • Temperature when measured:
  • Observations:

    • It's been at its lowest position since the temperature was 25 ºC (8125, 8645).

    • We set the keystone to 488 µm and couldn't move it further down (8125, 8645).

Bottom filter

  • Range:

    • LVDT: [ -1000 µm , +1800 ] µm (3280).

    • Stepper motor: [ -746,000 , +746,000 ] steps (3280).

    • Temperature when measured:
  • Observations: this fishing rod didn't seem to have any problems before but we haven't tried to use it at every temperature condition we've had.

SR2

Top filter

  • Range:

    • LVDT: [ -1,700,000 , 1,500,000 ] µm

    • Stepper motor:
    • Temperature when measured:
  • Observations:

Stardard filter

  • Range:

    • LVDT: [ -750 , 1000 ] µm (4431).

    • Stepper motor: [ 300,000 , 1,000,00 ] steps (4431).

    • Temperature when measured:
  • Observations:

Bottom filter

Range: from -500 µm to 600 µm in the LVDT and from -550,000 to -250,000 (4430).

8082