Differences between revisions 3 and 4
Revision 3 as of 2017-03-03 14:30:31
Size: 249
Editor: MarkBarton
Comment:
Revision 4 as of 2017-04-24 07:57:56
Size: 411
Editor: MarkBarton
Comment:
Deletions are marked like this. Additions are marked like this.
Line 5: Line 5:
 * Cling wrap in BF.
 * Temporary ballast mass in BF.
 * Galled pole in BF level of EQ stop.
 * Temporary geophone cables.
 * Remove cling wrap in BF and install vacuum-compatible heat shrink.
 * Swap out temporary ballast mass in BF.
 * If possible, fix galled pole in BF level of EQ stop.
 * Swap in final geophone cables.
 * Swap in new F0-SF maraging rod (with 8-mm heads) and new receptacles to match.

KAGRA VIS - Type B - BS Test Hang Issues

Things to remember/fix after BS Test Hang, before final hanging of BS.

  • Remove cling wrap in BF and install vacuum-compatible heat shrink.
  • Swap out temporary ballast mass in BF.
  • If possible, fix galled pole in BF level of EQ stop.
  • Swap in final geophone cables.
  • Swap in new F0-SF maraging rod (with 8-mm heads) and new receptacles to match.

KAGRA/Subgroups/VIS/TypeB/BSTestHangIssues (last edited 2017-06-19 10:12:23 by MarkBarton)