Differences between revisions 1 and 9 (spanning 8 versions)
Revision 1 as of 2020-05-11 10:55:32
Size: 923
Comment:
Revision 9 as of 2020-05-11 11:32:02
Size: 2140
Comment:
Deletions are marked like this. Additions are marked like this.
Line 6: Line 6:
Introductory paragraph.
Line 7: Line 9:
 * --(Brief description of the anatomy of the OSEMs.)--
 * Produce a nicer figure. (Fabian.)
 * --(Typical OSEM sensitivity measured when locking the target.)--
 * --(Typical measuring range according to all the units used in BS, SR2, SR3 and SRM.)--
 * Typical calibration value. (Fabian, klog 4189.)
 * Produce a nicer plot (Fabian).
 * Write the figure caption (Fabian).
 * Write a couple of sentences about the coil-magnet actuator and cite Mark’s document and Michimura-san’s paper. (Mark.)
Line 9: Line 20:
 * --(Brief description of the oplev.)--
 * --(Brief description of diagonalization procedure.)--
Line 12: Line 25:
 * Write the diameter of the beam determines the linear range of the QPD as a beam displacement sensor.
 * Point out that the oplev is expected to be limited by the seismic motion.
 * Say it is not easy to measure directly the oplev sensitivity but it is possible to set an upper limit to the optic rms displacement and velocities.
 * Write the diameter of the beam determines the linear range of the QPD as a beam displacement sensor. (Fabian.)
 * Point out that the oplev is expected to be limited by the seismic motion. (Fabian.)
 * Say it is not easy to measure directly the oplev sensitivity but it is possible to set an upper limit to the optic rms displacement and velocities. (Fabian.)
Line 16: Line 29:
=== Geophones === === Inertial sensors ===
 * --(Brief description of what a geophone is.)--
 * --(Brief explanation of the calculation of the noise determining the sensitivity.)--
 * Say that below the resonant frequency the noise goes as f^-{3.5} and explain the reason. (Fabian.)
 * --(Briefly say how they were calibrated against a calibrated seismometer.)--
 * --(Say the noise was measured using three channel correlation analysis.)--
 * --(Say we are in the process of finding out the reson of discrepancy betwwen the predicted and measured sensitivity.)--

Describe KAGRA/Subgroups/VIS/TypeB/PaperTODOlist here.

Introduction

The mechanical system

Sensors and actuators for control

Introductory paragraph.

OSEMs

  • Brief description of the anatomy of the OSEMs.

  • Produce a nicer figure. (Fabian.)
  • Typical OSEM sensitivity measured when locking the target.

  • Typical measuring range according to all the units used in BS, SR2, SR3 and SRM.

  • Typical calibration value. (Fabian, klog 4189.)
  • Produce a nicer plot (Fabian).
  • Write the figure caption (Fabian).
  • Write a couple of sentences about the coil-magnet actuator and cite Mark’s document and Michimura-san’s paper. (Mark.)

LVDTs

Optical lever

  • Brief description of the oplev.

  • Brief description of diagonalization procedure.

  • Where the displacement calibration comes from: relativeposition of components measured with ruler, dimensions given by the 3D-CAD, QPD displacement calibration and comparison with IP displacement.

  • Typical extent of coupling after diagonalization.

  • Typical measuring range.

  • Write the diameter of the beam determines the linear range of the QPD as a beam displacement sensor. (Fabian.)
  • Point out that the oplev is expected to be limited by the seismic motion. (Fabian.)
  • Say it is not easy to measure directly the oplev sensitivity but it is possible to set an upper limit to the optic rms displacement and velocities. (Fabian.)

Inertial sensors

  • Brief description of what a geophone is.

  • Brief explanation of the calculation of the noise determining the sensitivity.

  • Say that below the resonant frequency the noise goes as f^-{3.5} and explain the reason. (Fabian.)
  • Briefly say how they were calibrated against a calibrated seismometer.

  • Say the noise was measured using three channel correlation analysis.

  • Say we are in the process of finding out the reson of discrepancy betwwen the predicted and measured sensitivity.

Control and performance

What we have

What we aim for

KAGRA/Subgroups/VIS/TypeB/PaperTODOlist (last edited 2020-06-15 13:07:43 by fabian.arellano)