=== Reference ===
 .[[http://www.ligo.caltech.edu/docs/T/T970165-00.pdf|Old iLIGO, 1997]]
 .[[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=7881|aLIGO]]

----
=== PEM channel list ===

||Name||Laser||Center||IX||IY||EX||EY||MX||MY||control room||mine||outside(building)||Others(num., place)||
|| || || || || || || || || || || || ||
||Room temperature||1||1||1||1||1||1||1||1|| || ||1|| ||
||Optical table temperature||1||3(MC, REFL, AS)||1||1||1||1|| || || || || || ||
||Seismometer|| ||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis|| || ||1x3axis|| ||
||Tilt meter|| ||1||1||1||1||1|| || || || || || ||
||Humidity||1||1|| || ||1||1||1||1|| || || || ||
||Particle||1||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Microphone||1||3+5(each PD table)||1||1||1||1|| || || ||1|| || ||
||Air Pressure||1||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Magnetic field(3 axes)|| ||1||1||1||1||1||1?||1?|| ||1?|| || ||

 * IX:Room for ITMX, EX:Room for ETMX, MX:Room for middle of X arm, the same as Y

||Name||number||
|| || ||
||Low temperature monitor for suspensions||96(3ADCs) x 4sus=384||

 * 温度計の測定精度から16ビット以上を希望
 * 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要

Physical Environmental Monitoring Systm

Reference


PEM channel list

Name

Laser

Center

IX

IY

EX

EY

MX

MY

control room

mine

outside(building)

Others(num., place)

Room temperature

1

1

1

1

1

1

1

1

1

Optical table temperature

1

3(MC, REFL, AS)

1

1

1

1

Seismometer

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

Tilt meter

1

1

1

1

1

Humidity

1

1

1

1

1

1

Particle

1

1

1

1

1

1

1?

1?

1?

Microphone

1

3+5(each PD table)

1

1

1

1

1

Air Pressure

1

1

1

1

1

1

1?

1?

1?

Magnetic field(3 axes)

1

1

1

1

1

1?

1?

1?

  • IX:Room for ITMX, EX:Room for ETMX, MX:Room for middle of X arm, the same as Y

Name

number

Low temperature monitor for suspensions

96(3ADCs) x 4sus=384

  • 温度計の測定精度から16ビット以上を希望
  • 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要