Differences between revisions 31 and 32
Revision 31 as of 2017-04-04 14:02:29
Size: 3520
Comment:
Revision 32 as of 2017-04-04 14:03:16
Size: 3530
Comment:
Deletions are marked like this. Additions are marked like this.
Line 65: Line 65:
||0001 ||Leaking; was installed '''IXA'''||
||0002 ||Leaking; Was installed '''IXA'''||
||0001 ||Leaking; was once installed '''IXA'''||
||0002 ||Leaking; was once installed '''IXA'''||

Viewport windows for optical lever

Related subgroups: IOO, MIF, VAC, CRY, VIS...


Scope

  • Scope...

Oplev viewport windows

FY2013 version

VPZ100Q (ICF152)

Serial#

Status

0000

Leaking, but preserved in the tunnel

0001

Leaking, but preserved in the tunnel

0002

(Not yet checked.)

0003

(Not yet checked.)

0004

(Not yet checked.)

0005

Leaking, get back to the retailer (20170130)

0006

Leaking, get back to the retailer (20170130)

0007

Leaking, but preserved in the tunnel

0008

Leaking; was once installed IXC, returned in advanced, and checked at the company

0009

No leak; stocked at the side of IMC.

0010

No leak; stocked at the side of IMC.

0011

No leak; stocked at the side of IMC.

0012

No leak; stocked at the side of IMC.

0013

No leak; stocked at the side of IMC.

0014

(Not yet checked.)

0015

(Not yet checked.)

0016

Leaking, get back to the retailer (20170130)

0017

(Not yet checked.)

0018

Leaking, get back to the retailer (20170130)

0019

MCE, Leaking (20170303)

0020

MCF, Leaking (20170303)

0021

PR3, Not yet checked.

0022

MCE, No Leak detected (20170303)

0023

Preserved in a desiccator at PSL room, for some reasons, not yet checked.

0024

MCF, No Leak detected (20170303)

0025

Not yet checked; was once EYA, removed, but still stocked near the chamber.

0026

BS, not yet checked.

0027

BS, not yet checked.

0028

Leaking; was once installed EYC probably, returned in advanced, and checked at the company

0029

Not yet checked; was once EYA, removed, but still stocked near the chamber.

0030

Leaking, get back to the retailer (20170130)

0031

Reverse pressured.

0032

Leaking, get back to the retailer (20170130)

0033

Leaking, get back to the retailer (20170130)

0034

Leaking, get back to the retailer (20170130)

0035

Leaking; was once installed EYC probably, returned in advanced, and checked at the company

0036

Leaking, get back to the retailer (20170130)

0037

Leaking, get back to the retailer (20170130)

0038

Reverse pressured.

0039

(Not yet checked.)

0040

Leaking, get back to the retailer (20170130)

0041

IMM, not yet checked.

0042

Reverse pressured.

...Why 43 viewport windows? Probably some serial numbers are skipped when these were delivered... Actually 40 viewport windows were purchased.

VPZ38Q (ICF70)

Serial#

Status

0001

Leaking; was once installed IXA

0002

Leaking; was once installed IXA

0003

PR3, not yet checked.

0004

Leaking, but preserved in the tunnel

0005

Leaking, but preserved in the tunnel

0006

Leaking, but preserved in the tunnel

0007

Leaking, but preserved in the tunnel; was once installed EYA, and leak detected

0008

Leaking, but preserved in the tunnel; was once installed EYA, and leak detected

0009

Leaking, but preserved in the tunnel

0010

No leak probably; stocked at the side of IMC.

LCGT/subgroup/AOS/Viewport2017 (last edited 2022-10-06 13:35:26 by TomotadaAkutsu)