...Up

Simulation Tools

Name

Platform

Domain

Capabilities

Author

Web

Optickle

Matlab

Frequency Domain

Radiation Pressure, 01 mode

Matt Evans

Password protected

Finesse

C?

Frequency Domain

Higher order modes

Andreas Freise

http://www.rzg.mpg.de/~adf/

e2e

C++

Time Domain

Hiro Yamamoto

http://www.ligo.caltech.edu/~e2e/


Comparison of simulatio tools for LCGT

I am comparing several simulation tools with theoretical line using LCGT 2007 parameters. I used here FINESSE, Thomas, Oprickle. Except for FINESSE, all results matched pretty well within 0.1%-1% accuracy. FINESSE seems to have a bug of a factor by sqrt(2), but it can be compensated later if you know this information.

FPMI no loss case with LCGT parameters

FPMI_noloss.png

20090709_simall_FPMI_noloss.zip

PRFPMI no loss case with LCGT parameters

PRFPMI_noloss.png

20090709_simall_PRFPMI_noloss.zip