変電設備
配電盤
年間電力使用量試算 by Kuroda
|
Compressor for cryocooler 1 |
264 kW |
×24h×365×100% |
2,312,640 kWh |
|
Vacuum pump |
50 kW |
×24h×365× 5% |
21,900 kWh |
|
Vacuum tanks (center room) |
1 kW |
×24h×365×100% |
8,760 kWh |
|
Air conditioner w/ HEPA |
10 kW |
×12h×365×100% |
43,800 kWh |
|
Computer w/ air conditioner |
80 kW |
×24h×365×100% |
700,800 kWh |
|
Measurement instruments |
5 kW |
×12h×365×100% |
21,900 kWh |
|
Lighting equipment |
2 kW |
×24h×365× 20% |
3,504 kWh |
|
Cooling water pump |
1 kW |
×24h×365×100% |
8,760 kWh |
|
|
|
|
|
|
Total sum. |
413 kW |
|
3,122,064 kWh |
11 kW x24 (1)