'''Suspension Thermal noise''' | = Suspension Thermal noise for CLIO 081105 = |
Line 6: | Line 6: |
[[attachment:sus_thermal.txt]] | [[attachment:sus_thermal.txt]] |
Line 8: | Line 8: |
<<BR>>''' T = 300 K, fo = 0.7 Hz, Q = 1e+5 and by assuming of structure damping ''' |
|
Line 9: | Line 15: |
* '''Suspension thermal''' ''' fo = 0.7 Hz, Q = 1e+5 and by assuming of structure damping ''' ---- * Wire specification suspension wire: bolfur, 50 micron diameter, 400 mm length, 2 loops. mass: sapphire, 100 mm diameter, 60mm length, 1.8kg. |
''' * Wire specification . suspension wire: bolfur, 50 micron diameter, 400 mm length, 2 loops. . mass: sapphire, 100 mm diameter, 60mm thickness, 1.8kg. |
Line 20: | Line 20: |
* Q of Violin mode f1=699.05Hz, Q=1.0*10^5 f2=700.29Hz, Q=0.63*10^5 [[http://gw.icrr.u-tokyo.ac.jp:8888/clio_blog/2008/11/06/Graph_sens_081106_violin.pdf]] |
* Q of Violin mode . f1=699.05Hz, Q=1.0*10^5 . f2=700.29Hz, Q=0.63*10^5 [[http://gw.icrr.u-tokyo.ac.jp:8888/clio_blog/2008/11/06/Graph_sens_081106_violin.pdf]] ''' <<BR>> |
Line 25: | Line 27: |
* Extrapolation to Q of pendulum mode violin mode Q と pendulum Q の間には 1:2 or 1:4 の関係があるそうです。 |
* Extrapolation to pendulum mode Q ''violin mode Q と pendulum Q の間には 1:2 or 1:4 の関係があるそうです。'' (pending) |
Line 28: | Line 30: |
* Expectation of pendulum mode Q みよきさんによるボルファ単体の Q は 1000。 計算によるdissipation dilution factorは1.2*10^-4. これらを組み合わせると、期待されるQ=1*10^7. |
* Expectation of pendulum mode Q みよきさんによるボルファ単体の Q は 1000。 計算によるdissipation dilution factorは1.2*10^-4. これらを組み合わせると、期待されるQ=1*10^7. |
Suspension Thermal noise for CLIO 081105
T = 300 K, fo = 0.7 Hz, Q = 1e+5 and by assuming of structure damping
http://gw.icrr.u-tokyo.ac.jp:8888/clio_blog/2008/11/06/Graph_sens_081106_violin.pdf
- Extrapolation to pendulum mode Q
violin mode Q と pendulum Q の間には 1:2 or 1:4 の関係があるそうです。 (pending)
- Expectation of pendulum mode Q
- みよきさんによるボルファ単体の Q は 1000。 計算によるdissipation dilution factorは1.2*10^-4. これらを組み合わせると、期待されるQ=1*10^7.