Size: 1149
Comment:
|
Size: 1533
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
*[[http://gw.icrr.u-tokyo.ac.jp:8888/clio_blog/2008/11/081109rf-intensity-noise-080626.html|(2008/10/29)]] | ## page was renamed from noisebudget = CLIO常温 noise budget = [[target|{{attachment:CLIO_NoiseBudget_081219_1.png}}]] |
Line 4: | Line 7: |
[[target|{{attachment:n081029_4-thumb-555x407.jpg}}]] [[attachment:n081029_4.pdf]] |
(2008/12/19 by 我妻) |
Line 7: | Line 9: |
[[attachment:CLIO_NoiseBudget_081219.pdf]] | |
Line 8: | Line 11: |
[[attachment:CLIO_NoiseBudget_081219_C.pdf]] (5Hz ~ 3kHz) == noise source 解説 == |
|
Line 9: | Line 15: |
*[[CLIO/data/IntensityNoise|Intensity noise]] |
|
Line 10: | Line 19: |
*フィルタ雑音: 前出のフィルタの入力換算雑音vnを補正。error basedの感度、feedback basedの感度でフィルタ雑音の現れ方が変わる。ライン以外では今は問題なし。 | *[[CLIO/data/RFIntensityNoise|RF intensity noise]] *[[FeedbackFilter|フィルタ雑音]]: [[http://gw.icrr.u-tokyo.ac.jp:8888/clio_blog/2008/10/mass-filter-circuit-noise.html|前出]]のフィルタの入力換算雑音vnを補正。error basedの感度、feedback basedの感度でフィルタ雑音の現れ方が変わる。ライン以外では今は問題なし。 |
Line 13: | Line 25: |
---- *[[CLIO/req/noisebudgetLowPrediction|Noise budget:低温、予測]] |
CLIO常温 noise budget
CLIO_NoiseBudget_081219_C.pdf (5Hz ~ 3kHz)
noise source 解説
- 周波数雑音: inline armのerror信号を1e12[V/m], cavity pole 248Hzで換算してプロット。換算係数は100kHz付近のスペクトル形状が変位雑音と一致するように選んだ。8kHz以上で感度を制限。
- ショット雑音・検出系雑音: inline/perpendのPDのgdet, idetより復調出力に現れるショット雑音電圧・検出系雑音電圧を計算し、これを干渉計の応答および上記周波数雑音の応答で換算。500Hz~8kHzで感度を制限。(若干perp shot noiseは若干推定にズレがあるようだが)
フィルタ雑音: 前出のフィルタの入力換算雑音vnを補正。error basedの感度、feedback basedの感度でフィルタ雑音の現れ方が変わる。ライン以外では今は問題なし。
- feedback basedの場合: dx_filerr = vn / H (Hは干渉計の応答)
- error basedの場合: dx_filfb = vn G / H (Gはopenloop伝達関数)