Differences between revisions 25 and 51 (spanning 26 versions)
Revision 25 as of 2009-06-27 19:47:39
Size: 3300
Editor: whitehole
Comment:
Revision 51 as of 2009-07-19 13:30:51
Size: 5790
Editor: whitehole
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
||<#FFFF77>'''~+ [[CLIO/Meeting|/Meeting]] +~''' ||<#FFFF77>'''~+[[CLIO/Plans|/Plans]] +~''' ||<#FFFF77>'''~+[[CLIO/Tasks|/Tasks]] +~''' ||<#FFFF77>'''~+[[CLIO/Technicals|/Technicals]] +~''' ||<#FFFF77>'''~+[[CLIO/SiteInfo|/SiteInfo]] +~''' ||
||<#FFCCFF>'''~+ FindPage   +~'''||<#FFCCFF> '''~+ TitleIndex +~'''||<#FFCCFF> '''~+ WordIndex +~'''||<-2#FFCCFF>'''~+ HelpOnMoinWikiSyntax +~''' ||

Update: <<DateTime(2009-06-27T12:51:20+0900)>>
[[CLIO|{{attachment:CLIO/project/CLIOlogo.png|alt|width="150"}}]]
||<#FFFF77>'''~+ [[CLIO/Meeting|/Meeting]] +~''' ||<#FFFF77>'''~+[[CLIO/Tasks|/Current Tasks]] +~''' ||<#FFFF77>'''~+[[CLIO/NoiseBudgets|/Noise Budgets]] +~''' ||<#FFFF77>'''~+[[CLIO/Technicals|/Technicals]] +~''' ||<#FFFF77>'''~+[[CLIO/SiteInfo|/SiteInfo]] +~''' ||<#FFFF77>'''~+[[CLIO/Plans|/Past Plans]] +~'''||
||<#FFCCFF>'''~+ FindPage   +~'''||<#FFCCFF> '''~+ TitleIndex +~'''||<#FFCCFF> '''~+ WordIndex +~'''||<-2#FFCCFF>'''~+ HelpOnMoinWikiSyntax +~''' || ||
Line 17: Line 16:
=== Measured Q values ===
|| Temperature || Torsion Mode || Pendulum Mode ||
|| 300 K || 20 || 470 ||
|| 77 K || --- || 5900 ||
|| 4 K || --- || ||

=== 2009-07-16 (D. Tatsumi) ===
<<Anchor(090716)>>
 . ''Lost the sensor signal, when we pour liquid He for cryostat cooling''.
 . ''Therefore, we gave up to make an experiment at 4K today''.

 . Al Q measurement at 77 K
 . Pendulum mode Q = 5900
 . [[attachment:alq_t300_090716_1.pdf]] (In He gas: 200 Pa)
 . [[attachment:alq_t300_090716_2.pdf]] (In vacuum: 2.5e-4 Pa)
 . {{attachment:alq_t300_090716_1.png|alt|width="450"}}

=== 2009-07-15 (D. Tatsumi) ===
<<Anchor(090715)>>
 . Al Q measurement at 300 K
 . Pendulum mode Q = 470
 . [[attachment:alq_t300_090715.pdf]]
 . {{attachment:alq_t300_090715.png|alt|width="450"}}

=== 2009-07-14 (D. Tatsumi) ===
<<Anchor(090714)>>
 . Setup for Al Q measurements
 [[attachment:P1080559.JPG]]
 [[attachment:P1080560.JPG]]

 . At 300K in air
 . Torsion mode Q = 20 / Torsion Mode
 [[attachment:alq_t300_090714.pdf]]
 [[attachment:alq_spec_090714.pdf]]
 {{attachment:alq_t300_090714.png|alt|width="450"}}

=== 2009-07-09 (T. Suzuki) ===
<<Anchor(090709)>>
 .(1)Al線Q値測定
 . 来週(7/13〜7/17)辰巳さんがKEKに来て実験するため準備中。

 . (2)Al線のRRR
 . 新冨先生に測っていただいた。3本同時測定。Nilacoから購入の99.999%, d= 0.5mm wire。

 . Sample 1 : 常温での振り子Q測定に使った線。一度450gfくらいの張力をかけている。
 . Sample 2 : Nilacoから購入のまま。
 . Sample 3 : Nilacoから購入のまま。

 . 抵抗測定:4端子法、電流=100mA
 . 温度測定:G10基板に付けたSi diode. Lakeshore 218 Controllerで温度直読。
 . 温度制御:均音化のため試料を取り付けたG10基板全体をAl foilでくるむ。
 . 室温は空中放置。4Kは液体ヘリウム中に浸す。

 . 測定結果
 . Sample 1 : R(299.6K)= 13.859mOhm , R(4.068K)= 5.7microOhm -> RRR= 2400
 . Sample 2 : R(299.5K)= 14.01mOhm , R(4.068K)= 6.2microOhm -> RRR=2300
 . Sample 3 : R(299.5K)= 13.95mOhm , R(4.068K)= 6.5microOhm -> RRR=2100

 .(3)温度計配線の温度変化による変形の試験
 . まだ試していません。
Line 18: Line 78:
<<Anchor(090625)>>
Line 30: Line 91:
<<Anchor(090313)>>
Line 43: Line 105:


 .
Line 47: Line 106:


 .
Line 51: Line 107:


 .
Line 55: Line 108:


 .
Line 59: Line 109:
 || Be Cu  || 0.09mm  || || 860MPa ||
 || Super Invar  || 0.1mm  || || 1.2GPa ||
 ||ヤニ入りハンダ  || 0.8mm  || || 24MPa ||
|| Be Cu  || 0.09mm  || || 860MPa ||
|| Super Invar  || 0.1mm  || || 1.2GPa ||
||ヤニ入りハンダ  || 0.8mm  || || 24MPa ||

alt

/Meeting

/Current Tasks

/Noise Budgets

/Technicals

/SiteInfo

/Past Plans

FindPage   

TitleIndex

WordIndex

HelpOnMoinWikiSyntax

方針 (2009/01/08 by 内山)

  • ニラコ、AL-011385, Φ0.50mm, 99.999%, 3500yen/1m
    を使う。 Q値測定に用いる同一ロットのものを、最終段懸架用ワイヤーに使うこととする。

Requirements

  • temperature at suspension point: 10K.
  • suspension wire: Aluminum, Φ0.5mm*400mm, 2 loops.
  • Q of wire: 104 --> minimal success 103

  • Q of pendulum: 1.2*106 --> 1.25*105

Measured Q values

Temperature

Torsion Mode

Pendulum Mode

300 K

20

470

77 K

---

5900

4 K

---

2009-07-16 (D. Tatsumi)

  • Lost the sensor signal, when we pour liquid He for cryostat cooling.

  • Therefore, we gave up to make an experiment at 4K today.

  • Al Q measurement at 77 K
  • Pendulum mode Q = 5900
  • alq_t300_090716_1.pdf (In He gas: 200 Pa)

  • alq_t300_090716_2.pdf (In vacuum: 2.5e-4 Pa)

2009-07-15 (D. Tatsumi)

2009-07-14 (D. Tatsumi)

2009-07-09 (T. Suzuki)

  • (1)Al線Q値測定
  • 来週(7/13〜7/17)辰巳さんがKEKに来て実験するため準備中。
  • (2)Al線のRRR
  • 新冨先生に測っていただいた。3本同時測定。Nilacoから購入の99.999%, d= 0.5mm wire。
  • Sample 1 : 常温での振り子Q測定に使った線。一度450gfくらいの張力をかけている。
  • Sample 2 : Nilacoから購入のまま。
  • Sample 3 : Nilacoから購入のまま。
  • 抵抗測定:4端子法、電流=100mA
  • 温度測定:G10基板に付けたSi diode. Lakeshore 218 Controllerで温度直読。
  • 温度制御:均音化のため試料を取り付けたG10基板全体をAl foilでくるむ。
  • 室温は空中放置。4Kは液体ヘリウム中に浸す。
  • 測定結果
  • Sample 1 : R(299.6K)= 13.859mOhm , R(4.068K)= 5.7microOhm -> RRR= 2400

  • Sample 2 : R(299.5K)= 14.01mOhm , R(4.068K)= 6.2microOhm -> RRR=2300

  • Sample 3 : R(299.5K)= 13.95mOhm , R(4.068K)= 6.5microOhm -> RRR=2100

  • (3)温度計配線の温度変化による変形の試験
  • まだ試していません。

2009-06-25 (T. Suzuki)

  • * 300K Al dia.=0.5mm 振り子 Q=400〜450、 捻れ振動 Q=40。
  • 錘 m=49g 、 L〜29cm wire 下端と錘および wire 上端の固定はピンバイスを使用。
  • 同じ仕掛けでサファイア dia.=0.25mm に代えると、振り子でQ=1200, 捻れでQ=450 なので、Alの値は一応300KでのQ値とみて良いだろう。

    写真はAlで吊った仕掛けの外観。 P1080411s.jpg

  • * 温度を変えての測定は、7/13の週に辰巳氏がKEKに来る予定なので準備を進める。

2009-03-13 (T. Suzuki)

  • ・CLIO Al wire (5N, dia.=0.5 mm, 20m) 届いた
  • ・Handy Force Gauge (ALGOL HF-50)で破断応力測定。
    • 端は直径6mmのSUS棒に巻きつけた摩擦とビスでの押さえを使って固定。
    • 破断は試験ワイアーの直線部で起こっているので、端をつぶした影響は無いと観てよいだろう。
    • 破断時の最大張力を記録して、ワイアー断面積を使って応力に換算。
    • ワイアーが伸びて 直径が小さくなる分は無視している。
    • Nilaco 5N Al wire dia.=0.5mmは2回測定して、16.5N, 16.4Nだった。 破断応力にして42MPa。
    • . ついでに、他のワイアー(あるいはファイバー)も測ったものを書いておくと以下のとおり。
    • 細いワイアーの直径測定はMitsutoyoのディジタルノギスを使っているが、
    • 表示は 0.01mmの桁までなので、この細さのワイアーは誤差が大きいと思われる。

材質

Diameter (mm)

破断力 (N)

破断応力

Nilaco 5N Al

0.5

16.5N, 16.4N

42MPa

ダイニーマ(高張力ポリエチレン) 

0.01

 

8.5GPa

カーボンワイアー 

0.01mm 

5.0GPa

W 

0.03mm 

3.2GPa

Be Cu 

0.09mm 

860MPa

Super Invar 

0.1mm 

1.2GPa

ヤニ入りハンダ 

0.8mm 

24MPa

  • φ100mm d60mm のサファイヤ鏡は 1.8kg --> 450g重/wire = 4.5N/wire よって、破断応力の 1/4 程度の応力が働いている。

  • ・Q測定は調整中。
    • 捻れ振動を使う予定。 トランスデューサーは静電容量型。