Differences between revisions 40 and 67 (spanning 27 versions)
Revision 40 as of 2018-12-26 10:47:51
Size: 5757
Comment:
Revision 67 as of 2019-01-28 14:26:11
Size: 6087
Comment:
Deletions are marked like this. Additions are marked like this.
Line 8: Line 8:
||X end 2F || 52A01114 || 192.168.11.26 ||X end 2F || exvbooth, exv2, exv3 ||
Line 23: Line 24:
||(reserved) ||icv || ||Front 2F || ||Relay1 ||icv || '''serial check''' ||Front 2F ||
Line 32: Line 33:
||Name ||Serial # ||Location ||koki # || ||Name ||Serial # ||Location ||koki # || Comment ||
Line 37: Line 38:
||ioo1 || ||ioo1 rack || || '''new1''' ||
||ioo2 || ||ioo2 rack || || empty ||
||omc0 || ||omc0 rack || || '''new2''' ||
||pr3 || ||pr3 rack || || '''new3''' ||
||bs || ||bs rack || || '''new4''' ||
||sr2 || ||sr2 rack || || '''new5''' ||
||srm || ||srm rack || || '''new6''' ||
||lsc0 || ||lsc0 rack|| || '''new7''' ||
||asc0 || ||asc0 rack || || '''new8''' ||
||asc1 || ||asc1 rack || || empty ||
||als0 || ||als0 rack || || '''new9''' ||
||als1 || ||als1 rack || || '''new10''' ||
||ix0 || ||ix0 rack || || -{{'''new11'''}}- ||
||iy0 || ||iy0 rack || || '''new12''' ||
||ioo1 ||52C61A23 ||ioo1 rack ||25||
||ioo2 || ||ioo2 rack || rack 未設置 ||
||omc0 ||52C619F0 ||omc0 rack ||28 ||
||pr3 ||52C61A12 ||pr3 rack ||34 ||
||bs ||52C61A28 ||bs rack ||29 ||
||sr2 ||52C61A1A ||sr2 rack ||31 ||
||srm ||52C61A19 ||srm rack ||30 ||
||lsc0 ||52C61A16 ||lsc0 rack||32 ||
||asc0 ||52C61A2A ||asc0 rack ||33 ||
||asc1 || ||asc1 rack || rack 未設置||
||als0 ||52C614DA||als0 rack ||26||
||als1 ||52C61A13 ||als1 rack ||27 ||
||ix0 || ||ix0 rack || インストール必要か要議論||
||iy0 || ||iy0 rack || インストール必要か要議論||
||sr3 || || sr3 rack ||!!!||
Line 59: Line 61:
||crydr ||52C6122A ||低温機械室 tent1 ||12 ||
||crydr2 ||52C6122E ||低温機械室 tent2 ||13 ||
||crydr||52C6122A ||低温機械室 tent1 ||12 ||
||--(crydr2)-- ||--(52C6122E)-- ||--(低温機械室 tent2)-- ||--(13)-- ||
Line 64: Line 66:
||iya ||52C61505 ||Around IYA duct ||11 || ||iya ||52C61505 ||Around IYA duct, mooved (2019/1/9) ||11 ||
||bsair||??? || Airduct at center area ||35 ||
Line 90: Line 92:
||exair ||??? ||Airduct at Xend ||
Line 91: Line 94:
||tmsx || || tmsx rack || '''new13''' ||
||tmsxf || || tmsx clean booth ||  '''new14''' ||
||tmsx || || tmsx rack ||
||tmsxf || || tmsx clean booth ||
Line 96: Line 99:
||Name ||Serial # ||Location ||
||exv1 || ||EX1 (2F) rack || '''new15''' ||
||exv2 ||
||EX2 (2F) rack || '''new16''' ||
||exv3 || ||EX3 (2F) rack || '''new17''' ||
||exvbooth || ||EX 2F clean booth || '''new18''' ||
||Name ||Serial # ||Location ||Koki# ||
||exv1 || ||EX1 (2F) rack || ||
||exv2 ||
52C61A1B ||EX2 (2F) rack ||2 ||
||exv3 ||52C61A1C ||EX3 (2F) rack ||3 ||
||exvbooth ||52CA61A26 ||EX 2F clean booth ||1 ||
Line 114: Line 117:
||tmsy || || tmsy rack ||  '''new19''' ||
||tmsyf || || tmsy clean booth ||  '''new20''' ||
||eyair ||??? ||Airduct at Yend || 5 ||
||tmsy || || tmsy rack || ||
||tmsyf || || tmsy clean booth || ||
Line 122: Line 126:
||exv3 || ||EX3 (2F) rack || '''new21''' || ||exv3 || ||EX3 (2F) rack ||
Line 133: Line 137:
||icv || ||中央2Fcenter || || '''new22''' ||
||IXVbooth || || || || '''new23''' ||
||IYVbooth || || || || '''new24''' ||
||icv || ||中央2Fcenter || ||
||IXVbooth || || || ||
||IYVbooth || || || ||
Line 143: Line 147:
Last update: Jam.28th, 2019 by Yokozawa. 子機10個を追加購入
Jan. 11th, 2019 by Yokozawa. 新ラック等に子機インストール、親機の追加


Line 148: Line 157:
||バッテリ付き子機 ||18 || ||バッテリ付き子機 ||10 ||
Line 150: Line 159:
||バッテリ ||40ぐらい || ||バッテリ ||32 ||
Line 157: Line 166:
||old exc ||52C614Da ||Back in Storage ||N/A || ||old exc ||52C614DA ||Back in Storage ||N/A ||

Item List

親機リスト Base station list

Name

Serial #

IP address

Location

Connected to

Center

52A0101E

10.68.140.1

Center digital room in Mine

Relay1, dr, outdr

X end

52A0112B

192.168.10.4 192.168.10.2 (local)
10.68.10.209

X end station, on a AED rack

1F EXC, 2F EXC, Racks

X end 2F

52A01114

192.168.11.26

X end 2F

exvbooth, exv2, exv3

Y end

52A0107C

192.168.10.5 (local)
10.68.10.229

Top of EY1 rack

1F EYC, 2F EYC, Racks

Mozumi Station

52A002A0

10.68.11.10
192.168.11.2 (local)

Control Room

SVR

Yend 2F

52A01115

192.168.11.16 (local)
10.68.10.230

Y end 2F area (EYV)

X500m (PX)

52A01117

10.68.140.2 192.168.11.4 (local)
10.68.10.189

GIF Area

Front 2F(New One)

52A01326

10.68.140.2

Front 2F

中継器リスト Relay station list

Name

Connected to

Serial #

Location

Relay1

Relay2, center

529A13E8

Location

Relay2

Relay3, imc, ioo, mcrack, pr2, prm, psl

529A1401

Location

Relay3

ixa

529A1853

By IXA clean booth / Cryomachine room door

Relay4

crydr

529A1855

Location

Relay5

iya

529A186A

Location

Relay1

icv

serial check

Front 2F

子機リスト Data logger list

  • channelは、K1:PEM-(TEMPERATURE/HUMIDITY)_XXX
  • Rack listは、Dec.3, 2018 ver(yamat)

Center Racks

Name

Serial #

Location

koki #

Comment

mc rack

52C61128

MC Rack

1

ioo

52C610D7

IOO Rack

6

pr2

52C61227

PR2 Rack

7

prm

52C61226

PRM Rack

8

ioo1

52C61A23

ioo1 rack

25

ioo2

ioo2 rack

rack 未設置

omc0

52C619F0

omc0 rack

28

pr3

52C61A12

pr3 rack

34

bs

52C61A28

bs rack

29

sr2

52C61A1A

sr2 rack

31

srm

52C61A19

srm rack

30

lsc0

52C61A16

lsc0 rack

32

asc0

52C61A2A

asc0 rack

33

asc1

asc1 rack

rack 未設置

als0

52C614DA

als0 rack

26

als1

52C61A13

als1 rack

27

ix0

ix0 rack

インストール必要か要議論

iy0

iy0 rack

インストール必要か要議論

sr3

sr3 rack

!!!

Center Fields

Name

Serial #

Location

koki #

out dr

52C61234

Outside of the mine digital room

2

dr

52C61234

Inside of the mine digital room

3

center

52C61128

On the wall close to the BS booth

4

imc

52C610DB

On the big white shelf close to the IMC and PSL

5

crydr

52C6122A

低温機械室 tent1

12

crydr2

52C6122E

低温機械室 tent2

13

psl

52C61518

Entrance of the PSL enclosure

9

psl2

52C61A2C

In front of PSL's airconditioner

19

ixa

52C61506

Around IXA duct

10

iya

52C61505

Around IYA duct, mooved (2019/1/9)

11

bsair

???

Airduct at center area

35

Center Booth

Name

Serial #

Location

koki #

pr booth

52C6199F

PR booth

 15

mcf booth

52C619A0

mcf booth

 16

bs booth

52C61A27

bs booth

 17

pslbooth

52C61A29

PSL clean area

18

PR2booth

52C61A20

20

PR3booth

52C61A18

PR3 booth

21

SR2booth

52C61A1F

22

SR3booth

52C61A04

5/24 '18

14

IXAbooth

52C61A21

23

IYAbooth

52C614C9

24

X end 1F

Name

Serial #

Location

ex1

Xend, DGS rack

exc1f

52C6199E

X end, EXC clean booth 1F

exc2f

52C614D9

X end, EXC clean booth 2F

exa

52C61A03

X end, EXA.

exair

???

Airduct at Xend

old exa

Sealed in the EXA metal rack and not accessible. Not used or not registered to the base station

tmsx

tmsx rack

tmsxf

tmsx clean booth

X end 2F

Name

Serial #

Location

Koki#

exv1

EX1 (2F) rack

exv2

52C61A1B

EX2 (2F) rack

2

exv3

52C61A1C

EX3 (2F) rack

3

exvbooth

52CA61A26

EX 2F clean booth

1

X Mid (500m)

Name

Serial #

Location

px1

52C61A00

Special DGS rack (not online yet)

field_px

52C61A22

In Field (not online yet)

Y end

Name

Serial #

Location

Koki #

ey1

52C614D8

EY0 rack

1

eyc1f

52C614DC

Yend clean booth 1F

2

eyc2f

52C61A1E

Yend clean booth 2F

3

eya

52C61A01

iKAGRA EYA booth

4

eyair

???

Airduct at Yend

5

tmsy

tmsy rack

tmsyf

tmsy clean booth

Y end 2F

Name

Serial #

Location

eyv1

52C61A2B

EY1 (2F) rack

eyv2

52C61A17

EY2 (2F) rack

exv3

EX3 (2F) rack

eyvbooth

52C61A02

EY 2F clean booth

Front 2F

Name

Serial #

Location

koki #

icv1

52C614CB

Front(2F) rack

1

ixv1

52C614DB

IX(2F) 1st rack

2

ixv2

52C614CC

IX(2F) 2nd rack

3

iyv1

52C614CA

IY(2F) 1st rack

4

iyv2

52C614CD

IY(2F) 2st rack

5

icv

中央2Fcenter

IXVbooth

IYVbooth

Mozumi

Name

Serial #

Location

koki #

SVR

52C61229

Mozumi server room rear

1

在庫リスト

Last update: Jam.28th, 2019 by Yokozawa. 子機10個を追加購入 Jan. 11th, 2019 by Yokozawa. 新ラック等に子機インストール、親機の追加

在庫は低音機械室のテント(手前側)に保管。

Name

Number of stock

親機

1

中継機

4

中継機電源

9

バッテリ付き子機

10

probeのみ

7

バッテリ

32

Y end

Name

Serial #

Location

Koki #

old exc

52C614DA

Back in Storage

N/A