5757
Comment:
|
6310
|
Deletions are marked like this. | Additions are marked like this. |
Line 8: | Line 8: |
||X end 2F || 52A01114 || 192.168.11.26 ||X end 2F || exvbooth, exv2, exv3 || | |
Line 22: | Line 23: |
||Relay6 ||Relay1故障に伴い、Relay1と同じ場所に追加 || 529A1859||実験室窓|| | |
Line 23: | Line 25: |
||(reserved) ||icv || ||Front 2F || | ||Relay1 ||icv || 529A185B ||Front 2F || |
Line 32: | Line 34: |
||Name ||Serial # ||Location ||koki # || | ||Name ||Serial # ||Location ||koki # || Comment || |
Line 37: | Line 39: |
||ioo1 || ||ioo1 rack || || '''new1''' || ||ioo2 || ||ioo2 rack || || empty || ||omc0 || ||omc0 rack || || '''new2''' || ||pr3 || ||pr3 rack || || '''new3''' || ||bs || ||bs rack || || '''new4''' || ||sr2 || ||sr2 rack || || '''new5''' || ||srm || ||srm rack || || '''new6''' || ||lsc0 || ||lsc0 rack|| || '''new7''' || ||asc0 || ||asc0 rack || || '''new8''' || ||asc1 || ||asc1 rack || || empty || ||als0 || ||als0 rack || || '''new9''' || ||als1 || ||als1 rack || || '''new10''' || ||ix0 || ||ix0 rack || || --('''new11''')-- || ||iy0 || ||iy0 rack || || '''new12''' || |
||ioo1 ||52C61A23 ||ioo1 rack ||25|| ||ioo2 || ||ioo2 rack || rack 未設置 || ||omc0 ||52C619F0 ||omc0 rack ||28 || ||pr3 ||52C61A12 ||pr3 rack ||34 || ||bs ||52C61A28 ||bs rack ||29 || ||sr2 ||52C61A1A ||sr2 rack ||31 || ||srm ||52C61A19 ||srm rack ||30 || ||lsc0 ||52C61A16 ||lsc0 rack||32 || ||asc0 ||52C61A2A ||asc0 rack ||33 || ||asc1 || ||asc1 rack || rack 未設置|| ||als0 ||52C614DA||als0 rack ||26|| ||als1 ||52C61A13 ||als1 rack ||27 || ||ix0 || ||ix0 rack || インストール必要か要議論|| ||iy0 || ||iy0 rack || インストール必要か要議論|| ||sr3 ||52C63064 || sr3 rack ||36|| |
Line 56: | Line 59: |
||dr ||52C61234 ||Inside of the mine digital room ||3 || | ||dr ||52C61233 ||Inside of the mine digital room ||3 || |
Line 59: | Line 62: |
||crydr ||52C6122A ||低温機械室 tent1 ||12 || ||crydr2 ||52C6122E ||低温機械室 tent2 ||13 || |
||crydr||52C6122A ||低温機械室 tent1 ||12 || ||crydr2 ||52C6122E ||低温機械室 tent2 ||13 || 元に戻す!!!! || |
Line 64: | Line 67: |
||iya ||52C61505 ||Around IYA duct ||11 || | ||iya ||52C61505 ||Around IYA duct, mooved (2019/1/9) ||11 || ||bsair||52C63066 || Airduct at center area ||35|| |
Line 82: | Line 85: |
Line 85: | Line 86: |
||Name ||Serial # ||Location || ||ex1 || ||Xend, DGS rack || ||exc1f ||52C6199E ||X end, EXC clean booth 1F || ||exc2f ||52C614D9 ||X end, EXC clean booth 2F || ||exa ||52C61A03 ||X end, EXA. || |
||Name ||Serial # ||Location || Koki#|| ||ex1 || ||Xend, DGS rack || 2 || ||exc1f ||52C6199E ||X end, EXC clean booth 1F || 1 || ||exc2f ||52C614D9 ||X end, EXC clean booth 2F || 3 || ||exa ||52C61A03 ||X end, EXA. || 4 || ||exair ||??? ||Airduct at Xend || 5 || |
Line 91: | Line 93: |
||tmsx || || tmsx rack || '''new13''' || ||tmsxf || || tmsx clean booth || '''new14''' || |
||tmsx || || tmsx rack || '''New7'''|| ||tmsxf || || tmsx clean booth || '''New5'''|| |
Line 96: | Line 98: |
||Name ||Serial # ||Location || ||exv1 || ||EX1 (2F) rack || '''new15''' || ||exv2 || ||EX2 (2F) rack || '''new16''' || ||exv3 || ||EX3 (2F) rack || '''new17''' || ||exvbooth || ||EX 2F clean booth || '''new18''' || |
||Name ||Serial # ||Location ||Koki# || ||exv1 || ||EX1 (2F) rack || '''New3'''|| ||exv2 ||52C61A1B ||EX2 (2F) rack ||2 || ||exv3 ||52C61A1C ||EX3 (2F) rack ||3 || ||exvbooth ||52CA61A26 ||EX 2F clean booth ||1 || |
Line 114: | Line 116: |
||tmsy || || tmsy rack || '''new19''' || ||tmsyf || || tmsy clean booth || '''new20''' || |
||eyair ||52C61A24 ||Airduct at Yend || 5 || ||tmsy || || tmsy rack || '''New8'''|| ||tmsyf || || tmsy clean booth || '''New6'''|| |
Line 119: | Line 122: |
||Name ||Serial # ||Location || ||eyv1 ||52C61A2B ||EY1 (2F) rack || ||eyv2 ||52C61A17 ||EY2 (2F) rack || ||exv3 || ||EX3 (2F) rack || '''new21''' || ||eyvbooth ||52C61A02 ||EY 2F clean booth || |
||Name ||Serial # ||Location ||Koki#|| ||eyv1 ||52C61A2B ||EY1 (2F) rack ||1 || ||eyv2 ||52C61A17 ||EY2 (2F) rack ||2 || ||exv3 ||52C61A02 ||EX3 (2F) rack || 3|| ||eyvbooth || 52C61A1D ||EY 2F clean booth ||4 || |
Line 133: | Line 136: |
||icv || ||中央2Fcenter || || '''new22''' || ||IXVbooth || || || || '''new23''' || ||IYVbooth || || || || '''new24''' || |
||IXVbooth ||52C6199D ||IX(2F) booth ||6 || ||IYVbooth ||52C6199C ||IY(2F) booth || 7|| |
Line 143: | Line 145: |
Last update: Jam.28th, 2019 by Yokozawa. 子機10個を追加購入 Jan. 11th, 2019 by Yokozawa. 新ラック等に子機インストール、親機の追加 |
|
Line 148: | Line 155: |
||バッテリ付き子機 ||18 || | ||バッテリ付き子機 ||10 || |
Line 150: | Line 157: |
||バッテリ ||40ぐらい || | ||バッテリ ||32 || |
Line 157: | Line 164: |
||old exc ||52C614Da ||Back in Storage ||N/A || | ||old exc ||52C614DA ||Back in Storage ||N/A || |
Item List
親機リスト Base station list
Name |
Serial # |
IP address |
Location |
Connected to |
Center |
52A0101E |
10.68.140.1 |
Center digital room in Mine |
Relay1, dr, outdr |
X end |
52A0112B |
192.168.10.4 192.168.10.2 (local) |
X end station, on a AED rack |
1F EXC, 2F EXC, Racks |
X end 2F |
52A01114 |
192.168.11.26 |
X end 2F |
exvbooth, exv2, exv3 |
Y end |
52A0107C |
192.168.10.5 (local) |
Top of EY1 rack |
1F EYC, 2F EYC, Racks |
Mozumi Station |
52A002A0 |
10.68.11.10 |
Control Room |
SVR |
Yend 2F |
52A01115 |
192.168.11.16 (local) |
Y end 2F area (EYV) |
|
X500m (PX) |
52A01117 |
10.68.140.2 192.168.11.4 (local) |
GIF Area |
|
Front 2F(New One) |
52A01326 |
10.68.140.2 |
Front 2F |
|
中継器リスト Relay station list
Name |
Connected to |
Serial # |
Location |
Relay1 |
Relay2, center |
529A13E8 |
Location |
Relay2 |
Relay3, imc, ioo, mcrack, pr2, prm, psl |
529A1401 |
Location |
Relay3 |
ixa |
529A1853 |
By IXA clean booth / Cryomachine room door |
Relay4 |
crydr |
529A1855 |
Location |
Relay5 |
iya |
529A186A |
Location |
Relay6 |
Relay1故障に伴い、Relay1と同じ場所に追加 |
529A1859 |
実験室窓 |
|
|
|
|
Relay1 |
icv |
529A185B |
Front 2F |
子機リスト Data logger list
- channelは、K1:PEM-(TEMPERATURE/HUMIDITY)_XXX
Rack listは、Dec.3, 2018 ver(yamat)
Center Racks
Name |
Serial # |
Location |
koki # |
Comment |
mc rack |
52C61128 |
MC Rack |
1 |
|
ioo |
52C610D7 |
IOO Rack |
6 |
|
pr2 |
52C61227 |
PR2 Rack |
7 |
|
prm |
52C61226 |
PRM Rack |
8 |
|
ioo1 |
52C61A23 |
ioo1 rack |
25 |
|
ioo2 |
|
ioo2 rack |
rack 未設置 |
|
omc0 |
52C619F0 |
omc0 rack |
28 |
|
pr3 |
52C61A12 |
pr3 rack |
34 |
|
bs |
52C61A28 |
bs rack |
29 |
|
sr2 |
52C61A1A |
sr2 rack |
31 |
|
srm |
52C61A19 |
srm rack |
30 |
|
lsc0 |
52C61A16 |
lsc0 rack |
32 |
|
asc0 |
52C61A2A |
asc0 rack |
33 |
|
asc1 |
|
asc1 rack |
rack 未設置 |
|
als0 |
52C614DA |
als0 rack |
26 |
|
als1 |
52C61A13 |
als1 rack |
27 |
|
ix0 |
|
ix0 rack |
インストール必要か要議論 |
|
iy0 |
|
iy0 rack |
インストール必要か要議論 |
|
sr3 |
52C63064 |
sr3 rack |
36 |
Center Fields
Name |
Serial # |
Location |
koki # |
|
out dr |
52C61234 |
Outside of the mine digital room |
2 |
|
dr |
52C61233 |
Inside of the mine digital room |
3 |
|
center |
52C61128 |
On the wall close to the BS booth |
4 |
|
imc |
52C610DB |
On the big white shelf close to the IMC and PSL |
5 |
|
crydr |
52C6122A |
低温機械室 tent1 |
12 |
|
crydr2 |
52C6122E |
低温機械室 tent2 |
13 |
元に戻す!!!! |
psl |
52C61518 |
Entrance of the PSL enclosure |
9 |
|
psl2 |
52C61A2C |
In front of PSL's airconditioner |
19 |
|
ixa |
52C61506 |
Around IXA duct |
10 |
|
iya |
52C61505 |
Around IYA duct, mooved (2019/1/9) |
11 |
|
bsair |
52C63066 |
Airduct at center area |
35 |
Center Booth
Name |
Serial # |
Location |
koki # |
pr booth |
52C6199F |
PR booth |
15 |
mcf booth |
52C619A0 |
mcf booth |
16 |
bs booth |
52C61A27 |
bs booth |
17 |
pslbooth |
52C61A29 |
PSL clean area |
18 |
PR2booth |
52C61A20 |
|
20 |
PR3booth |
52C61A18 |
PR3 booth |
21 |
SR2booth |
52C61A1F |
|
22 |
SR3booth |
52C61A04 |
5/24 '18 |
14 |
IXAbooth |
52C61A21 |
|
23 |
IYAbooth |
52C614C9 |
|
24 |
X end 1F
Name |
Serial # |
Location |
Koki# |
ex1 |
|
Xend, DGS rack |
2 |
exc1f |
52C6199E |
X end, EXC clean booth 1F |
1 |
exc2f |
52C614D9 |
X end, EXC clean booth 2F |
3 |
exa |
52C61A03 |
X end, EXA. |
4 |
exair |
??? |
Airduct at Xend |
5 |
old exa |
|
Sealed in the EXA metal rack and not accessible. Not used or not registered to the base station |
|
tmsx |
|
tmsx rack |
New7 |
tmsxf |
|
tmsx clean booth |
New5 |
X end 2F
Name |
Serial # |
Location |
Koki# |
exv1 |
|
EX1 (2F) rack |
New3 |
exv2 |
52C61A1B |
EX2 (2F) rack |
2 |
exv3 |
52C61A1C |
EX3 (2F) rack |
3 |
exvbooth |
52CA61A26 |
EX 2F clean booth |
1 |
X Mid (500m)
Name |
Serial # |
Location |
px1 |
52C61A00 |
Special DGS rack (not online yet) |
field_px |
52C61A22 |
In Field (not online yet) |
Y end
Name |
Serial # |
Location |
Koki # |
ey1 |
52C614D8 |
EY0 rack |
1 |
eyc1f |
52C614DC |
Yend clean booth 1F |
2 |
eyc2f |
52C61A1E |
Yend clean booth 2F |
3 |
eya |
52C61A01 |
iKAGRA EYA booth |
4 |
eyair |
52C61A24 |
Airduct at Yend |
5 |
tmsy |
|
tmsy rack |
New8 |
tmsyf |
|
tmsy clean booth |
New6 |
Y end 2F
Name |
Serial # |
Location |
Koki# |
eyv1 |
52C61A2B |
EY1 (2F) rack |
1 |
eyv2 |
52C61A17 |
EY2 (2F) rack |
2 |
exv3 |
52C61A02 |
EX3 (2F) rack |
3 |
eyvbooth |
52C61A1D |
EY 2F clean booth |
4 |
Front 2F
Name |
Serial # |
Location |
koki # |
icv1 |
52C614CB |
Front(2F) rack |
1 |
ixv1 |
52C614DB |
IX(2F) 1st rack |
2 |
ixv2 |
52C614CC |
IX(2F) 2nd rack |
3 |
iyv1 |
52C614CA |
IY(2F) 1st rack |
4 |
iyv2 |
52C614CD |
IY(2F) 2st rack |
5 |
IXVbooth |
52C6199D |
IX(2F) booth |
6 |
IYVbooth |
52C6199C |
IY(2F) booth |
7 |
Mozumi
Name |
Serial # |
Location |
koki # |
SVR |
52C61229 |
Mozumi server room rear |
1 |
在庫リスト
Last update: Jam.28th, 2019 by Yokozawa. 子機10個を追加購入 Jan. 11th, 2019 by Yokozawa. 新ラック等に子機インストール、親機の追加
在庫は低音機械室のテント(手前側)に保管。
Name |
Number of stock |
親機 |
1 |
中継機 |
4 |
中継機電源 |
9 |
バッテリ付き子機 |
10 |
probeのみ |
7 |
バッテリ |
32 |
Y end
Name |
Serial # |
Location |
Koki # |
old exc |
52C614DA |
Back in Storage |
N/A |