Differences between revisions 1 and 3 (spanning 2 versions)
Revision 1 as of 2017-11-27 21:39:25
Size: 1125
Comment:
Revision 3 as of 2017-11-27 21:41:59
Size: 1380
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
* Measured IMC length: 53.3 m
http://klog.icrr.u-tokyo.ac.jp/osl/?r=616
 * Measured IMC length: 53.3 m
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=616
Line 7: Line 7:
* Measured IMC mode matching ratio: 86.2 %
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=5019
 * Measured IMC mode matching ratio: 86.2 %
  * https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=5019
Line 11: Line 11:
* Measured MCe RoC: 37.33(9) m
http://klog.icrr.u-tokyo.ac.jp/osl/?r=711
 * Measured MCe RoC: 37.33(9) m
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=711
Line 14: Line 14:
* Measured AOM actuation efficiency: 5.064(7) MHz/V
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3172
 * Measured AOM actuation efficiency: 5.064(7) MHz/V
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3172
Line 17: Line 17:
* Measured MCe actuation efficiency: 6.9 um/V
(any data for MCi and MCo?)
http://gwclio.icrr.u-tokyo.ac.jp/lcgtsubgroup/inoutoptics/2015/06/mce625-26.html#comments
 * Measured MCe actuation efficiency: 6.9 um/V (any data for MCi and MCo?)
  * http://gwclio.icrr.u-tokyo.ac.jp/lcgtsubgroup/inoutoptics/2015/06/mce625-26.html#comments
Line 21: Line 20:
*  * Calibrated IMC WFS noise level, and some noise hunting:
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3366
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3335
Line 23: Line 24:
* Calibrated IMC WFS noise level, and some noise hunting:
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3366
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3335
 * Accelerometer on the PSL table:
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3373
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3435
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3689
Line 27: Line 29:
* Accelerometer on the PSL table:
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3373
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3435
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3689
 * IMC length Noise``Budget code:
  * (UPDATE SVN)
Line 32: Line 32:
* IMC length NoiseBudget code:
(UPDATE SVN)
 * Frequency stabilization servo modeling (design):
  * https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=3330
  * https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=2908

IMC Information

(Could be slightly different right now since we had re-installation work after this measurement)

(Could be fairly different right now since we had re-installation work after this measurement)

KAGRA/Commissioning/CommissioningWorkshop2017/IMCInfo (last edited 2017-11-28 19:23:27 by TomotadaAkutsu)