Size: 1129
Comment:
|
Size: 1374
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 2: | Line 2: |
Line 4: | Line 3: |
http://klog.icrr.u-tokyo.ac.jp/osl/?r=616 (Could be slightly different right now since we had re-installation work after this measurement) |
* http://klog.icrr.u-tokyo.ac.jp/osl/?r=616 (Could be slightly different right now since we had re-installation work after this measurement) |
Line 8: | Line 6: |
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=5019 (Could be fairly different right now since we had re-installation work after this measurement) |
* https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=5019 (Could be fairly different right now since we had re-installation work after this measurement) |
Line 12: | Line 9: |
http://klog.icrr.u-tokyo.ac.jp/osl/?r=711 | * http://klog.icrr.u-tokyo.ac.jp/osl/?r=711 |
Line 15: | Line 12: |
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3172 | * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3172 |
Line 18: | Line 15: |
http://gwclio.icrr.u-tokyo.ac.jp/lcgtsubgroup/inoutoptics/2015/06/mce625-26.html#comments | * http://gwclio.icrr.u-tokyo.ac.jp/lcgtsubgroup/inoutoptics/2015/06/mce625-26.html#comments |
Line 21: | Line 18: |
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3366 http://klog.icrr.u-tokyo.ac.jp/osl/?r=3335 |
* http://klog.icrr.u-tokyo.ac.jp/osl/?r=3366 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3335 |
Line 25: | Line 22: |
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3373 http://klog.icrr.u-tokyo.ac.jp/osl/?r=3435 http://klog.icrr.u-tokyo.ac.jp/osl/?r=3689 |
* http://klog.icrr.u-tokyo.ac.jp/osl/?r=3373 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3435 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3689 |
Line 29: | Line 26: |
* IMC length Noise``Budget code: (UPDATE SVN) |
* IMC length NoiseBudget code: * (UPDATE SVN) * Frequency stabilization servo modeling (design): * https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=3330 * https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=2908 |
IMC Information
- Measured IMC length: 53.3 m
http://klog.icrr.u-tokyo.ac.jp/osl/?r=616 (Could be slightly different right now since we had re-installation work after this measurement)
- Measured IMC mode matching ratio: 86.2 %
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=5019 (Could be fairly different right now since we had re-installation work after this measurement)
- Measured MCe RoC: 37.33(9) m
- Measured AOM actuation efficiency: 5.064(7) MHz/V
- Measured MCe actuation efficiency: 6.9 um/V (any data for MCi and MCo?)
- Calibrated IMC WFS noise level, and some noise hunting:
- Accelerometer on the PSL table:
IMC length NoiseBudget code:
- (UPDATE SVN)
- Frequency stabilization servo modeling (design):