Differences between revisions 6 and 9 (spanning 3 versions)
Revision 6 as of 2017-11-27 22:04:57
Size: 1926
Comment:
Revision 9 as of 2017-11-27 22:15:37
Size: 2413
Comment:
Deletions are marked like this. Additions are marked like this.
Line 29: Line 29:
 * Measured laser PZT actuation efficiency: 1.48MHz/V
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=2853

 * Measured laser temperature actuation efficiency:
  * ???
Line 32: Line 38:

 * Measured IMC optical gain: 18.6 V/MHz (cavity pole=5.6kHz)
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=2979

 * Reference Cavity parameters:
  * ???
Line 43: Line 55:
  * (UPDATE SVN)   * https://granite.phys.s.u-tokyo.ac.jp/svn/LCGT/trunk/kagranoisebudget/FSS/IOO.slx
  * https://granite.phys.s.u-tokyo.ac.jp/svn/LCGT/trunk/kagranoisebudget/FSS/IOO_params.mat

IMC Information