IMC Information
- Measured IMC length: 53.3 m
http://klog.icrr.u-tokyo.ac.jp/osl/?r=616 (Could be slightly different right now since we had re-installation work after this measurement)
- Measured IMC mode matching ratio: 86.2 %
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=5019 (Could be fairly different right now since we had re-installation work after this measurement)
- Measured MCe RoC: 37.33(9) m
http://klog.icrr.u-tokyo.ac.jp/osl/?r=711
- Measured AOM actuation efficiency: 5.064(7) MHz/V
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3172
- Measured MCe actuation efficiency: 6.9 um/V (any data for MCi and MCo?)
http://gwclio.icrr.u-tokyo.ac.jp/lcgtsubgroup/inoutoptics/2015/06/mce625-26.html#comments
- Calibrated IMC WFS noise level, and some noise hunting:
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3366 http://klog.icrr.u-tokyo.ac.jp/osl/?r=3335
- Accelerometer on the PSL table:
http://klog.icrr.u-tokyo.ac.jp/osl/?r=3373 http://klog.icrr.u-tokyo.ac.jp/osl/?r=3435 http://klog.icrr.u-tokyo.ac.jp/osl/?r=3689
IMC length NoiseBudget code:
(UPDATE SVN)