179
Comment:
|
1297
|
Deletions are marked like this. | Additions are marked like this. |
Line 5: | Line 5: |
* MICH LOCK flag * K1:GRD-LSC_LOCK_STATE_N (16Hz sampling) * 1000 is operation mode |
|
Line 6: | Line 10: |
* K1:CAL-CS_CALHWI_CW_INJ_SW (on:1 off:0) | * (1) K1:CAL-CS_CALHWI_CW_INJ_SW (16Hz sampling, on:1 off:0) * Hardware injection switch of CW injection (used in injection flag) * (2) K1:CAL-CS_CALHWI_HWINJ_SW (16Hz sampling, on:1 off:0) * Hardware injection master switch (used in injection flag) * (3) K1:CAL-CS_CALHWI_(X/Y/BS)_GAIN (16Hz sampling) * Signal gain to X, Y, BS * Injection signal * (4) K1:CAL-CS_CAL_HWI_HARDWARE_DQ (16kHz sampling) * Total amplitude of Hardware injection(CBC+CW+TEST) * So, total amplitude of CW injection is * (1)*(2)*(3)*(4) [count] * But, we should apply transfer function between injection port and displacement of each test mass when evaluating the TM displacement * time delay between cal model and BS model (~61usec) * digital anti-imaging filter * time delay in the BS IOP(shared memory for DAC output) (~61usec) * time delay in the DAC output (There is unknown issue) (~60usec???) * The detail is summarized in ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6924 | JGWDoc6924]]) |
Summary of Continuous Wave Injection at bKAGRA phase1 operation
- Worker : T.Yokozawa, A.Miyamoto, T.Sawada
- MICH LOCK flag
- K1:GRD-LSC_LOCK_STATE_N (16Hz sampling)
- 1000 is operation mode
- K1:GRD-LSC_LOCK_STATE_N (16Hz sampling)
- Injection flag
- (1) K1:CAL-CS_CALHWI_CW_INJ_SW (16Hz sampling, on:1 off:0)
- Hardware injection switch of CW injection (used in injection flag)
- (2) K1:CAL-CS_CALHWI_HWINJ_SW (16Hz sampling, on:1 off:0)
- Hardware injection master switch (used in injection flag)
- (3) K1:CAL-CS_CALHWI_(X/Y/BS)_GAIN (16Hz sampling)
- Signal gain to X, Y, BS
- (1) K1:CAL-CS_CALHWI_CW_INJ_SW (16Hz sampling, on:1 off:0)
- Injection signal
- (4) K1:CAL-CS_CAL_HWI_HARDWARE_DQ (16kHz sampling)
- Total amplitude of Hardware injection(CBC+CW+TEST)
- So, total amplitude of CW injection is
- (1)*(2)*(3)*(4) [count]
- But, we should apply transfer function between injection port and displacement of each test mass when evaluating the TM displacement
- time delay between cal model and BS model (~61usec)
- digital anti-imaging filter
- time delay in the BS IOP(shared memory for DAC output) (~61usec)
- time delay in the DAC output (There is unknown issue) (~60usec???)
The detail is summarized in (JGWDoc6924)