Differences between revisions 16 and 36 (spanning 20 versions)
Revision 16 as of 2018-05-07 11:55:08
Size: 3908
Comment:
Revision 36 as of 2018-05-10 10:00:05
Size: 5834
Comment:
Deletions are marked like this. Additions are marked like this.
Line 5: Line 5:
 * input power  * Duration
  * officially (as Saito-san mentioned): Apr 28 9:00am to May 7 6:00am (GPS time: 1208908818-1209675618)
 * input power [Kokeyama, Nakano]
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4377
  * 0.93W at PSL output
  * IMC coupling ratio is (1.20-0.72) / (1.20 - 0.25) = 51 %
  * this means 0.93W * 0.51 / 10 / 2 / 2 / 10 = 1.2 mW at REFL, 0.6 mW at REFL RD PD
Line 13: Line 19:
 * vacuum level
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4527
 * suspension and coil driver configurations (difference between the final configuration)
   * RFPD transimpedance measurement was done with RFPD with different S/N.
 * vacuum pressure [info from Y. Saito]
  * Xend 3e-4 Pa (room temp)
  * Xarm 7e-6 Pa
  * Xfront 5e-5 Pa (room temp)
  * Yend 2e-5 Pa (cryo)
  * Yarm ~1e-6 Pa? (no monitors)
  * Yfront 8e-5 Pa (temperature rising started on Apr 28)
  * IMC, BS < ~1e-4 Pa (no monitors)
 * suspension and coil driver configurations (difference between the final configuration in [[KAGRA/Subgroups/VIS/ActuatorDesign|ActuatorDesign]])
  * BS IM and TM use high power coil drivers instead of low power.
  * ETMY MN, IM and TM use high power coil drivers instead of low power.
  * ETMX MN and IM V1/2 use high power coil drivers instead of low power. From May 4 or 5, IM H1/2/3,V3 also uses high power. ETMX TM used the default low power (not cryopayload version).
Line 19: Line 35:
  * slit size ~10mm, at C chamber first, and then A chamber
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=3848
Line 20: Line 38:
  * time delay, resolution ...
  * succeefully monitored the beam under cryo baffles/shields
  * Tcam update frequency ~1sec, resolution [Inoue]
  * Tcam resolution?

  * successfully monitored the beam under cryo baffles/shields
Line 24: Line 43:
 * initial alignment
  * https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7659
Line 31: Line 52:
 * cooling curve (details -> CRY paper)
 * alignment drift during the cool down
 * cooling curve (details -> CRY paper) [Hasegawa?]
  * Platform, MN, IM, TM, shields
 * alignment drift, height change during the cool down
  * height change [Inoue]
  * not much info for alignment drift. O(100)urad in yaw [Izumi]
  * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4176
Line 47: Line 72:
  * for BS [Fujii]
Line 49: Line 75:
 * actuation efficiency drift  * actuation efficiency drift [Yamamoto]
Line 65: Line 91:
  * Michelson was lockable if ETMX/Y angular fluctuation is less than a few urad. Earthquakes shook ETMY to O(100) urad.
Line 77: Line 104:
   * ETMY takes ~2-3 hours to damp enough for locking. ETMX takes ~1 hour.
Line 83: Line 111:
 * differential seismic noise measured by Michelson (3-km CMRR)  * differential seismic noise measured by Michelson (3-km CMRR), GIF-X (1.5-km CMRR), IMC (26.65-m CMRR)
  * CMRR measurement with 3-km Michelson would be difficult
  * IMC CMRR [Nakano]
Line 85: Line 115:

== Data acquisition, data transfer ==
 * latency, speed, total amount

Summary of Phase 1 Measurements

  • Summary of Phase 1 measurements for bKAGRA Phase 1 paper.

Basic configurations

  • Duration
    • officially (as Saito-san mentioned): Apr 28 9:00am to May 7 6:00am (GPS time: 1208908818-1209675618)
  • input power [Kokeyama, Nakano]
  • power at detection RF PD
  • modulation frequency, modulation depth
  • vacuum pressure [info from Y. Saito]
    • Xend 3e-4 Pa (room temp)
    • Xarm 7e-6 Pa
    • Xfront 5e-5 Pa (room temp)
    • Yend 2e-5 Pa (cryo)
    • Yarm ~1e-6 Pa? (no monitors)
    • Yfront 8e-5 Pa (temperature rising started on Apr 28)
    • IMC, BS < ~1e-4 Pa (no monitors)

  • suspension and coil driver configurations (difference between the final configuration in ActuatorDesign)

    • BS IM and TM use high power coil drivers instead of low power.
    • ETMY MN, IM and TM use high power coil drivers instead of low power.
    • ETMX MN and IM V1/2 use high power coil drivers instead of low power. From May 4 or 5, IM H1/2/3,V3 also uses high power. ETMX TM used the default low power (not cryopayload version).

Michelson initial alignment

  • details of slit method
  • Tcam and baffle PD performance (details-> Tcam paper)

    • Tcam update frequency ~1sec, resolution [Inoue]
    • Tcam resolution?
    • successfully monitored the beam under cryo baffles/shields

Installation accuracy

Cryogenics

  • cooling curve (details -> CRY paper) [Hasegawa?]

    • Platform, MN, IM, TM, shields
  • alignment drift, height change during the cool down

Suspension characterization

Sensitivity and stability

Seismic noise, arm length drift

Data acquisition, data transfer

  • latency, speed, total amount

Hardware injection test

  • CBC injection(2018/4/30 Night shift)
  • CW injection(2018/5/2 Night shift)