Size: 2255
Comment:
|
Size: 2703
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 29: | Line 29: |
* length actuation efficiency measurements for BS, comparison with expectations (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4811) | * length actuation efficiency measurements for BS, comparison with expectations * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4811 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4909 |
Line 31: | Line 33: |
* http://klog.icrr.u-tokyo.ac.jp/osl/?r=4898 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4899 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4919 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4925 * seismic attenuation ratio measurements for ETMY and Y * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4927 |
|
Line 39: | Line 47: |
* Noise budget (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4834) | * Noise budget * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4834 * http://klog.icrr.u-tokyo.ac.jp/osl/?r=4910 |
Line 41: | Line 51: |
* http://klog.icrr.u-tokyo.ac.jp/osl/?r=4891 |
Summary of Phase 1 Measurements
- Summary of Phase 1 measurements for bKAGRA Phase 1 paper.
Basic configurations
- input power
- power at detection RF PD
Reflection from one end mirror 0.20 mW (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4876)
At dark fringe 56 +/- 10 uW (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4903)
- modulation frequency, modulation depth
16.87293 MHz (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4831)
beta = 0.12 (from error signal amplitude), 0.2 (from RF power applied to EOM) (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4876 , http://klog.icrr.u-tokyo.ac.jp/osl/?r=4907)
- vacuum level
- suspension and coil driver configurations (difference between the final configuration)
Michelson initial alignment
- details of slit method
Tcam and baffle PD performance (details-> Tcam paper)
- time delay, resolution ...
Installation accuracy
- Schunupp asymmetry measurement
- IMC length measurement
53.30299(2) m (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4831)
Cryogenics
cooling curve (details -> CRY paper)
Suspension characterization
- length actuation efficiency measurements for BS, comparison with expectations
- length actuation efficiency measurements for ETMX and Y, comparison with expectations
- seismic attenuation ratio measurements for ETMY and Y
- TF difference between ETMX and ETMY (room temperature and cryogenic)
- vertical to length coupling, other coupling measurements
Sensitivity and stability
- actuation efficiency drift
- alignment drift of suspensions
visibility and optical gain drift (http://klog.icrr.u-tokyo.ac.jp/osl/?r=4775)
sensitivity stability, duty factor, lock duration (similar plots in https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5177)
- Noise budget
magnetic and acoustic noise from PEM injection (details -> PEM paper?)
Seismic noise, arm length drift
seismic spectra stability (similar plots in https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2971)
- differential seismic noise measured by Michelson (3-km CMRR)
- differential arm length drift, correlation between GIF-X