Differences between revisions 24 and 59 (spanning 35 versions)
Revision 24 as of 2018-04-28 17:17:52
Size: 6462
Comment:
Revision 59 as of 2018-04-28 19:04:13
Size: 4769
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
 . <<TableOfContents(2)>>
Line 2: Line 4:
pic  . {{attachment:image1.jpeg||width="1000"}}

 . {{attachment:IMG_4929.jpg||width="430"}}
Line 6: Line 10:
 In the sitemap, you can click on the link for the guardian ovewview screen.
 {{attachment:sitemap_guardian.png||height="172",width="430"}}
 . In the sitemap, you can click on the link for the guardian overview screen.
 {{attachment:sitemap_guardian.png||height="172",width="430"}} <<BR>> It pops up the following screen, <<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}}
Line 9: Line 13:
 <<BR>>
 It pops the foll
owing screen,
 <<BR>>
{{attachment:guardian_howto3.png||height="281",width="434"}}
=== Knowing the current state and requested state ===
 . {{attachment:guardian_howto4.png||height="281",width="434"}}
Line 14: Line 16:
=== Accessing to the guardian screen ===

{{attachment:guardian_howto4.png||height="281",width="434"}}


{{attachment:guardian_howto.png||height="298",width="433"}}

{{attachment:guardian_howto2.png||height="299",width="434"}}
=== How to request a state ===
 . Click on the gray bar in the middle.<<BR>> {{attachment:guardian_howto.png||height="298",width="433"}} <<BR>> Then, choose the desired state.<<BR>> {{attachment:guardian_howto2.png||height="299",width="434"}}
Line 24: Line 20:
 * Look at the monitor here. If "ON", it is in OPERATION mode. If "OFF", it is not; something is strange

screen shots

 * If "OFF", check this screen

screen shots

 
1. Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.

Screen shot

 2. If the state is
READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION, or ACTUATORCAL_INJECTION, the interferometer is now on the way to be OPERATION state. It will be ready soon. If it will not enter OPERATION state in a few mins, something is wrong. Call interferometer experts.
  . If it is in DOWN state, go to 3.

 2.
Check the status of IMC_LOCK, VIS_BS, VIS_PR2, VIS_PR3. (Note that VIS_PRM is not used for now, so just ignore it) -- For IMC_LOCK, every thing should be green and IMC should be back automatically. If it will not come back in ~ 10 mins, call interferomter/IOO experts. -- For VIS_PR2 and VIS_BS, the state should be ALIGNED. If it is not, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog. -- For VIS_PR3, the state should be DAMPED. If it is not, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog.
 . Look at one of the TV monitor in the control room. If "ON", it is in OPERATION mode.
 {{attachment:obs_state.png||height="233",width="465"}} <<BR>>
If "OFF", check the guardian overview screen<<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}} <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>> {{attachment:guardian_howto4.png||height="281",width="434"}}
 . If the state is ''READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION'', or ''ACTUATORCAL_INJECTION'', the interferometer is now on the way to be OPERATION state. It will be ready soon. <<BR>> /!\ ''' If it does not enter OPERATION state in a few mins. Call the interferometer experts.'''<<BR>> Check the status of ''IMC_LOCK, VIS_BS, VIS_PR2, VIS_PR3''. (Note that ''VIS_PRM'' is not used for now, so just ignore it) <<BR>>For IMC_LOCK, every thing should be green and IMC should be back automatically. <<BR>> {{attachment:IMC_guardian.png||height="293",width="453"}} <<BR>> For example, this is how the IMC_LOCK guardian should normally look like.<<BR>> {{attachment:IMC_guardian_status.png||height="281",width="407"}} <<BR>> /!\ '''If it does not come back in ~ 10 mins, call interferometer/IOO experts.'''<<BR>> For VIS_PR2 and VIS_BS, the state should be ALIGNED. If inot, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog. <<BR>> For VIS_PR3, the state should be DAMPED. If it is not, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog.
Line 42: Line 25:
0. Request LSC_MICH to be READY by Guardian.  0. Request LSC_MICH to be READY by Guardian.
Line 44: Line 27:
1. Open Sitemap (from Terminal, type "mk" and press return).  0. Open Sitemap (from Terminal, type "mk" and press return).
Line 46: Line 29:
2. Click VIS  0. Click VIS
Line 48: Line 31:
3. Click the suspension of which you want to reset Watch Dog  0. Click the suspension of which you want to reset Watch Dog
 {{attachment:VISALL.png||width="407"}} <<BR>>
Line 50: Line 34:
screenshot  0. Go to PRs case or BS case
Line 53: Line 37:
4. Request SAFE by Guardian  4. Request SAFE by Guardian
Line 55: Line 39:
5. Open "DETAILS" at bottom right  4. Open "DETAILS" at bottom right,
 {{attachment:PRTOP.png||width="300"}} <<BR>>
  . and you will find PRs overview screen
 {{attachment:PR.png||width="800"}} <<BR>>
Line 57: Line 44:
6. Click WATCHDOG here.  4. Click WATCHDOG
  . If something is red, press here to reset.
 {{attachment:PRWD.png||width="400"}} <<BR>>
Line 59: Line 48:
pic  4. Click DACKILL (see the picture above, PRs overview sceen)
  . If it is not green, press reset.
 {{attachment:DACKILL.png||width="200"}} <<BR>>
Line 61: Line 52:
 . If something is red, press here to reset.  4. Click Coil Driver WD (picture above, PRs overview sceen) Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button
 {{attachment:PR_CDWD.png||width="800"}} <<BR>>
Line 63: Line 55:
7. Click DACKILL here.  4. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.
Line 65: Line 57:
pic pic

 . If it is not green, press reset.

8. Click this button

pic

 . Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button

pic

9. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.

10. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.
 4. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.
Line 82: Line 60:
4. Request SAFE by Guardian  4. Request SAFE by Guardian
Line 84: Line 62:
5. Open "Payload" at bottom right  4. Open "Payload" at bottom center,
 {{attachment:BSTOP.png||width="250"}} <<BR>>
  . and you will find BS payload overview screen
 {{attachment:BSpayload.png||width="800"}} <<BR>>
Line 86: Line 67:
6. Click WATCHDOG here.  4. Click WATCHDOG If something is red, press here to reset.
 {{attachment:PRWD.png||width="400"}} <<BR>>
Line 88: Line 70:
pic  4. Click DACKILL (see the picture above for BS overview screen) If it is not green, press reset.
 {{attachment:DACKILL.png||width="200"}} <<BR>>
Line 90: Line 73:
 . If something is red, press here to reset.  4. Click Coil Driver WD (see the picture above for BS overview screen) Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button
 {{attachment:PR_CDWD.png||width="800"}} <<BR>>
Line 92: Line 76:
7. Click DACKILL here.  4. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.
Line 94: Line 78:
pic pic

 . If it is not green, press reset.

8. Click this button

pic

 . Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button

pic

9. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.

10. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

=== basic tasks ===
 * you have to take the logbook to report the incident during the observation shift (see [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Observation/iKAGRA/Manual/MIF|IFO Operational Manual]])

 * you have to check the check list to avoid mistake during the observation shift ([[http://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0049/T1604975/005/CheckList_20160324.pdf|Check List]])

ここから先は観測シフトの仕事を簡単にまとめたものです。まだ暫定的なメモのような状態なので、適宜アップデートして下さい。ここは分かりやすさのために日本語で書きます。余裕のある方は英語版も作って下さい。

[General]

 * まずコントロールルームのPCのapplication→terminal→mk→sitemapが開かれる

[DGS]

 * sitemap→CDS→DAQが全部緑になっているかどうかを確認。緑じゃなければその項目のボタンを押し、statusが0×0になっているか確認。なっていなれけば宮川さんか苔山さんに連絡。

[MIF]

 * sitemap→guardian→MICH_LOCKとIMC_LOCKを確認。PSLは3月中は触らない。(IMCがロックしていればIMC_MCI_TRANS_OUTPUTは0.35くらい)

[VIS]

 * sitemap→VIS→PR3の画面右側のWATCHDOG、DACKILL IOPが緑かどうかを確認。

[DMG]

 * DMG Check-Sheetを2時間おきに書く。コントロールルーム隣のサーバールームのPCを見て、Check-SheetのIn case of normalを満たしているか確認。Is the log outputs normal?は、PC画面に赤か黄のメッセージが出てこなければOK。

[klog]

 * klogに干渉計の状況を簡単に報告。

=== useful information ===
 * terminology

||<#F0F0FF>Abbreviation / Acronym ||<#F0F0FF>Meaning / Explanation ||
||BS ||Beam Splitter ||
||CDS || ||
||DAQ ||Data Acquisition ||
||DAS ||Data Analysis ||
||DC ||Direct Current ||
||DET/Detchar ||Detector Characterization ||
||DGS ||Digital System ||
||DMG ||Data Management ||
||EPICS ||Experimental Physics and Industrial Control System ||
||EX/ETMX ||X Arm End Test Mass ||
||EY/ETMY ||Y Arm End Test Mass ||
||FCL ||Facility ||
||GAS ||Geometric Anti-Spring ||
||GIF ||Geophysics Interferometer ||
||Guardian ||Automation system for interferometers ||
||IFO ||Interferometer Optics ||
||IMC ||Input Mode Cleaner ||
||LSC ||Length Sensing and Control, especially for MIF ||
||MCi/e/o ||Name of three mirrors of IMC; Input, End, and Output mirrors ||
||Medm ||GUI for dealing with EPICS ||
||MI ||Michealson Interferometer ||
||MIF ||Main Interferometer ||
||OpLev ||Optical Lever; measures angle of a mirror ||
||OSEM ||Optical Sensor and ElectroMagnet ||
||PMC ||Pre-Mode Cleaner ||
||PR3 ||Type Bp’ SAS. works as the last steering mirror for MI ||
||PSL ||Pre-Stabilized Laser ||
||SAS ||Seismic Attenuation System ||
||TM ||Test Mass ||
||VAC ||Vacuum ||
||VIS ||Vibration Isolation System ||


 * how to search JGW document
 4. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

Control Room Overview

How to use Guardian

Accessing to the guardian screen

Knowing the current state and requested state

How to request a state

How to know the status of the interferometer

How to reset Watch Dogs

  1. Request LSC_MICH to be READY by Guardian.
  2. Open Sitemap (from Terminal, type "mk" and press return).
  3. Click VIS
  4. Click the suspension of which you want to reset Watch Dog

    VISALL.png

  5. Go to PRs case or BS case

PRs case

  1. Request SAFE by Guardian
  2. Open "DETAILS" at bottom right,

    PRTOP.png

    • and you will find PRs overview screen

    PR.png

  3. Click WATCHDOG
    • If something is red, press here to reset.

    PRWD.png

  4. Click DACKILL (see the picture above, PRs overview sceen)
    • If it is not green, press reset.

    DACKILL.png

  5. Click Coil Driver WD (picture above, PRs overview sceen) Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button

    PR_CDWD.png

  6. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.
  7. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

BS case

  1. Request SAFE by Guardian
  2. Open "Payload" at bottom center,

    BSTOP.png

    • and you will find BS payload overview screen

    BSpayload.png

  3. Click WATCHDOG If something is red, press here to reset.

    PRWD.png

  4. Click DACKILL (see the picture above for BS overview screen) If it is not green, press reset.

    DACKILL.png

  5. Click Coil Driver WD (see the picture above for BS overview screen) Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button

    PR_CDWD.png

  6. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.
  7. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

KAGRA/Commissioning/Phase1/Operation/ShiftManual (last edited 2018-04-28 19:04:13 by YutaroEnomoto)