Differences between revisions 30 and 35 (spanning 5 versions)
Revision 30 as of 2018-04-28 17:39:07
Size: 6611
Comment:
Revision 35 as of 2018-04-28 17:50:27
Size: 6793
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
 <<TableOfContents(2)>>
Line 6: Line 8:
 . In the sitemap, you can click on the link for the guardian ovewview screen.  . In the sitemap, you can click on the link for the guardian overview screen.
Line 14: Line 16:
 . Click on the gray bar in the middle.<<BR>> {{attachment:guardian_howto.png||height="298",width="433"}}  . Click on the gray bar in the middle.<<BR>> {{attachment:guardian_howto.png||height="298",width="433"}}<<BR>>
Line 21: Line 23:
 * If "OFF", check this screen  <<BR>>If "OFF", check the guardian overview screen<<BR>>
Line 23: Line 25:
screen shots  {{attachment:guardian_howto3.png||height="281",width="434"}}
Line 25: Line 27:
 1. Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.  <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>>
Line 27: Line 29:
Screen shot  {{attachment:guardian_howto4.png||height="281",width="434"}}
Line 29: Line 31:
 2. If the state is READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION, or ACTUATORCAL_INJECTION, the interferometer is now on the way to be OPERATION state. It will be ready soon. If it will not enter OPERATION state in a few mins, something is wrong. Call interferometer experts.   If the state is ''READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION'', or ''ACTUATORCAL_INJECTION'', the interferometer is now on the way to be OPERATION state. It will be ready soon.

  <<BR>> /!\ ''' If it does not enter OPERATION state in a fe
w mins. Call the interferometer experts.'''

Control Room Overview

pic

How to use Guardian

Accessing to the guardian screen

Knowing the current state and requested state

How to request a state

How to know the status of the interferometer

How to reset Watch Dogs

0. Request LSC_MICH to be READY by Guardian.

1. Open Sitemap (from Terminal, type "mk" and press return).

2. Click VIS

3. Click the suspension of which you want to reset Watch Dog

screenshot

PRs case

4. Request SAFE by Guardian

5. Open "DETAILS" at bottom right

6. Click WATCHDOG here.

pic

7. Click DACKILL here.

pic pic

8. Click this button

pic

pic

9. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.

10. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

BS case

4. Request SAFE by Guardian

5. Open "Payload" at bottom center

6. Click WATCHDOG here.

pic

7. Click DACKILL here.

pic pic

8. Click this button

pic

pic

9. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.

10. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

basic tasks

ここから先は観測シフトの仕事を簡単にまとめたものです。まだ暫定的なメモのような状態なので、適宜アップデートして下さい。ここは分かりやすさのために日本語で書きます。余裕のある方は英語版も作って下さい。

[General]

[DGS]

[MIF]

[VIS]

[DMG]

[klog]

useful information

Abbreviation / Acronym

Meaning / Explanation

BS

Beam Splitter

CDS

DAQ

Data Acquisition

DAS

Data Analysis

DC

Direct Current

DET/Detchar

Detector Characterization

DGS

Digital System

DMG

Data Management

EPICS

Experimental Physics and Industrial Control System

EX/ETMX

X Arm End Test Mass

EY/ETMY

Y Arm End Test Mass

FCL

Facility

GAS

Geometric Anti-Spring

GIF

Geophysics Interferometer

Guardian

Automation system for interferometers

IFO

Interferometer Optics

IMC

Input Mode Cleaner

LSC

Length Sensing and Control, especially for MIF

MCi/e/o

Name of three mirrors of IMC; Input, End, and Output mirrors

Medm

GUI for dealing with EPICS

MI

Michealson Interferometer

MIF

Main Interferometer

OpLev

Optical Lever; measures angle of a mirror

OSEM

Optical Sensor and ElectroMagnet

PMC

Pre-Mode Cleaner

PR3

Type Bp’ SAS. works as the last steering mirror for MI

PSL

Pre-Stabilized Laser

SAS

Seismic Attenuation System

TM

Test Mass

VAC

Vacuum

VIS

Vibration Isolation System

KAGRA/Commissioning/Phase1/Operation/ShiftManual (last edited 2018-04-28 19:04:13 by YutaroEnomoto)