Differences between revisions 13 and 19 (spanning 6 versions)
Revision 13 as of 2019-12-25 12:08:58
Size: 1056
Editor: miyoki
Comment:
Revision 19 as of 2019-12-25 13:14:19
Size: 1304
Editor: miyoki
Comment:
Deletions are marked like this. Additions are marked like this.
Line 4: Line 4:
||Temperature fluctuation monitoring <<BR>> and remote adjustment|| Monitor: Use PEM' monitors <<BR>> Control: two heaters in the corner station <<BR>> Control: two heaters in the Yend station|| - Get temp change without any human action in KAGRA <<BR>> - Adjust temp within +/- 0.1C ||-[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12300 |klog12300]] <BR>-[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12294 |klog12294]] || ||Temperature fluctuation monitoring <<BR>> and remote adjustment|| Monitor: Use PEM' monitors <<BR>> Control: two heaters in the corner station <<BR>> Control: two heaters in the Yend station|| - Get temp change without any human action in KAGRA <<BR>> - Adjust temp within +/- 0.1C ||[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12300 |klog12300]] <<BR>>[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12294 |klog12294]] ||
Line 7: Line 7:
||FFU vibration investigation|| Stop FFUs according to [[KAGRA/EngineeringRun/ER191217_24/postERtrial| post ER action ]] || - Check FFUs influence || -[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12296 | klog12296]]  || ||FFU vibration investigation|| Stop FFUs according to [[KAGRA/EngineeringRun/ER191217_24/postERtrial| post ER action ]] || - Check FFUs influence || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12296 | klog12296]] <<BR>> [[ http://klog.icrr.u-tokyo.ac.jp/osl/?r=12297 | klog12297 ]] ||
||temp change with much less FFUs operation || Check the temp change trend || Future data for temp compensation || [[ http://klog.icrr.u-tokyo.ac.jp/osl/?r=12283 | klog12283 ]] ||

FCL Themes, Actions and Goals

Theme

Targets

Goals

Results and Homeworks for future

Temperature fluctuation monitoring 
and remote adjustment

Monitor: Use PEM' monitors
Control: two heaters in the corner station
Control: two heaters in the Yend station

- Get temp change without any human action in KAGRA
- Adjust temp within +/- 0.1C

klog12300
klog12294

Water situation monitoring

Sent water amount data automatically
via e-mail to FLC members

- Stable mail sending

- no problems

Air Compressor Mitigation

Stop air compressor btw IXC and IXA

- Check removal of excitation and data quality enhancement

-klog***

FFU vibration investigation

Stop FFUs according to post ER action

- Check FFUs influence

klog12296
klog12297

temp change with much less FFUs operation

Check the temp change trend

Future data for temp compensation

klog12283

KAGRA/EngineeringRun/ER191217_24/FCL (last edited 2019-12-25 13:14:19 by miyoki)