738
Comment:
|
419
|
Deletions are marked like this. | Additions are marked like this. |
Line 3: | Line 3: |
||'''Theme'''|| '''Targets''' || '''Goals '''||'''Results and Homeworks for future''' || ||Temperature fluctuation monitoring <<BR>> and remote adjustment|| Monitor: Use PEM' monitors <<BR>> Control: two heaters in the corner station <<BR>> Control: two heaters in the Yend station|| - Get temp change without any human action in KAGRA <<BR>> - Adjust temp within +/- 0.1C ||-[[ |klog***]] || ||Water situation monitoring ||Sent water amount data automatically <<BR>> via e-mail to FLC members|| - Stable mail sending || -[[ |klog***]] || ||Air Compressor Mitigation|| Stop air compressor btw IXC and IXA || - Check removal of excitation and data quality enhancement || -[[ |klog***]] || |
||'''Theme'''|| '''Targets''' ||'''Results and Homeworks for future''' || || IFO stable operation || Longer locking || -[[ |klog***]] || || IFO stable sensitivity || Longer good sensitivity || -[[ |klog***]] || || IFO locking || Reliable and quick recovery || -[[ |klog***]] || || Tidal and alignment drift evaluation || LSC/ASC Control Loop evaluation || -[[ |klog***]] || |
IFO Themes, Actions and Goals