Line 3: | Line 3: |
* Noise investigation about FFUs in the corner stations * Method 1. Make marks on FFU switches that are not turned off in MCE, IFI, PRM, PR3, PR2, BS, SR2, SR3, SRM, OMC with "Pink Tape".<<BR>> (Operated FFU / Total FFU) list is,<<BR>> || area name ||MCE || IFI || PRM || PR3 || PR2 || BS || SR2 || SR3 || SRM || OMC || |
* Noise investigation about FFUs in the corner stations by an operator. 1. Preparation *Make marks on FFU switches that are not turned off in MCE, IFI, PRM, PR3, PR2, BS, SR2, SR3, SRM, OMC with "Pink Tape".<<BR>> (Operated FFU / Total FFU) table list is below.<<BR>>130 FFUs will be turned off. This corresponds to 26kW heating power.<<BR>>26kW corresponds to about two water cooler cooling power (2 x 14kW). * Method(1) * Take a sensitivity by an operator. * 4 people stand by (MCE, IFI, PRM), (PR3, PR2, BS), (SR2, SR3), (SRM OMC) FFU switchs. * Turn off almost FFUs at the same time by 4 people, except for pink one. * Take the sensitivity again before alignment will change. * Check the difference btw FFU operation and almost no FFU operation. || Area Name ||MCE || IFI || PRM || PR3 || PR2 || BS || SR2 || SR3 || SRM || OMC || |
Line 8: | Line 16: |
<<BR>> 1.#2 4 people stand by (MCE, IFI, PRM), (PR3, PR2, BS), (SR2, SR3), (SRM OMC) FFU switchs. * Keep taking sensitivity of FPMI condition by an operator. * Turn off almost FFUs at the same time by 4 people, except for pink one. * Check the difference btw FFU operation and alnost-no operation. |
1.#3 Method(2) |
Plans for trial just after ER
- Noise investigation about FFUs in the corner stations by an operator.
- Preparation
Make marks on FFU switches that are not turned off in MCE, IFI, PRM, PR3, PR2, BS, SR2, SR3, SRM, OMC with "Pink Tape".
(Operated FFU / Total FFU) table list is below.
130 FFUs will be turned off. This corresponds to 26kW heating power.
26kW corresponds to about two water cooler cooling power (2 x 14kW).
- Method(1)
- Take a sensitivity by an operator.
- 4 people stand by (MCE, IFI, PRM), (PR3, PR2, BS), (SR2, SR3), (SRM OMC) FFU switchs.
- Turn off almost FFUs at the same time by 4 people, except for pink one.
- Take the sensitivity again before alignment will change.
- Check the difference btw FFU operation and almost no FFU operation.
Area Name
MCE
IFI
PRM
PR3
PR2
BS
SR2
SR3
SRM
OMC
Operation/Total
2/16
2/12
2/12
4/16
4/20
4/20
4/20
4/16
4/16
4/16
- Method(2)
- Preparation