Size: 1525
Comment:
|
Size: 2293
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
* Suspensions | * Suspensions(R.Takahashi) |
Line 6: | Line 6: |
* Coil resistances | * Coil resistances and inductances * MCo: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28668 *MCi/e: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28696 |
Line 8: | Line 10: |
* MCo: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28911 * MCe: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28910 * POM: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28914 |
|
Line 13: | Line 18: |
* Health MCo: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28890 * Health MCi: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28889 * Health MCe: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28915 |
|
Line 15: | Line 23: |
* MCe: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28915 * MCi/o: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28913 |
|
Line 16: | Line 26: |
* Mirror conditions | * Mirror conditions(Y.Aso) |
Line 19: | Line 29: |
* Inspection: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28878 | |
Line 20: | Line 31: |
* Alignment | * Alignment(T.Akutsu, T.Ushiba, T.Yokozawa) |
Line 31: | Line 42: |
*Beam damping | *Beam damping(T.Akutsu) |
Line 35: | Line 46: |
* Vacuum, etc | * Vacuum, etc (N.Kimura, T.Uchiyama, S.Miyoki) |
IMC Ecovery(20240322)
- Suspensions(R.Takahashi)
- Electrical wirings
- Coil resistances and inductances
- Isolation of Wiring from coils to flanges(pico and mag-coil)
- Fixing on tables is tight and reliable?
- Mechanical Motion
- Smooth pico motion and its default position
- Smooth Mag-coil motion and balance and TFs
- balance can be adjusted after closing?
Health MCo: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28890
Health MCi: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28889
Health MCe: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28915
- Gaps between magnets and coils
- Gaps between EQ stoppers and mirrors
- Electrical wirings
- Mirror conditions(Y.Aso)
- Clean around the center?
- MCe has a spot near the center. But its influence is expected to be small.
Inspection: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28878
- Clean around the center?
- Alignment(T.Akutsu, T.Ushiba, T.Yokozawa)
- TEM00 flashing
- The IMC trans beam is the same as before?
- Beam positions on each mirror
- They should be the same because the IMC trans was recovered in MCio?
- How about on MCe? MCE tra QPD can be the reference.
- QPD path and centering
- Gaps between magnets and coils again
- IP1/2 dynamic range check for the IMC injection?
- Beam paths for IMC REFL.
- Beam damping(T.Akutsu)
- Beam shield reinstallation
- Beam dampers were additionally added?
- Vacuum, etc (N.Kimura, T.Uchiyama, S.Miyoki)
- Cleaning
- No dust inside, especially on the bottom?
- Leak point was fastened tightly?
- It will be done when the bellows are attached by Mirapro.
- MCE trans flange rotation
- Lift-up tool check for bellows installation.
- Flange surface check to avoid leaking especially on GV_mcf
- FFU stop for the MCE/MCREFL optical table and reconstruction of the window shield (MCE, MCF?).
- Cleaning