Differences between revisions 104 and 123 (spanning 19 versions)
Revision 104 as of 2017-01-20 16:00:40
Size: 4431
Editor: KyosukeAwai
Comment:
Revision 123 as of 2017-12-26 10:44:42
Size: 6148
Comment:
Deletions are marked like this. Additions are marked like this.
Line 6: Line 6:
Members: S.Kawamura (Chair, ICRR), M. Ohashi (ICRR), S.Miyoki (ICRR), N.Ohishi (NAOJ), H.Ishizaki (NAOJ), K.Takayama (ICRR) Members: S.Kawamura (Chair, ICRR), M. Ohashi (ICRR), S.Miyoki (ICRR), T. Uchiyama (ICRR), N.Ohishi (NAOJ), H.Ishizaki (NAOJ), K.Takayama (ICRR), N. Kimura (KEK), K. Awai (ICRR), M. Nakahata (ICRR), M. Shiozawa (ICRR), S. Kimura (Kamioka)
Line 9: Line 9:
Members: M. Ohashi (Chair, ICRR), S.Miyoki (ICRR), T. Uchiyama (ICRR), O. Miyakawa (ICRR), H.Ishitsuka (ICRR), K.Takayama (ICRR) Members: M. Ohashi (Chair, ICRR), S. Kawamura (ICRR), S.Miyoki (ICRR), T. Uchiyama (ICRR), O. Miyakawa (ICRR), K. Awai (ICRR), K.Takayama (ICRR)
Line 28: Line 28:
 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4023|講習(lecture)]]
 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6456|安全講習 (日本語)]]
 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6399|Safety Lecture (English)]]

 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6458|入出坑システム (日本語)]]

 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7325|東京大学宇宙線研究所附属重力波観測研究施設薬品取扱い内規 (日本語)]]

 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6836|避難用空気呼吸器使い方等講習(日本語)]]

 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7311|レーザー安全講習 (日本語)]]
 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7312|Laser Safety Lecture(English)]]
Line 31: Line 42:

 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2816|入坑マニュアル]]
Line 44: Line 53:
== 3. Hazardous Materials == == 3. Hazardous Materials & Laser ==
Line 48: Line 57:
'''Laser'''
||Laser||Place||Max power||Incident power in KAGRA||'''Class in KAGRA exp. rooms'''||
||IR||Laser room||2W(Class 4)||<100mW||Class 3B||
||Green||Optical table near PR2||100mW(Class 3B)||100mW||Class 3B||

'''Protection for each laser class'''
||Laser class||Direct light ||Scattered light||
||Class 3B||Necessary||''Not necessary''||
||Class 4||Necessary|| Necessary ||

Line 50: Line 70:
 [[KAGRA/Safety/Gas|高圧ガス]]<<BR>>  [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6297|高圧ガス管理マニュアル]]<<BR>>
Line 63: Line 83:
 [[KAGRA/Safety/RegularInspections|定期点検]]  [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5253|クレーン月例点検]]<<BR>>
 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5255|フォークリフト月例点検]]<<BR>>
 [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6815|電気設備月例点検]]<<BR>>
Line 77: Line 99:
 [[KAGRA/Safety/Meetings/2013|2013FY]] [[KAGRA/Safety/Meetings/2014|2014FY]] [[KAGRA/Safety/Meetings/2015|2015FY]] [[KAGRA/Safety/Meetings/2016|2016FY]] [[KAGRA/Safety/Meetings/2013|2013FY]] [[KAGRA/Safety/Meetings/2014|2014FY]] [[KAGRA/Safety/Meetings/2015|2015FY]] [[KAGRA/Safety/Meetings/2016|2016FY]]
[[KAGRA/Safety/Meetings/2017|2017FY]]
Line 83: Line 105:

== 10. Safety Review ==

[[KAGRA/Safety/SafetyReview|2017]]

KAGRA Safety

KAGRA建設に必要な安全確保をはかるための方針や助言をPIに提出、またPIから個別の案件への具体的な指示を実行します。 安全確保に必要なルール作成、法令順守やルール運用に関する周知徹底、危険の予知と予防、などの仕事を遂行します。

安全委員会 Members: S.Kawamura (Chair, ICRR), M. Ohashi (ICRR), S.Miyoki (ICRR), T. Uchiyama (ICRR), N.Ohishi (NAOJ), H.Ishizaki (NAOJ), K.Takayama (ICRR), N. Kimura (KEK), K. Awai (ICRR), M. Nakahata (ICRR), M. Shiozawa (ICRR), S. Kimura (Kamioka)

安全管理室 Members: M. Ohashi (Chair, ICRR), S. Kawamura (ICRR), S.Miyoki (ICRR), T. Uchiyama (ICRR), O. Miyakawa (ICRR), K. Awai (ICRR), K.Takayama (ICRR)


News


1. KAGRA Safety Rule and Lecture

2. KAGRA Safety Manual

3. Hazardous Materials & Laser

Laser

Laser

Place

Max power

Incident power in KAGRA

Class in KAGRA exp. rooms

IR

Laser room

2W(Class 4)

<100mW

Class 3B

Green

Optical table near PR2

100mW(Class 3B)

100mW

Class 3B

Protection for each laser class

Laser class

Direct light

Scattered light

Class 3B

Necessary

Not necessary

Class 4

Necessary

Necessary

4. High‐Pressure Gas

5. Regular Inspections

6. Hazard Analysis

7. References

8. Meeting

2013FY 2014FY 2015FY 2016FY 2017FY

9.ヒヤリハット

10. Safety Review

2017

KAGRA/Safety (last edited 2023-11-17 16:26:15 by miyoki)