= TMS-VIS-Y: preparation in Mitaka = * TMS = BRT (beam reducing telescope) + GPT (Gouy phase telescope) ||<>||<>||<>|| ||<>||<>||<>|| == Links to knowledge == * [[KAGRA/subgroup/AOS/TMS-VIS0|The previous preparation of TMS-VIS (for Xend)]] * [[https://gwpo.nao.ac.jp/wiki/ATCstandalone|Standalone Machine in ATC]] * '''Mechanical design''': [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6336|Mechanical design of TMS Vibration Isolation Stage (by Uraguchi-san)]] * '''Ref''': [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6260| design of blade spring for TMS VIS stage (in Japanese) (by Uraguchi-san)]] * '''Ref''': [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5752| mechanical model of TMS VIS (in Japanese) (by Uraguchi-san)]] * '''Ref''': [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8502|TMS VIS coordinate (in Japanese) (by Uraguchi-san)]] * '''Ref''': [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7663|SR Suspension Diagonalization Matrices (by Mark)]] * '''Ref''': [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4155|A Study of Low Frequency Vibration Isolation System for Large Scale Gravitational Wave Detectors (by Sekiguchi)]] == LVDTs == === Polarity & Calibration Factor === * V: postive means that the LVDT outputs positive counts when TMS-VIS moves upward, and so the calibration factors are set. * H: postive means that the LVDT outputs positive counts when TMS-VIS moves positive yaw (counter clock wise from top view), and so the calibration factors are set. ||'''Sensor'''|| Serial#|| polarity || calibration factor [um/cnt]|| || LVDT V1 ||#6 ||-1 ||0.1374 || || LVDT V2 ||#8 ||+1 ||0.1463 || || LVDT V3 ||#9 ||+1 ||0.1456 || || LVDT H1 ||#10 ||-1 ||0.1356 || || LVDT H2 ||#11 ||-1 ||0.1371 || || LVDT H3 ||#12 ||+1 ||0.1473 || == Actuator coils == Be careful! The pin assignment in the Dsub shell or the signal phases would be different from the below, as I needed to once detach the pins when I installed the coils (Akutsu). Note that newly four actuator coils have been made for TMS-VISY after JGW-T1800846. * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8465|Coil inspection report (JGW-T1808465)]] * [[]] * Tanioka-kun's efforts in 2019 === Polarity & Calibration Factor === * V: postive means upward (TMS-VIS moves in upward by inputting positive value to the act coils from MEDM) * H: positive means plus yaw (TMS-VIS moves in counter clock wise from top view by inputting positive value to the act coils from MEDM) ||'''Actuator'''|| polarity ||Serial#|| || COIL V1 ||+ ||#13 || || COIL V2 ||+ ||#15 || || COIL V3 ||+ ||#16 || || COIL H1 ||+ ||#17 || || COIL H2 ||+ ||#1 || || COIL H3 ||+ ||#6 || == Geophones == * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8466|Data sheets of the geophones (JGW-T1808466)]] * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=5024]] || Serical# of L-4C||Vert/Horiz||Naming of the assembled unit||Assembler|| || 404080975 || Vert || TMS-VISY: Geo-V2||Akutsu || || 404080976 || Vert || -(TMS-VISX: Geo-V2)-|| Akutsu || || 404080977 || Vert || || || || 404080978 || Vert || TMS-VISY: Geo-V3||Akutsu || || 404084240 || Vert || TMS-VISY: Geo-V1 (broken??)|| Akutsu || || 404084241 || Vert || -(TMS-VISX: Geo-V3)-|| Akutsu || || 404084242 || Vert || -(TMS-VISX: Geo-V1)-|| Fujii -> Akutsu || || 2 || Horiz|| -(TMS-VISX: Geo-H3)-|| Akutsu -> Uraguchi || || 3 || Horiz|| || || || 4 || Horiz|| -(TMS-VISX: Geo-H1)-|| Akutsu || || 5 || Horiz|| -(TMS-VISX: Geo-H2)-|| Akutsu || || 15 || Horiz|| TMS-VISY: Geo-H1|| Akutsu || || 16 || Horiz|| TMS-VISY: Geo-H2|| Akutsu || || 17 || Horiz|| TMS-VISY: Geo-H3|| Akutsu || == Cabling == * LVDT/Act - (coil wires) - Dsub9M - (Dsub9F - PTFE 2m - Dsub9F) - Dsub9M flange - Flipper cable - Dsub Cable * Geophone - (MIL C 26482 - PTFE 0.5m - Dsub9M) - (Dsub9F - 1.5m PTFE - Dsub9F) - Dsub9M flange - Flipper cable - Dsub Cable * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8452|PTFE cables]] == Task list == *