= 20180904 = * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=6011]] == Today's activities == Workers: Akutsu, Simon, Yano, Ken Tanaka * Checked and adjusted the height * Firstly draw a reference line on a white tape attached to the wall of the 8K shield to easily check where is the center of duct; which was, as written in the klog above, 269mm from the top surface of the breadboard... the nominal number should be 270mm, right?? * Anyway we continued the checking and found the suspended WAB was slightly rolling, so adjusted the roll by the top stages. == Next plan == * Check the height and horizontal position of the WAB. * Check the pitch and yaw of the WAB. * Before moving the WAB suspension to the saving mode, attach the magnet dampers. == Wanted! == * Vertical standing ruler (or Height Gauge)