== Calibration work memo 2018/4/28 09:00- == Site worker : T.Yamamoto(leader), S.Haino, Y.Inoue, S. Tsuchida, A.Miyamoto, T.Yokozawa === Free swinging === * 09:25 Unlock michelson * 9:32 Started line injection to BS * K1:LSC-REFLAIR_A_RF17_Q_ERR_256_DQ (RF signal of PD) * K1:LSC-REFLAIR_B_LF_OUT_256_DQ (DC signal of PD) * K1:CAL-CS_LINE_LINE8_LKIN_OSC_FREQ (injection line frequency) * K1:CAL-CS_LINE_MTRX_1_8 (Amplitude of calibration line) Table of line injection to BS || Time || Freq[Hz] || amp[count] || || 9:25 || 0.0 || 0 || || 9:32 || 0.2 || 5 || || 9:33 || 0.2 || 10 || || 9:34 || 0.2 || 20 || || 9:36 || 0.2 || 100 || || 9:47 || 0.2 || 250 || || 9:53 || 0.2 || 500 || * 10:10 Finish free swining measurement * Offline analysis * /users/CAL/PHASE1/scripts/EllipseFitting.C * Pre-offline best result [[attachment:openloop_best|png]] 2*pi*2A/lambda = 1.00e+11[cnt/m] = 3.00e+14[cnt/strain] * 11:35 Open loop transfer function measurement * template diaggui /users/CAL/PHASE1/templates/DTT/T_OPTF.dtt.xml * 1st measurement : /users/CAL/PHASE1/measurements/DTT/T_OLTF/T_OLTF_180428_114110.xml * 2nd measurement : /users/CAL/PHASE1/measurements/DTT/T_OLTF/T_OLTF_180428_115610.xml * 3rd measurement : /users/CAL/PHASE1/measurements/DTT/T_OLTF/T_OLTF_180428_124641.xml * 12:15 Coil driver transfer function measurement * transfer function measurement between coilout and FC * EXC(K1:VIS-BS_TM_COILOUTF_H4_EXC) MEADURE(K1:VIS-BS_SCMON_TM_H4) * Be careful, channel name is including SC, but connect to FC. * ??:?? Modified calibration model(C00 Strain) * z-8 delay between error and control * optical gain * Discussed about unknown time delay (1block:1/16384=61usec) * 3 known block delay : LSC->BS, DAC, LSC->CAL? * aAA, dAA, aAI, dAI * iKAGRA has 130usec unknown delay... * ??:?? Start Open loop transfer function measurement * with envelop, measurement accuracy becomes much better! * measurements : /users/CAL/PHASE1/measurements/DTT/T_OLTF/T_OLTF_180428_******.xml