Size: 2675
Comment:
|
Size: 3166
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 2: | Line 2: |
|| Bit || Description || 0 || 1 || Comment || | === Engineering Run with X-arm on the 8th June === * Channel name: '''K1:DET-DQ_STATE_VECTOR''' * Sampling rate: 16 Hz * Data type: Unsigned 32bit integer (FR_VECT_4U) ||<#C6D6FE style="text-align:center; ">'''Bit'''||<#C6D6FE style="text-align:center; ">'''Description'''||<#C6D6FE style="text-align:center; ">'''0''' ||<#C6D6FE style="text-align:center; ">'''1'''||<#C6D6FE style="text-align:center; ">'''Comment'''|| |
Line 4: | Line 9: |
|| 1 || Lock flag || Unlocked || Locked || This bit checks K1:GRD-IO_STATE_N (When GRD channel shows 99 or 100, IMC is locked. || || 2 || SDF flag || Not nominal || Nominal || This bit may not work during IMC ER because someone will work on downstream of IMC. || || 3 || Science mode || Not Science mode || Science mode || TY suppose Science mode flag is turned ON by manually after human check. || || 4 || IMC overflow || Overflow || No Overflow || This bit checks error signal port of IMC. (It will check OMC PD for O3.) || || 5 || MCE overflow || Overflow || No Overflow || This bit checks MCE coil out channels. (It will check ETMX for O3.) || || 6 || not used || Overflow || No Overflow || (This bit will check ETMY coil out overflow.) || || 7 || NO Stoch injection || Injection || No injection || This bit check the injection port of the k1calcs, k1calex, and k1caley. || || 8 || NO CBC injection || Injection || No injection || This bit check the injection port of the k1calcs, k1calex, and k1caley. || || 9 || NO Burst injection || Injection || No injection || This bit check the injection port of the k1calcs, k1calex, and k1caley. || || 10 || NO DET injection || Injection || No injection || This bit check the injection port of the k1calcs, k1calex, and k1caley. || || 11 || NO CW injection || Injection || No injection || This bit check the injection port of the k1calcs, k1calex, and k1caley. || |
|| 1 || Lock flag || Unlocked || Locked || This bit checks K1:GRD-LSC_LOCK_STATE_N (When GRD channel shows 31415, Arm cavity is locked). || || 2 || SDF flag || Not nominal || Nominal || This bit checks the setting of the IFO control is nominal or not<<BR>>(It may not work during IMC ER because someone will work on downstream of IMC). || || 3 || Science mode || Not Science mode || Science mode || TY suppose Science mode flag is turned ON by manually after human check<<BR>>(It is automatically turned off when the lock is lost).|| || 4 || not used || - || - || (This bit will check OMC PD overflow for O3.) || || 5 || MCE overflow || Overflow || No overflow || This bit checks MCE coil out overflow. (It will check ETMX for O3.) || || 6 || not used || - || - || (This bit will check ETMY coil out overflow.) || || 7 || NO Stoch injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || 8 || NO CBC injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || 9 || NO Burst injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || 10 || NO DET injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || || 11 || NO CW injection || Injection || No injection || This bit checks the injection port of the k1calcs, k1calex, (and k1caley). || |
Online Data Quality Vector
Engineering Run with X-arm on the 8th June
Channel name: K1:DET-DQ_STATE_VECTOR
- Sampling rate: 16 Hz
- Data type: Unsigned 32bit integer (FR_VECT_4U)
Bit |
Description |
0 |
1 |
Comment |
0 |
Odd Parity |
- |
- |
This is not a data quality information. It is used for checking validation of DQV. |
1 |
Lock flag |
Unlocked |
Locked |
This bit checks K1:GRD-LSC_LOCK_STATE_N (When GRD channel shows 31415, Arm cavity is locked). |
2 |
SDF flag |
Not nominal |
Nominal |
This bit checks the setting of the IFO control is nominal or not |
3 |
Science mode |
Not Science mode |
Science mode |
TY suppose Science mode flag is turned ON by manually after human check |
4 |
not used |
- |
- |
(This bit will check OMC PD overflow for O3.) |
5 |
MCE overflow |
Overflow |
No overflow |
This bit checks MCE coil out overflow. (It will check ETMX for O3.) |
6 |
not used |
- |
- |
(This bit will check ETMY coil out overflow.) |
7 |
NO Stoch injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
8 |
NO CBC injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
9 |
NO Burst injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
10 |
NO DET injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
11 |
NO CW injection |
Injection |
No injection |
This bit checks the injection port of the k1calcs, k1calex, (and k1caley). |
12 |
not assigned yet |
|
|
|
13 |
not assigned yet |
|
|
|
14 |
not assigned yet |
|
|
|
15 |
not assigned yet |
|
|
|
LV Data Quality Flags
Related Documents
JGW-G1809228 How to use SDF