Rehearsal of rehearsal for PEM injection in bKAGRA phase1

Date

2017/12/26

Place

Second floor of X-end

Aims

  • Clarify the problems of PEM injection in second floor of X-end.
  • Check if sensors and actuators work well and their noise level.
    • Confirm whitening filters are necessary or not.
  • Obtain data to check new analysis tools.
  • Noise hunting of seismometer Trillium compact and Trillium 120QA.

Abstract

地震計(Trillium compactとTrillium 120QA)を干渉計に見立てて、PEM injectionをやってみた。

Introduction

背景。いらない?

Method

  • X-end 2階の見取り図。センサー・アクチュエータの配置。写真。
  • 使ったセンサーとアクチュエータ。
    • 差動出力かどうか確認。
    • 地震計: Trillium compact*2 (CH:fooとbar), Trillium 120QA (CH: hoge)

    • 加速度計: KISTLER 8640A5 3個? (CH: hoge)
    • 加振機: NAOJ。型番を調べる。
    • マイク: B&K4188 1個 (CH: hoge)。カラオケマイク 2個 (CH: fooとran)。

    • スピーカ: 小型スピーカ(端山私物), 拡声器
    • ハンマー: コメリで買ったやつ
    • 磁束計: Mag649 (CH:alice), Mag13MCL (CH:Boc)

    • ファンクションジェネレータ: AFG3022C
    • コイル: なし
  • ファンをoffにするとか。

Result

  • 諸々のスペクトルとかコヒーレンスとか。
    • ファンのon/off比較。地震計の距離比較。別の自由度とのコヒーレンス。励起時のスペクトル。
  • カップリング関数。
  • センサー類のノイズレベル。
  • 地震計のスペクトルへのプロジェクション。

Discussion

議論だよ。