Line 18: Line 18:
 * Measuring coupling functions between environmental noise and interferometer signal
 * Measuring environmental noise using several sensors
 * Spectrogram of the interferometer signal during injection
Line 19: Line 23:
 * Narrow down coupling locations
 * Narrow down environmental noise source locations
 * Switch off test
 * Identify line noise sources
 * RF noise measurement around RF modulation sideband frequencies.
  * [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/MIFIOOInterfaces|RF modulation sideband frequency list]]

=== Candidates of measurement points ===
 * PSL
 * IMC (mirrors, refl table)
 * IFI
 * PRM
 * BS
 * ETMX/Y (1F,2F)
 * TMS (both end)
 * WAB
 * Arms
(including racks of each points for control and DAQ.)
Line 22: Line 44:
 * Before bKAGRA phase1 run (Detailed date has not been fixed): Preparation and rehearsal of PEM injection (end-to-end test, maybe without actual injection)
 * After bKAGRA phase1 run (Detailed date has not been fixed): Injection test in tunnel
 * After injection test: Analysis, make report, (if possible) write paper
Line 23: Line 48:
Before bKAGRA phase1 run (Detailed date has not been fixed): Preparation == Sensors and instruments information ==
=== Common ===
||Items||Numbers||Part Number||To be ordered||Ordered||We have||JGW S-number||Comment ||
||Amplifier||1|| QSC RMX5050a||No||No||Yes||N/A|| ||
||Head set||several|| Not known||Yes||No||No||N/A|| ||
||Small accelerometer ||a few|| KISTLER Accelerometer Type 8640A5||No||No||Yes||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7218|S1707218]],[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7219|7219]],[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7221|7221]],[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7222|7222]]|| ||
||Laser accelerometer ||1|| Not known||No||No||Yes?||N/A|| RION ||
||Clay(?) to fix accelerometer ||a few|| Not known||No||No||Yes?||N/A|| ||
||Cables and connectors||many|| Not known||Yes?||No||No?||N/A|| ||
||Low noise filter||1|| Not known||Yes||No||No||N/A||Like SR560. Hand made? ||
||Function generator ||1|| Not known||No?||No||Yes?||N/A|| ||
Line 25: Line 60:
After bKAGRA phase1 run (Detailed date has not been fixed): Injection test in tunnel
Line 27: Line 61:
After injection test: Analysis, make report, (if possible) write paper === Acoustic injection ===
||Items||Numbers||Part Number||To be ordered||Ordered||We have||JGW S-number||Comment ||
||Large speaker||2||JBL JRX212||No||No||Yes||N/A|| [[http://asia.jblpro.com/www/products/portable-market/jrx200-series#.WhbMP0pl93h|URL]] ||
||Small speaker (PZT)||1|| Not known||Yes||No||No||N/A||(If possible) ||
||Microphone||2|| B&K 4188 + pre-amp||No||No||Yes||N/A|| ||
||Seismometer ||1|| Trillium compact 120-SV1||No||No||Yes||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7526|S1707526]]|| ||
||Earplug ||several|| Not known||Yes||No||No||N/A|| ||
||Rubber stack ||8|| Not known||Yes||No||No||N/A||(If possible) ||
||Horn ||1|| Not known||Yes||No||No||N/A|| ||
Line 29: Line 71:
== Sensors information == === Magnetic injection ===
||Items||Numbers||Part Number||To be ordered||Ordered||We have||JGW S-number||Comment ||
||Large Coil||2|| Not known||Yes||No||No||N/A||a few Ohms, ~1 m dia. ||
||Small Coil||1|| Not known||Yes||No||No||N/A||(If possible) ||
||Magnetometer ||2|| Mag-13MCL||No?||No||Yes?||N/A|| [[http://www.bartington.com/Literaturepdf/Datasheets/Mag-13%20DS3143.pdf|URL (pdf)]]||
||Small magnetometer ||2|| Not known||Yes||No||No||N/A||(If possible) ||
Line 31: Line 78:
== Meeting == === Shaker injection ===
||Items||Numbers||Part Number||To be ordered||Ordered||We have||JGW S-number||Comment ||
||Large Magnet coil shaker||1|| Not known||No||No||Yes||N/A||NAOJ ||
||Small PZT shaker||a few|| Not known||Yes||No||No||N/A|| ||
||Mallet||1|| Not known||Yes||No||No||N/A|| ||

=== Others ===
||Items||Numbers||Part Number||To be ordered||Ordered||We have||JGW S-number||Comment ||
||RF antenna||2|| Not known||Yes||No||No||N/A||Could be made ourselves? ||
||RF signal amplifier ||2|| Not known||Yes||No||No||N/A||Could be made ourselves? ||
||RF generator ||1|| Not known||Yes||No||No||N/A||(If possible. Can Moku:Lab be used?) ||
||RF spectrum analyzer ||1|| Not known||No||No||Yes||N/A||Moku:Lab ||

== To be prepared ==
 * CDS (Real time model, DAC, ADC, DQ)
 * Calibration (Sensors, DAC, ADC)
 * Analysis code to calculate coupling function (peaks, comb, broad)
 * Spectrogram tools

== (Part of) to do list ==
 * Obtain S/N on JGWdoc for all PEM related things, e.g. sensors, actuators, amplifiers, non-standard cables.
 * Calibrate sensors and actuators.
  * Consider how to calibrate them.
 * Consider how many DAC, ADC, CH are required at each measurement point.
 * Consider how to connect all instruments.
  *Differential input/output of CDS.
  *Ground problem.
 * Consider how many people are required.
 * Make analysis codes
 * Gather all required instruments listed in above tables.

== Meetings ==
 [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/DET/PEMinjection/bKAGRA-phase1/meeting_20171206|2017/12/06 Kick-off meeting]]
Next meeting is 2017/12/12 13:00--???

== What has been done ==

PEM injection in bKAGRA phase1

(Description will be translated to English at some point)

Aims

bKAGRA phase1 における、

  • 干渉計感度への環境雑音の影響のプロジェクション
  • 散乱光のキャラクタリゼーション
  • 雑音の形態学的スタディ

Injection types

  • Acoustic injection (AcI)
  • Magnetic injection (MaI)
  • Shaking injection (ShI)

What we want to do

Necessary

  • Measuring coupling functions between environmental noise and interferometer signal
  • Measuring environmental noise using several sensors
  • Spectrogram of the interferometer signal during injection

If possible

  • Narrow down coupling locations
  • Narrow down environmental noise source locations
  • Switch off test
  • Identify line noise sources
  • RF noise measurement around RF modulation sideband frequencies.

Candidates of measurement points

  • PSL
  • IMC (mirrors, refl table)
  • IFI
  • PRM
  • BS
  • ETMX/Y (1F,2F)
  • TMS (both end)
  • WAB
  • Arms

(including racks of each points for control and DAQ.)

Schedule

(VERY ROUGH)

  • Before bKAGRA phase1 run (Detailed date has not been fixed): Preparation and rehearsal of PEM injection (end-to-end test, maybe without actual injection)
  • After bKAGRA phase1 run (Detailed date has not been fixed): Injection test in tunnel
  • After injection test: Analysis, make report, (if possible) write paper

Sensors and instruments information

Common

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Amplifier

1

QSC RMX5050a

No

No

Yes

N/A

Head set

several

Not known

Yes

No

No

N/A

Small accelerometer

a few

KISTLER Accelerometer Type 8640A5

No

No

Yes

S1707218,7219,7221,7222

Laser accelerometer

1

Not known

No

No

Yes?

N/A

RION

Clay(?) to fix accelerometer

a few

Not known

No

No

Yes?

N/A

Cables and connectors

many

Not known

Yes?

No

No?

N/A

Low noise filter

1

Not known

Yes

No

No

N/A

Like SR560. Hand made?

Function generator

1

Not known

No?

No

Yes?

N/A

Acoustic injection

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Large speaker

2

JBL JRX212

No

No

Yes

N/A

URL

Small speaker (PZT)

1

Not known

Yes

No

No

N/A

(If possible)

Microphone

2

B&K 4188 + pre-amp

No

No

Yes

N/A

Seismometer

1

Trillium compact 120-SV1

No

No

Yes

S1707526

Earplug

several

Not known

Yes

No

No

N/A

Rubber stack

8

Not known

Yes

No

No

N/A

(If possible)

Horn

1

Not known

Yes

No

No

N/A

Magnetic injection

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Large Coil

2

Not known

Yes

No

No

N/A

a few Ohms, ~1 m dia.

Small Coil

1

Not known

Yes

No

No

N/A

(If possible)

Magnetometer

2

Mag-13MCL

No?

No

Yes?

N/A

URL (pdf)

Small magnetometer

2

Not known

Yes

No

No

N/A

(If possible)

Shaker injection

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Large Magnet coil shaker

1

Not known

No

No

Yes

N/A

NAOJ

Small PZT shaker

a few

Not known

Yes

No

No

N/A

Mallet

1

Not known

Yes

No

No

N/A

Others

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

RF antenna

2

Not known

Yes

No

No

N/A

Could be made ourselves?

RF signal amplifier

2

Not known

Yes

No

No

N/A

Could be made ourselves?

RF generator

1

Not known

Yes

No

No

N/A

(If possible. Can Moku:Lab be used?)

RF spectrum analyzer

1

Not known

No

No

Yes

N/A

Moku:Lab

To be prepared

  • CDS (Real time model, DAC, ADC, DQ)
  • Calibration (Sensors, DAC, ADC)
  • Analysis code to calculate coupling function (peaks, comb, broad)
  • Spectrogram tools

(Part of) to do list

  • Obtain S/N on JGWdoc for all PEM related things, e.g. sensors, actuators, amplifiers, non-standard cables.
  • Calibrate sensors and actuators.
    • Consider how to calibrate them.
  • Consider how many DAC, ADC, CH are required at each measurement point.
  • Consider how to connect all instruments.
    • Differential input/output of CDS.
    • Ground problem.
  • Consider how many people are required.
  • Make analysis codes
  • Gather all required instruments listed in above tables.

Meetings

Next meeting is 2017/12/12 13:00--???

What has been done