PEM injection in bKAGRA phase1

(Description will be translated to English at some point)

Aims

bKAGRA phase1 における、

  • 干渉計感度への環境雑音の影響のプロジェクション
  • 散乱光のキャラクタリゼーション
  • 雑音の形態学的スタディ

Injection types

  • Acoustic injection (AcI)
  • Magnetic injection (MaI)
  • Shaking injection (ShI)

What we want to do

Necessary

  • Measuring coupling functions between environmental noise and interferometer signal
  • Measuring environmental noise using several sensors
  • Spectrogram of the interferometer signal during injection

If possible

  • Narrow down coupling locations
  • Narrow down environmental noise source locations
  • Switch off test
  • Identify line noise sources
  • RF noise measurement around RF modulation sideband frequencies.

Candidates of measurement points

  • PSL
  • IMC (mirrors, refl table)
  • IFI
  • PRM
  • BS
  • ETMX/Y (1F,2F)
  • TMS (both end)
  • WAB
  • Arms

(including racks of each points for control and DAQ.)

Schedule

(VERY ROUGH)

  • Before bKAGRA phase1 run (Detailed date has not been fixed): Preparation and rehearsal of PEM injection (end-to-end test, maybe without actual injection)
  • After bKAGRA phase1 run (Detailed date has not been fixed): Injection test in tunnel
  • After injection test: Analysis, make report, (if possible) write paper

Sensors and instruments information

Common

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Amplifier

1

QSC RMX5050a

No

No

Yes

N/A

Head set

several

Not known

Yes

No

No

N/A

Small accelerometer

a few

KISTLER Accelerometer Type 8640A5

No

No

Yes

S1707218,7219,7221,7222

Laser accelerometer

1

Not known

No

No

Yes?

N/A

RION

Clay(?) to fix accelerometer

a few

Not known

No

No

Yes?

N/A

Cables and connectors

many

Not known

Yes?

No

No?

N/A

Low noise filter

1

Not known

Yes

No

No

N/A

Like SR560. Hand made?

Function generator

1

Not known

No?

No

Yes?

N/A

Acoustic injection

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Large speaker

2

JBL JRX212

No

No

Yes

N/A

URL

Small speaker (PZT)

1

Not known

Yes

No

No

N/A

(If possible)

Microphone

2

B&K 4188 + pre-amp

No

No

Yes

N/A

Seismometer

1

Trillium compact 120-SV1

No

No

Yes

S1707526

Earplug

several

Not known

Yes

No

No

N/A

Rubber stack

8

Not known

Yes

No

No

N/A

(If possible)

Horn

1

Not known

Yes

No

No

N/A

Magnetic injection

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Large Coil

2

Not known

Yes

No

No

N/A

a few Ohms, ~1 m dia.

Small Coil

1

Not known

Yes

No

No

N/A

(If possible)

Magnetometer

2

Mag-13MCL

No?

No

Yes?

N/A

URL (pdf)

Small magnetometer

2

Not known

Yes

No

No

N/A

(If possible)

Shaker injection

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

Large Magnet coil shaker

1

Not known

No

No

Yes

N/A

NAOJ

Small PZT shaker

a few

Not known

Yes

No

No

N/A

Mallet

1

Not known

Yes

No

No

N/A

Others

Items

Numbers

Part Number

To be ordered

Ordered

We have

JGW S-number

Comment

RF antenna

2

Not known

Yes

No

No

N/A

Could be made ourselves?

RF signal amplifier

2

Not known

Yes

No

No

N/A

Could be made ourselves?

RF generator

1

Not known

Yes

No

No

N/A

(If possible. Can Moku:Lab be used?)

RF spectrum analyzer

1

Not known

No

No

Yes

N/A

Moku:Lab

To be prepared

  • CDS (Real time model, DAC, ADC, DQ)
  • Calibration (Sensors, DAC, ADC)
  • Analysis code to calculate coupling function (peaks, comb, broad)
  • Spectrogram tools

(Part of) to do list

  • Obtain S/N on JGWdoc for all PEM related things, e.g. sensors, actuators, amplifiers, non-standard cables.
  • Calibrate sensors and actuators.
    • Consider how to calibrate them.
  • Consider how many DAC, ADC, CH are required at each measurement point.
  • Consider how many people are required.
  • Make analysis codes
  • Gather all required instruments listed in above tables.

Meetings

What has been done

KAGRA/Subgroups/DET/PEMinjection/bKAGRA-phase1 (last edited 2018-07-11 20:03:44 by KojiNagano)