Differences between revisions 12 and 13
Revision 12 as of 2019-08-28 12:24:37
Size: 935
Comment:
Revision 13 as of 2019-08-29 10:31:40
Size: 1750
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
|| Time (JST)      || Time (GPS)    || IFO config || Main channel || klog || Memo ||
|| 2019/08/27 02:09-09:26 || 1250874558 - 1250900778 || Yarm cavity || K1:CAL-CS_PROC_XARM_FREQUENCY_DQ || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10135|10135]] || Silent run ||
|| 2019/08/28 07:54-09:07 || 1250981658 - 1250986038 || FPmi || K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10168|10168]] || Silent run ||
|| Time (JST) || Time (GPS) || IFO config || Main channel            || klog || Memo ||
|| 2019/08/27 02:09-09:26 || 1250874558 - 1250900778 || Yarm cavity || K1:CAL-CS_PROC_XARM_FREQUENCY_DQ            || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10135|10135]] || Silent run ||
|| 2019/08/28 07:54-09:07 || 1250981658 - 1250986038 || FPMI || K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ            || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10168|10168]] || Silent run ||
|| 2019/08/29 07:43-08:46 || 1251067398 - 1251071178 || FPMI || K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ (Some bug) || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10168|10168]] || Silent run ||
Line 14: Line 14:
  * Yarm cavity or FPmi(Fabry-Perot Michelson intereferometer)   * Yarm cavity : Lock the Yarm cavity by feedback to the IMC length (Almost frequency + Yarm length noise)
  * FPMI : Fabry-Perot Michelson interferometer. The h-of-t signal is calculated from DARM displacement
Line 18: Line 19:
  * K1:CAL-CS_PROC_XARM_FREQUENCY_DQ
   * Unit is Hz, because of calculating the IR laser frequency noise
  * K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ
   * DARM displacement [nm or m] there are still some bugs in the online model, I will summarize later
Line 24: Line 29:
  * In the future, we want to do the calibration line injection, PEM injection, add the excitation and check the noise, hardware injection, and so on.
  * We will write following information.

Summary of the morning run

Time (JST)

Time (GPS)

IFO config

Main channel

klog

Memo

2019/08/27 02:09-09:26

1250874558 - 1250900778

Yarm cavity

K1:CAL-CS_PROC_XARM_FREQUENCY_DQ

10135

Silent run

2019/08/28 07:54-09:07

1250981658 - 1250986038

FPMI

K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ

10168

Silent run

2019/08/29 07:43-08:46

1251067398 - 1251071178

FPMI

K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ (Some bug)

10168

Silent run

Note for beginner

  • Time
    • JST or GPS time
  • IFO config = Interferometer configuration
    • Yarm cavity : Lock the Yarm cavity by feedback to the IMC length (Almost frequency + Yarm length noise)
    • FPMI : Fabry-Perot Michelson interferometer. The h-of-t signal is calculated from DARM displacement
  • Main channel
    • We should analyze this channel as h(t) channel
    • K1:CAL-CS_PROC_XARM_FREQUENCY_DQ
      • Unit is Hz, because of calculating the IR laser frequency noise
    • K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ
      • DARM displacement [nm or m] there are still some bugs in the online model, I will summarize later
  • klog
    • Information related to the run is summarized here
  • Memo
    • What is this?
    • In the future, we want to do the calibration line injection, PEM injection, add the excitation and check the noise, hardware injection, and so on.
    • We will write following information.

KAGRA/Subgroups/DET/RUN/MORNINGRUN2019 (last edited 2019-11-21 14:05:15 by chihiro.kozakai)