Line 21: Line 21:
   * Even though Yarm lock, the channel name is XARM. The same strategy to keep the cavity.

Summary of the morning run

Time (JST)

Time (GPS)

IFO config

Main channel

klog

Memo

2019/08/27 02:09-09:26

1250874558 - 1250900778

Yarm cavity

K1:CAL-CS_PROC_XARM_FREQUENCY_DQ

10135

Silent run

2019/08/28 07:54-09:07

1250981658 - 1250986038

FPMI

K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ

10168

Silent run

2019/08/29 07:43-08:46

1251067398 - 1251071178

FPMI

K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ (Some bug)

10184

Silent run

Note for beginner

  • Time
    • JST or GPS time
  • IFO config = Interferometer configuration
    • Yarm cavity : Lock the Yarm cavity by feedback to the IMC length (Almost frequency noise evaluated by Yarm length)
    • FPMI : Fabry-Perot Michelson interferometer. The h-of-t signal is calculated from DARM displacement
  • Main channel
    • We should analyze this channel as h(t) channel
    • K1:CAL-CS_PROC_XARM_FREQUENCY_DQ
      • Unit is Hz, because of calculating the IR laser frequency noise
      • Even though Yarm lock, the channel name is XARM. The same strategy to keep the cavity.
    • K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ
      • DARM displacement [nm or m] there are still some bugs in the online model, I will summarize later
  • klog
    • Information related to the run is summarized here
  • Memo
    • What is this?
    • In the future, we want to do the calibration line injection, PEM injection, add the excitation and check the noise, hardware injection, and so on.
    • We will write following information.

KAGRA/Subgroups/DET/RUN/MORNINGRUN2019 (last edited 2019-11-21 14:05:15 by chihiro.kozakai)