Size: 935
Comment:
|
Size: 1750
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 3: | Line 3: |
|| Time (JST) || Time (GPS) || IFO config || Main channel || klog || Memo || || 2019/08/27 02:09-09:26 || 1250874558 - 1250900778 || Yarm cavity || K1:CAL-CS_PROC_XARM_FREQUENCY_DQ || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10135|10135]] || Silent run || || 2019/08/28 07:54-09:07 || 1250981658 - 1250986038 || FPmi || K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10168|10168]] || Silent run || |
|| Time (JST) || Time (GPS) || IFO config || Main channel || klog || Memo || || 2019/08/27 02:09-09:26 || 1250874558 - 1250900778 || Yarm cavity || K1:CAL-CS_PROC_XARM_FREQUENCY_DQ || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10135|10135]] || Silent run || || 2019/08/28 07:54-09:07 || 1250981658 - 1250986038 || FPMI || K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10168|10168]] || Silent run || || 2019/08/29 07:43-08:46 || 1251067398 - 1251071178 || FPMI || K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ (Some bug) || [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=10168|10168]] || Silent run || |
Line 7: | Line 8: |
== Note for beginner ==; |
=== Note for beginner === |
Line 14: | Line 14: |
* Yarm cavity or FPmi(Fabry-Perot Michelson intereferometer) | * Yarm cavity : Lock the Yarm cavity by feedback to the IMC length (Almost frequency + Yarm length noise) * FPMI : Fabry-Perot Michelson interferometer. The h-of-t signal is calculated from DARM displacement |
Line 18: | Line 19: |
* K1:CAL-CS_PROC_XARM_FREQUENCY_DQ * Unit is Hz, because of calculating the IR laser frequency noise * K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ * DARM displacement [nm or m] there are still some bugs in the online model, I will summarize later |
|
Line 24: | Line 29: |
* In the future, we want to do the calibration line injection, PEM injection, add the excitation and check the noise, hardware injection, and so on. * We will write following information. |
Summary of the morning run
Time (JST) |
Time (GPS) |
IFO config |
Main channel |
klog |
Memo |
2019/08/27 02:09-09:26 |
1250874558 - 1250900778 |
Yarm cavity |
K1:CAL-CS_PROC_XARM_FREQUENCY_DQ |
Silent run |
|
2019/08/28 07:54-09:07 |
1250981658 - 1250986038 |
FPMI |
K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ |
Silent run |
|
2019/08/29 07:43-08:46 |
1251067398 - 1251071178 |
FPMI |
K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ (Some bug) |
Silent run |
Note for beginner
- Time
- JST or GPS time
- IFO config = Interferometer configuration
- Yarm cavity : Lock the Yarm cavity by feedback to the IMC length (Almost frequency + Yarm length noise)
- FPMI : Fabry-Perot Michelson interferometer. The h-of-t signal is calculated from DARM displacement
- Main channel
- We should analyze this channel as h(t) channel
- K1:CAL-CS_PROC_XARM_FREQUENCY_DQ
- Unit is Hz, because of calculating the IR laser frequency noise
- K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ
- DARM displacement [nm or m] there are still some bugs in the online model, I will summarize later
- klog
- Information related to the run is summarized here
- Memo
- What is this?
- In the future, we want to do the calibration line injection, PEM injection, add the excitation and check the noise, hardware injection, and so on.
- We will write following information.