⇤ ← Revision 1 as of 2020-11-16 16:14:32
Size: 1289
Comment:
|
Size: 1402
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 41: | Line 41: |
{{{ MEDM: sitemap - CDS - CDS The little button next to the CFC. Press the [Admin only]-[start awgtpan] }}} |
DGS Daily Operations
Checking and recovering status
- All DAQ statuses must be green.
MEDM sitemap - CDS - CDS
- If it's red, follow these steps to recover.
FE Status
TIM Status
MEDM: sitemap - CDS - CDS Press the ICU button in the red area to reset it.
ADC Status
MEDM: sitemap - CDS - CDS Press the ICU button in the red area to reset it.
DAC Status
DAQ Status
MEDM: sitemap - CDS - DAQ Status - !mx_stream - restart
- If it doesn't turn green, log in to each real time calculator and recover.
$ ssh k1xxx ... k1xxx$ sudo /etc/init.d/mx_stream status
- If it's stopped.
k1xxx$ sudo /etc/init.d/mx_stream restart
IPC Status
MEDM: sitemap - CDS - CDS Press the ICU button in the red area to reset it.
AUG Status
MEDM: sitemap - CDS - CDS The little button next to the CFC. Press the [Admin only]-[start awgtpan]
DK/EXC/OVF/CFC Status
- User side issues.
- Check that the RCGVersion matches the system.
MEDM sitemap - CDS - CDS - k1xxx Check the display [RCG # x.xx].
- There is a problem with the model build. Check the modified model for problems.
- VIS: the next operation might be able to restore it.