DGS Daily Operations
Checking and recovering status
- All DAQ statuses must be green.
MEDM sitemap - CDS - CDS
- If it's red, follow these steps to recover.
FE Status
Set BURT_RESTORE to 1 $ caput K1:FEC-xx_BURT_RESTORE 1
If it doesn't work, set it to 1 again right after rebooting the model.
TIM Status
MEDM: sitemap - CDS - CDS Press the ICU button in the red area to reset it.
ADC Status
MEDM: sitemap - CDS - CDS Press the ICU button in the red area to reset it.
DAC Status
DAQ Status
MEDM: sitemap - CDS - DAQ Status - !mx_stream - restart
- If it doesn't turn green, log in to each real time calculator and recover.
$ ssh k1xxx ... k1xxx$ sudo /etc/init.d/mx_stream status
- If it's stopped.
k1xxx$ sudo /etc/init.d/mx_stream restart
IPC Status
MEDM: sitemap - CDS - CDS Press the DCU button in the red area to reset it.
If that doesn't solve the problem, see K-Log16327
AWG Status
MEDM: sitemap - CDS - CDS The little button next to the CFC. Press the [Admin only]-[start awgtpan]
DK/EXC/OVF/CFC Status
- User side issues.
- Check that the RCGVersion matches the system.
MEDM sitemap - CDS - CDS - k1xxx Check the display [RCG # x.xx].
- There is a problem with the model build. Check the modified model for problems.
- VIS: the next operation might be able to restore it.