Differences between revisions 1 and 9 (spanning 8 versions)
Revision 1 as of 2011-02-03 11:23:37
Size: 1994
Editor: NaokoOhishi
Comment:
Revision 9 as of 2011-12-07 10:53:09
Size: 3962
Comment:
Deletions are marked like this. Additions are marked like this.
Line 13: Line 13:
||D-sub 9pinケーブル||(0.5m,1m,2m,5m,10m)||各20本|| || ||D-sub 9pinケーブル||(0.5m,1m,2m,5m,10m)||各20本||[[LCGT/subgroup/ifo/digital/Distribution/Dsub9|D-subケーブルの仕様]] ||
Line 15: Line 15:
== 立ち上げ ==
== Connection ==

 * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=404|D1100404]]: Network diagram of standalone Real-Time system at Kamioka (3/28/2011)


== Delivered PCs ==

||Name||Vender||Part No.||Serial No.||Current location||Date||Responsible person||Attachment||
|| || || || || || || || ||
||standalone4 RT||Super Micro(Visual Technology)||VT64 Server9500 X-15||113429||NAOJ, TAMA||2011/12/6||Hayama||Power cable x2, rack mount kit||
||standalone4 WS||DELL||T3500||CWBTVBX||NAOJ, TAMA||2011/12/6||Hayama||Mouse, keyboard, Mini-DVI to DVI x2, Power cable||
||23 inch monitor||MITSUBISHI||RDT233WLM-D||11201783AJ||NAOJ, TAMA||2011/12/6||Hayama||Power cable, D-SUB cable||
||23 inch monitor||MITSUBISHI||RDT233WLM-D||11201781AJ||NAOJ, TAMA||2011/12/6||Hayama||Power cable, D-SUB cable||
||ADC||General Standards||PMC66-16AI64SSA-64-50MHz-No IO|| ||NAOJ, TAMA||2011/12/6||Hayama|| ||
||PMC to PCIe adapter||General Standards||PCIe-PMC000||091 103-15||NAOJ, TAMA||2011/12/6||Hayama||Long internal power cable||
||Wireless LAN Router||Buffalo||WZR-HP-G301NH||46638410130745G||NAOJ, TAMA||2011/12/6||Hayama||AC adapter||

-----

== FAQ ==

 * network adapterの設定
  * Ubuntu上で{{{
> ifconfig
}}} で確認。network interface名が本来eth0から始まらなければならないが、eth1-eth2とか変になってしまう。これは{{{
/etc/udev/rules.d/70-persistent-net.rules
}}} をいじることで解決。無事にeth0,eth1となった。いぜん別のPCで設定されたHDDをそのままコピーして移したので、以前のMACアドレスが残ってしまったのが原因だ。

-----
== How to ==
=== ハードウエアの立ち上げ ===
Line 19: Line 50:
1. サーバに電源等をつないでスイッチを入れてみる<<BR>> 1. サーバに電源等をつないでスイッチを入れる<<BR>>
Line 28: Line 59:
3. ADC, DACを拡張ボックスに差す
Line 31: Line 63:
あるいは>/sbin/lspciとしたとき、拡張ボックスが接続されていないときと違うメッセージが出ることを確認する。

3.

== FAQ ==
あるいは>/sbin/lspciとすると、ボードがハードとして認識されていれば、
{{{
15:000 PCI bridge: PLX Technology, Inc. PEX8112 x1 Lane PCI Express-to-PCI Bridge (rev aa)
16:00.0 Bridge: PLX Technology, Inc. PCI9056 32-bit 66MHz PCI <-> IOBus Bridge (rev ac)
}}}
などと表示される。

デジタルシステムの配布

2011年度に、5組のデジタルシステムをサブグループに配布する。

購入品リスト

数量は1組あたり

型式(メーカー)

数量

備考

サーバー

1

拡張ボックス

OSS-PCIe-4U-EXP-2001-700(One Stop Systems, Inc)

1

ADC

DAC

DIO

DO-32LPE(contec)

4

D-sub 9pinケーブル

(0.5m,1m,2m,5m,10m)

各20本

D-subケーブルの仕様

ディスプレイ

Diamondcrysta WIDE RDT233WLM-D(三菱)

3

Connection

  • D1100404: Network diagram of standalone Real-Time system at Kamioka (3/28/2011)

Delivered PCs

Name

Vender

Part No.

Serial No.

Current location

Date

Responsible person

Attachment

standalone4 RT

Super Micro(Visual Technology)

VT64 Server9500 X-15

113429

NAOJ, TAMA

2011/12/6

Hayama

Power cable x2, rack mount kit

standalone4 WS

DELL

T3500

CWBTVBX

NAOJ, TAMA

2011/12/6

Hayama

Mouse, keyboard, Mini-DVI to DVI x2, Power cable

23 inch monitor

MITSUBISHI

RDT233WLM-D

11201783AJ

NAOJ, TAMA

2011/12/6

Hayama

Power cable, D-SUB cable

23 inch monitor

MITSUBISHI

RDT233WLM-D

11201781AJ

NAOJ, TAMA

2011/12/6

Hayama

Power cable, D-SUB cable

ADC

General Standards

PMC66-16AI64SSA-64-50MHz-No IO

NAOJ, TAMA

2011/12/6

Hayama

PMC to PCIe adapter

General Standards

PCIe-PMC000

091 103-15

NAOJ, TAMA

2011/12/6

Hayama

Long internal power cable

Wireless LAN Router

Buffalo

WZR-HP-G301NH

46638410130745G

NAOJ, TAMA

2011/12/6

Hayama

AC adapter


FAQ

  • network adapterの設定
    • Ubuntu上で

      > ifconfig

      で確認。network interface名が本来eth0から始まらなければならないが、eth1-eth2とか変になってしまう。これは

      /etc/udev/rules.d/70-persistent-net.rules
      をいじることで解決。無事にeth0,eth1となった。いぜん別のPCで設定されたHDDをそのままコピーして移したので、以前のMACアドレスが残ってしまったのが原因だ。


How to

ハードウエアの立ち上げ

配布物品リストを確認。

1. サーバに電源等をつないでスイッチを入れる。
サーバーに専用の(付属でないものでは動かないかもしれない)電源線を2本つなぐ。ディスプレイ、キーボード、マウスも接続する。
起動してみて、ピーという音がずっとしていたり、Uというマークのランプが点滅している場合は、電源のエラー。

2. 拡張ボックスを接続してみる
次に、拡張ボックスとサーバを専用線で(AとBがあるが、とりあえずBに)接続し、 拡張ボックス付属の電源線(これも専用でないと動かないかもしれない)もつなぐ。 サーバーの電源を入れたときに、前面パネルの緑色LEDが点灯し、ファンも回っていることを確認する。

3. ADC, DACを拡張ボックスに差す

>lspci

あるいは>/sbin/lspciとすると、ボードがハードとして認識されていれば、

15:000 PCI bridge: PLX Technology, Inc. PEX8112 x1 Lane PCI Express-to-PCI Bridge (rev aa)
16:00.0 Bridge: PLX Technology, Inc. PCI9056 32-bit 66MHz PCI <-> IOBus Bridge (rev ac)

などと表示される。

KAGRA/Subgroups/DGS/Projects/STDA (last edited 2013-06-07 09:14:00 by OsamuMiyakawa)