Differences between revisions 2 and 137 (spanning 135 versions)
Revision 2 as of 2019-12-01 16:05:11
Size: 92
Editor: miyoki
Comment:
Revision 137 as of 2023-06-30 14:42:10
Size: 8285
Editor: miyoki
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
Test page == [1] Clean booth ==
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3599 | Laser Room]]
 * [[ https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3588 | PR-area (including MCF-IFI-MMT-PRM-PR3) & BS-area (including PR2, BS, SR2) & EXC, EYC]]
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6447 | SR-area (including SR3, SRM, OMC) & I(XY)C & I(XY)V ]]
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12521 | I(XY)A ]]
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12522 | Pre-Clean Room for PSL/PR-area ]]
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12523| Kotohira FFU ULPA for mainly IEXYA, IEXYV]]
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12524 | MAC-2A-251DC-ULS-(dial) ]]
Line 3: Line 10:
'''Enter Alignment Mode1''' == [2] Heat Generators ==
=== Corner ===
|| |||| Items |||| O4a |||| June/30 |||| ||
|| IXV |||| Air conditioner |||| x (weak, 20C) |||| o (strong, 20C) |||| ||
|| |||| Delongho Heater |||| x |||| o L3 |||| ||
|| |||| Ceiling Lights |||| o |||| o |||| ||
|| |||| TMP/Scrolls |||| x |||| o |||| ||
|| |||| Ion Pump |||| o |||| x |||| ||
|| |||| FFUs |||| 2 |||| 2 |||| ||
Line 5: Line 20:
* Go to Commissioning.Doc.
* Select LSC_Lock.
|| |||| Items |||| O4a |||| June/30 |||| ||
|| IYV |||| Air conditioner |||| o (weak, 20C) |||| o (weak, 20C) |||| ||
|| |||| Delongho Heater |||| o L4 |||| o L1 |||| ||
|| |||| Ceiling Lights |||| o |||| o |||| ||
|| |||| TMP/Scrolls |||| x |||| o |||| ||
|| |||| Ion Pump |||| o |||| x |||| ||
|| |||| FFUs |||| 2 |||| 2 |||| ||

|| |||| Items |||| O4a |||| June/30 |||| ||
|| Corner 1F |||| Precision Cooler |||| o(19.00) |||| o(19.00) |||| ||
|| |||| Daikin Cooler MCF-C |||| x |||| x |||| ||
|| |||| Daikin Cooler BS-C |||| x |||| o |||| ||
|| |||| Daikin Cooler SR-C |||| x |||| x |||| ||
|| |||| Daikin Cooler IYC-C |||| x |||| x |||| ||
|| |||| Ceiling Lights A |||| 1/2 |||| 1/2 |||| ||
|| |||| Ceiling Lights B |||| 1/2 |||| 1/2 |||| ||
|| |||| Ceiling Lights C |||| 1/1 |||| 1/1 |||| ||
|| |||| Ceiling Lights IXC |||| 1/2 |||| 1/2 |||| ||
|| |||| Ceiling Lights IXA |||| 1/1 |||| 1/1 |||| ||
|| |||| Ceiling Lights IYC |||| 1/2 |||| 1/2 |||| ||
|| |||| Ceiling Lights IYA |||| 1/1 |||| 1/1 |||| ||
|| |||| Sunrise Heater BS |||| x |||| x |||| ||
|| |||| Sunrise Heater SR2 |||| x |||| x |||| ||
|| |||| Sunrise Heater OMC |||| x |||| x |||| ||
|| |||| Sunrise Heater PR2 |||| x |||| x |||| ||
|| |||| Sunrise Heater DGS |||| x |||| x |||| ||
|| |||| Delonghi Heater MCF |||| o L2 |||| x |||| ||
|| |||| FFUs |||| ?? |||| ?? |||| ||

|| |||| Items |||| O4a |||| June/30 |||| ||
|| PSL Room |||| Precision Cooler #1 |||| o |||| o |||| ||
|| |||| Precision Cooler #2 |||| x |||| x |||| ||

|| |||| Items |||| O4a |||| June/30 |||| ||
|| IXC |||| TMP/Scrolls |||| 3 x |||| 3 o |||| ||
|| |||| Ion Pump |||| 2 o |||| 2 x |||| ||
|| |||| Duct Shield Cooler |||| 2 o |||| 2 x |||| ||
|| |||| Radiation Shield Cooler |||| 2 x |||| 2 x |||| ||
|| |||| Payload Cooler |||| 2 x |||| 2 x |||| ||
|| |||| FFUs |||| ?? |||| ?? |||| ||
|| |||| KAOCHs |||| zero |||| zero |||| ||

|| |||| Items |||| O4a |||| June/30 |||| ||
|| IYC |||| TMP/Scrolls |||| 3 x |||| 3 o |||| ||
|| |||| Ion Pump |||| 2 o |||| 2 x |||| ||
|| |||| Duct Shield Cooler |||| 2 o |||| 2 x |||| ||
|| |||| Radiation Shield Cooler |||| 2 x |||| 2 x |||| ||
|| |||| Payload Cooler |||| 2 x |||| 2 x |||| ||
|| |||| FFUs |||| ?? |||| ?? |||| ||
|| |||| KAOCHs |||| zero |||| zero |||| ||

|| |||| Items |||| O4a |||| June/30 |||| ||
|| IXA |||| TMP/Scrolls |||| x |||| x |||| ||
|| |||| FFUs |||| ?? |||| ?? |||| ||

|| |||| Items |||| O4a |||| June/30 |||| ||
|| IYA |||| TMP/Scrolls |||| x |||| o |||| ||
|| |||| FFUs |||| ?? |||| ?? |||| ||

=== EX ===

|| |||| Items |||| O4a |||| |||| ||
|| EX 1F |||| Air conditioner 1 |||| x |||| |||| ||
|| |||| Air conditioner 2 |||| x |||| |||| ||
|| |||| Ceiling Lights |||| 0/1 |||| |||| ||

|| |||| Items |||| O4a |||| |||| ||
|| EXC |||| TMP/Scrolls |||| 3 x |||| |||| ||
|| |||| Ion Pump |||| 2 o |||| |||| ||
|| |||| Duct Shield Cooler |||| 2 o |||| |||| ||
|| |||| Radiation Shield Cooler |||| 2 o |||| |||| ||
|| |||| Payload Cooler |||| 2 x |||| |||| ||
|| |||| FFUs |||| ?? |||| |||| ||
|| |||| KAOCHs |||| zero |||| |||| ||

|| |||| Items |||| O4a |||| |||| ||
|| EXA |||| TMP/Scrolls |||| 1x |||| |||| ||
|| |||| Ion Pump |||| 1o |||| |||| ||
|| |||| FFUs |||| ?? |||| |||| ||
|| |||| Ceiling Lights |||| 1/1 |||| |||| ||

|| |||| Items |||| O4a |||| |||| ||
|| EXV |||| Air conditioner |||| x |||| |||| ||
|| |||| Delongho Heater |||| o L3 |||| |||| ||
|| |||| Ceiling Lights |||| x |||| |||| ||
|| |||| TMP/Scrolls |||| x |||| |||| ||
|| |||| Ion Pump |||| o |||| |||| ||
|| |||| FFUs |||| 1 |||| |||| ||

=== EY ===

|| |||| Items |||| O4a |||| June/29 |||| ||
|| EY 1F |||| Air conditioner |||| x |||| x |||| ||
|| |||| Ceiling Lights |||| 1/1 |||| 1/1 |||| ||
|| |||| Delonghi Heater 1 |||| o L5 |||| o L2 |||| ||
|| |||| Sunrise Heater 1 |||| o L3 |||| o L1 |||| ||
|| |||| Sunrise Heater 2 |||| o L3 |||| o L2 |||| ||

|| |||| Items |||| O4a |||| June/29 |||| ||
|| EYC |||| TMP/Scrolls |||| 4x |||| 3o, 1x |||| ||
|| |||| Ion Pump |||| 2o |||| 2x |||| ||
|| |||| Duct Shield Cooler |||| 2o |||| 1x, 1o |||| ||
|| |||| Radiation Shield Cooler |||| 2x |||| 2x |||| ||
|| |||| Payload Cooler |||| 2x |||| 2x |||| ||
|| |||| FFUs |||| 13 |||| 13 |||| ||
|| |||| KAOCHs |||| zero |||| zero |||| ||

|| |||| Items |||| O4a |||| June/29 |||| ||
|| EXA |||| TMP/Scrolls |||| 1x |||| 1o |||| ||
|| |||| FFUs |||| 5/10 |||| 2/10 |||| ||
|| |||| Ceiling Lights |||| 1/1 |||| 1/1 |||| ||

|| |||| Items |||| O4a |||| June/29 |||| ||
|| EYV |||| Air conditioner |||| x |||| x |||| ||
|| |||| Sunrise Heater |||| o L2 |||| o L2 |||| ||
|| |||| Ceiling Lights |||| x |||| x |||| ||
|| |||| TMP/Scrolls |||| 1 x |||| 1 o |||| ||
|| |||| Ion Pump |||| o |||| x |||| ||
|| |||| FFUs |||| 1 |||| 1 |||| ||

[1] Clean booth

[2] Heat Generators

Corner

Items

O4a

June/30

IXV

Air conditioner

x (weak, 20C)

o (strong, 20C)

Delongho Heater

x

o L3

Ceiling Lights

o

o

TMP/Scrolls

x

o

Ion Pump

o

x

FFUs

2

2

Items

O4a

June/30

IYV

Air conditioner

o (weak, 20C)

o (weak, 20C)

Delongho Heater

o L4

o L1

Ceiling Lights

o

o

TMP/Scrolls

x

o

Ion Pump

o

x

FFUs

2

2

Items

O4a

June/30

Corner 1F

Precision Cooler

o(19.00)

o(19.00)

Daikin Cooler MCF-C

x

x

Daikin Cooler BS-C

x

o

Daikin Cooler SR-C

x

x

Daikin Cooler IYC-C

x

x

Ceiling Lights A

1/2

1/2

Ceiling Lights B

1/2

1/2

Ceiling Lights C

1/1

1/1

Ceiling Lights IXC

1/2

1/2

Ceiling Lights IXA

1/1

1/1

Ceiling Lights IYC

1/2

1/2

Ceiling Lights IYA

1/1

1/1

Sunrise Heater BS

x

x

Sunrise Heater SR2

x

x

Sunrise Heater OMC

x

x

Sunrise Heater PR2

x

x

Sunrise Heater DGS

x

x

Delonghi Heater MCF

o L2

x

FFUs

??

??

Items

O4a

June/30

PSL Room

Precision Cooler #1

o

o

Precision Cooler #2

x

x

Items

O4a

June/30

IXC

TMP/Scrolls

3 x

3 o

Ion Pump

2 o

2 x

Duct Shield Cooler

2 o

2 x

Radiation Shield Cooler

2 x

2 x

Payload Cooler

2 x

2 x

FFUs

??

??

KAOCHs

zero

zero

Items

O4a

June/30

IYC

TMP/Scrolls

3 x

3 o

Ion Pump

2 o

2 x

Duct Shield Cooler

2 o

2 x

Radiation Shield Cooler

2 x

2 x

Payload Cooler

2 x

2 x

FFUs

??

??

KAOCHs

zero

zero

Items

O4a

June/30

IXA

TMP/Scrolls

x

x

FFUs

??

??

Items

O4a

June/30

IYA

TMP/Scrolls

x

o

FFUs

??

??

EX

Items

O4a

EX 1F

Air conditioner 1

x

Air conditioner 2

x

Ceiling Lights

0/1

Items

O4a

EXC

TMP/Scrolls

3 x

Ion Pump

2 o

Duct Shield Cooler

2 o

Radiation Shield Cooler

2 o

Payload Cooler

2 x

FFUs

??

KAOCHs

zero

Items

O4a

EXA

TMP/Scrolls

1x

Ion Pump

1o

FFUs

??

Ceiling Lights

1/1

Items

O4a

EXV

Air conditioner

x

Delongho Heater

o L3

Ceiling Lights

x

TMP/Scrolls

x

Ion Pump

o

FFUs

1

EY

Items

O4a

June/29

EY 1F

Air conditioner

x

x

Ceiling Lights

1/1

1/1

Delonghi Heater 1

o L5

o L2

Sunrise Heater 1

o L3

o L1

Sunrise Heater 2

o L3

o L2

Items

O4a

June/29

EYC

TMP/Scrolls

4x

3o, 1x

Ion Pump

2o

2x

Duct Shield Cooler

2o

1x, 1o

Radiation Shield Cooler

2x

2x

Payload Cooler

2x

2x

FFUs

13

13

KAOCHs

zero

zero

Items

O4a

June/29

EXA

TMP/Scrolls

1x

1o

FFUs

5/10

2/10

Ceiling Lights

1/1

1/1

Items

O4a

June/29

EYV

Air conditioner

x

x

Sunrise Heater

o L2

o L2

Ceiling Lights

x

x

TMP/Scrolls

1 x

1 o

Ion Pump

o

x

FFUs

1

1

KAGRA/Subgroups/FCL (last edited 2023-12-28 08:01:30 by miyoki)